Aerial Bundle Cable Triplex AAAC Bare Neutral Conductor 2/0 AWG

Aerial Bundle Cable Triplex AAAC Bare Neutral Conductor 2/0 AWG
JKLYJ
Insulated
Stranded
Overhead
Aluminum
Crosslinking
XLPE
Round Wire
Power Transmission
ISO9001, CE, CCC
Yifang Cable
Black
2+1
YIFANG
Drums, Coils or According to Customers' Request
1.5mm2-1000mm2
China
8544492100

Product Description

Aerial Bundle Cable Triplex AAAC Bare Neutral Conductor 2/0 AWG

Product Details:
Insulation Material XLPE
Type Low Voltage
Conductor Material Aluminum
Jacket NON SHEATH
Application Overhead
Place of Origin Henan China
Brand Name YIFANG
Model Number DUPLEX, TRIPLEX, QUADRUPLEX

Service Drop Cable
1. Application of Service Drop Cable:
Service Drop Cable(ABC CABLE) are mainly used for electric power transmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.

2. Type of Service Drop Cable:
Service Drop Cable(ABC CABLE) covers mainly three types:
Duplex Service Drop
Triplex Service Drop
Quadruplex Service Drop

The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers.

3. Detaild Introduction of Service Drop Cable
3.1 Duplex Service Drop

Applications
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.

Construction
Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger.

3.2 Triplex Service Drop
Applications
To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.

Construction
Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger.

3.3 Quadruplex Service Drop
Applications
Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.

Construction
Conductors are concentrically standed, compressed 1350-H19 aluminium. Insulated with either polyethylene or XLPE. Neutral messengers aer concentrically stranded 6210 AAAC, AAC or ACSR.

DUPLEX
ABC
ABC
code (AAAC)
word
AWG or kcmil kcmil mm2 Ips cmil mm2 in mils mm
Chihuahua 1*6AWG+1*30.58 7 30.58 15.495 1.68 5.04 1110 1 26240 13.3 4.11 4.11 45 1.14 6.40 11.44
Vizsla 1*6AWG+1*30.58 7 30.58 15.495 1.68 5.04 1110 7 0.0612 1.5545 4.66 45 1.14 6.95 11.99
Harrier 1*4AWG+1*48.69 7 48.69 24.672 2.12 6.36 1760 1 41740 21.15 5.19 5.19 45 1.14 7.48 13.84
Whippet 1*4AWG+1*48.69 7 48.69 24.672 2.12 6.36 1760 7 0.0772 1.9609 5.88 45 1.14 8.17 14.53
Schnauzer 1*2AWG+1*77.47 7 77.47 39.255 2.67 8.02 2800 7 0.0974 2.474 7.42 45 1.14 9.71 17.73
Heeler 1*1/0AWG+1*123.3 7 123.3 62.477 3.37 10.11 4460 19 105600 53.51 1.89 9.47 60 1.52 12.52 22.63
Class 2 stranded conductors for single-core and multi-core cables
Nominal crosssectional area Minimum number of wires in the conductor Maximum resistance of conductor at 20ºC
Circular Circular compacted Shaped Annealed copper conductor Aluminium or aluminium alloy conductor
Cu Al Cu Al Cu Al Plain wires Metal-coated wires
mm2 Ω/KM Ω/KM Ω/KM
0.5 7 36 36.7
0.75 7 24.5 24.8
1 7 18.1 18.2
1.5 7 6 12.1 12.2
2.5 7 6 7.41 7.58
4 7 6 4.61 4.7
6 7 6 3.08 3.11
10 7 7 6 6 1.83 1.84 3.08
16 7 7 6 6 1.15 1.16 1.91
25 7 7 6 6 6 6 0.727 0.734 1.2
35 7 7 6 6 6 6 0.524 0.529 0.868
50 19 19 6 6 6 6 0.387 0.391 0.641
70 19 19 12 12 12 12 0.268 0.27 0.443
95 19 19 15 15 15 15 0.193 0.195 0.32
120 37 37 18 15 18 15 0.153 0.154 0.253
150 37 37 18 15 18 15 0.124 0.126 0.206
185 37 37 30 30 30 30 0.0991 0.1 0.164
240 37 37 34 30 34 30 0.0754 0.0762 0.125
300 61 61 34 30 34 30 0.0601 0.0607 0.1
400 61 61 53 53 53 53 0.047 0.0475 0.0778
500 61 61 53 53 53 53 0.0368 0.0369 0.0605
630 91 91 53 53 53 53 0.0283 0.0286 0.0469
800 91 91 53 53 0.0221 0.0224 0.0367
1000 91 91 53 53 0.0176 0.0177 0.0291