All Aluminium Alloy Conductor
Product Description
Specifications
Aluminum alloy bare stranded conductor
1. overhead power line transmission
2. various voltage levels
3. fast delivery
AAAC Steel cored aluminium alloy stranded conductor
1. Standard: BS EN50182,ASTM B398, ASTM B399, BS 3242 DIN 48201, CSA C49, NFC 34-125
2.Specification: AAAC are composed by bare concentric-lay-stranded aluminum alloy wires.
3. Application: AAAC are used in overhead electric power transmission and distribution lines.
4.AAAC Construction and Specification for your reference
Nominal Cross-sectional Area (mm2) | Numbers/Diameter (mm) |
Calculated Cross-sectional Area (mm2) | Overall Diameter (mm) |
Max. D.C Resistance (Ω/km) |
CalculatedBreaking Load (N) |
Calculated Weight (kg/km) |
Min. Delivery Length (m) |
Current (A) |
16 | 7/1.70 | 15.89 | 5.10 | 1.802 | 2840 | 43.5 | 4000 | 111 |
25 | 7/2.15 | 25.41 | 6.45 | 1.127 | 4355 | 69.6 | 3000 | 147 |
35 | 7/2.50 | 34.36 | 7.50 | 0.8382 | 5760 | 94.1 | 2000 | 180 |
50 | 7/3.00 | 49.48 | 9.00 | 0.5786 | 7930 | 135.5 | 1500 | 227 |
70 | 7/3.60 | 71.25 | 10.80 | 0.4018 | 10950 | 195.1 | 1250 | 284 |
95 | 7/4.16 | 95.14 | 12.48 | 0.3009 | 14450 | 260.5 | 1250 | 338 |
120 | 19/2.85 | 121.21 | 14.25 | 0.2373 | 19420 | 333.5 | 1250 | 390 |
150 | 19/3.15 | 148.07 | 15.75 | 0.1943 | 23310 | 407.4 | 1250 | 454 |
185 | 19/3.50 | 182.80 | 17.50 | 0.1574 | 28440 | 503.0 | 1000 | 518 |
210 | 19/3.75 | 209.85 | 18.75 | 0.1371 | 32260 | 577.4 | 1000 | 575 |
240 | 19/4.00 | 238.76 | 20.00 | 0.1205 | 36260 | 656.9 | 1000 | 610 |
300 | 37/3.20 | 297.83 | 22.40 | 0.09689 | 46850 | 820.4 | 1000 | 707 |
400 | 37/3.70 | 397.83 | 25.90 | 0.07247 | 61150 | 1097 | 1000 | 851 |
500 | 37/4.16 | 502.90 | 29.12 | 0.05733 | 76370 | 1387 | 1000 | 982 |
630 | 61/3.63 | 631.30 | 32.67 | 0.04577 | 91940 | 1744 | 800 | 1140 |
800 | 61/4.10 | 805.36 | 36.90 | 0.03588 | 115900 | 2255 | 800 | 1340 |
Item L.p. |
Opis Rated data/Technical parameters |
Jednostka Unit |
Warto Value |
||
AlMgSi stranded compacted conductor | |||||
1. | Producent Manufacturer |
– | |||
2. | Wykonano zgodnie z Manufacturer according to |
EN 60228 | |||
3. | Oznaczenie przewodu Conductor identification |
– | 50 | 54,6 | 95 |
4. | Nominalna rednica przewodu Nominal conductor diameter |
mm | 7,85 – 8,20 | 9,20 – 9,55 | 11,4±0,3 |
5. | Nominalny przekrój przewodu Nominal cross-section |
2 | 50 | 54,6 | 95 |
6. | Liczba drutów (konstrukcja) Number of wires |
szt. psc |
1+6 | ||
7. | Kierunek skrtu poszczególnych warstw Direction of each layer |
– | (Z) | ||
8. | Obliczeniowy modu sprystoci wzdunej (kocowy) przewodu Calculated elastic modulus (final) of the conductor |
N/mm2 | 60 000 | ||
9. | Obliczeniowy wspóczynnik wyduenia cieplnego przewodu Calculated thermal elongation coefficient of the conductor |
× 10-6 K-1 | 23,00 | ||
10. | Max. rezystancja DC 1 km przewodu w temp. 20 C Max. DC resistance of 1 km of conductor at 20 C |
Ω/km | 0,72 | 0,63 | 0,363 |
11. | Min znamionowa wytrzymao przewodu na rozciganie RTS Min. rated tensile strength of the conductor (RTS) (breaking force) |
kN |
14,2 |
16,6 |
27,9 |
12. | Przybliona masa 1 km przewodu Approx. weight of 1 km of conductor |
kg/km | 130,03 | 165,8 | 248,28 |
Contact Information:
Daiana/ Marketing Manager
Henan Jiapu Cable Co., Ltd
Direct Tel: +86-371-55367868 Ext.611
Direct Fax: +86-371-55367870
Mobile No.: +86-18339931106
website: jiapucable
Contact us
Similar Or Related
-
XLPE Insulated Aerial Service Drop Cable Conductor #3AWG Duplex ICEA S-66-524 NEMA WC7
-
WIRE QUADRUPLEX 2/0AWG Thoroughbred 6201 ALLOY NEUTRAL MESSENGER
-
WIRE QUADRUPLEX 6AWG French COACH 6201 ALLOY NEUTRAL MESSENGER
-
HDPE Insulated ACSR Conductor 4/0AWG 15kV Tree Wire for Distribution Lines
-