Aerial Bundle Cable ABC Aerial Overhead Cable with ACSR Messenger Core
More product about ABC CableAerial Bundle Cable ABC Aerial Overhead Cable with ACSR Messenger Core
AERIAL BUNDLE CABLE
Jinyuan
ISO9001, CE, CCC, RoHS
Oveahead
Round Wire
XLPE
No
Aluminum
Overhead, Underground
Stranded
Insulated
LV. Mv. Hv
as Per Your Customers ' Request
PVC/PE/XLPE
Jinyuan
All Wooden, Steel Wooden or Steel Package
China
8544492100
Product Description
ABC Aerial overhead cable with ACSR messenger Core
ABC cable is suitable for transmitting line and distributing line of rated voltage 0.6/1KV and others.It is widely used at tall buildings,traveling development area and rural area or other place the cost of underground network is expensive.
Basic Information
Code Name
ABC
Rated Voltage (Uo/U)
0.6/1KV
Temperature Range
-15ºC-90ºC
ABC cable is suitable for transmitting line and distributing line of rated voltage 0.6/1KV and others.It is widely used at tall buildings,traveling development area and rural area or other place the cost of underground network is expensive.
Basic Information
Code Name
ABC
Rated Voltage (Uo/U)
0.6/1KV
Temperature Range
-15ºC-90ºC
—————————————————————————————————————————–
CONSTRUCTION
Conductor: Copper or Aluminium
Insulation: XLPE
Normally,ABC Cable(ABC Bundled Cable-Aerial Cable) do not use copper,because Aluminium Cost is high,most of our customers use aluminium.
—————————————————————————————————————————–
CABLE STANDARDS
Chinese National Standards, IEC,SANS 1418-1, SANS1418-2, ASTMB230, ASTMB231,ASTM B398,ASTM B399, NF C33-209 and etc. upon request.
—————————————————————————————————————————–
Aerial Bundle Conductor-ABC(South Africa Standard Sizes)-SANS 1418-1
Table 01 Aerial Bundled Cable-ABC-AS NZS 3506.1
1+1 Structure | ||||||||||
Phase Conductor | Neutral Conductor | Completed Cable | ||||||||
Section | Insulation Thickness | Minimum number of wires | Max. dc resistance at 20°C | Section | Insulation Thickness | Minimum number of wires | Max. dc resistance at 20°C | Minimum breaking load | Approx. Overall Diameter | Approx. Weight Of Cable |
mm2 | mm | No. | ohm/km | mm2 | mm | No. | ohm/km | KN | mm | Kg/km |
1×16 | 1.3 | 6 | 1.91 | 1×16 | 1.3 | 6 | 1.91 | 4.4 | 15.0 | 140 |
1×25 | 1.3 | 6 | 1.20 | 1×25 | 1.3 | 6 | 1.20 | 7.0 | 17.6 | 210 |
1×35 | 1.5 | 6 | 0.868 | 1×35 | 1.5 | 6 | 0.868 | 9.8 | 19.6 | 270 |
1×50 | 1.5 | 6 | 0.641 | 1×50 | 1.5 | 6 | 0.641 | 14.0 | 22.8 | 370 |
1×95 | 1.7 | 15 | 0.320 | 1×95 | 1.7 | 15 | 0.320 | 26.6 | 30.6 | 680 |
2+1 Structure | ||||||||||
Phase Conductor | Neutral Conductor | Completed Cable | ||||||||
Section | Insulation Thickness | Minimum number of wires | Max. dc resistance at 20°C | Section | Insulation Thickness | Minimum number of wires | Max. dc resistance at 20°C | Minimum breaking load | Approx. Overall Diameter | Approx. Weight Of Cable |
mm2 | mm | No. | ohm/km | mm2 | mm | No. | ohm/km | KN | mm | Kg/km |
2×25 | 1.3 | 6 | 1.20 | 1×25 | 1.3 | 6 | 1.20 | 10.5 | 19.0 | 310 |
2×35 | 1.3 | 6 | 0.868 | 1×35 | 1.3 | 6 | 0.868 | 14.7 | 21.1 | 410 |
2×50 | 1.5 | 6 | 0.641 | 1×50 | 1.5 | 6 | 0.641 | 21.0 | 24.6 | 550 |
3+1 Structure | ||||||||||
Phase Conductor | Neutral Conductor | Completed Cable | ||||||||
Section | Insulation Thickness | Minimum number of wires | Max. dc resistance at 20°C | Section | Insulation Thickness | Minimum number of wires | Max. dc resistance at 20°C | Minimum breaking load | Approx. Overall Diameter | Approx. Weight Of Cable |
3×16 | 1.3 | 6 | 1.91 | 1×16 | 1.3 | 6 | 1.91 | 8.8 | 18.1 | 290 |
3×25 | 1.3 | 6 | 1.20 | 1×25 | 1.3 | 6 | 1.20 | 14.0 | 21.2 | 410 |
3×35 | 1.3 | 6 | 0.868 | 1×35 | 1.3 | 6 | 0.868 | 19.6 | 23.7 | 550 |
3×50 | 1.5 | 6 | 0.641 | 1×50 | 1.5 | 6 | 0.641 | 28.0 | 27.5 | 740 |
3×70 | 1.5 | 12 | 0.443 | 1×70 | 1.5 | 12 | 0.443 | 39.2 | 31.9 | 1000 |
3×95 | 1.7 | 15 | 0.320 | 1×95 | 1.7 | 15 | 0.320 | 53.2 | 36.9 | 1370 |
3×120 | 1.7 | 15 | 0.253 | 1×120 | 1.7 | 15 | 0.253 | 67.2 | 40.6 | 1690 |
3×150 | 1.7 | 15 | 0.206 | 1×150 | 1.7 | 15 | 0.206 | 84.0 | 43.9 | 2020 |
ABC Aerial overhead cable with ACSR messenger Core
Nominal csetion area(sqmm) | Conductor structure | Insulation material | Insulation Thickness(mm) | Approx. Overall Diameter(mm) | Approx. weight (kg/km) |
Packing meters per drum | ||
Phase (Compacted AL) |
Neutral (bare ACSR) |
|||||||
(No./mm) | Aluminum (No./mm) |
Steel (No./mm) |
||||||
1×16+16 | 7/1.72 | 6/1.72 | 1/1.72 | XLPE | 1.2 | 12.5 | 121.9 | 250-4000m |
1×25+25 | 7/2.15 | 6/2.15 | 1/2.15 | 1.2 | 14.9 | 182.2 | 250-4000 | |
1×35+35 | 7/2.54 | 6/2.54 | 1/2.54 | 1.4 | 17.5 | 254.7 | 250-3500m | |
1×70+70 | 19/2.15 | 12/2.15 | 7/2.15 | 1.4 | 23.6 | 382.2 | 250-3000m | |
1×95+95 | 19/2.54 | 12/2.54 | 7/2.54 | 1.6 | 27.6 | 528.2 | 250-3000m | |
2×16+16 | 7/1.72 | 6/1.72 | 1/1.72 | 1.2 | 14.2 | 187.6 | 250-4000m | |
2×25+25 | 7/2.15 | 6/2.15 | 1/2.15 | 1.2 | 16.7 | 273.8 | 250-3500m | |
2×35+35 | 7/2.54 | 6/2.54 | 1/2.54 | 1.4 | 19.7 | 386.9 | 250-3500m | |
2×70+70 | 19/2.15 | 12/2.15 | 7/2.15 | 1.4 | 26.1 | 617.2 | 250-3000m | |
2×95+95 | 19/2.54 | 12/2.54 | 7/2.54 | 1.6 | 30.5 | 850.9 | 250-3500m | |
3×70+70 | 19/2.15 | 12/2.15 | 7/2.15 | 1.4 | 29.7 | 1024.3 | 250-3000m | |
3×95+95 | 19/2.54 | 12/2.54 | 7/2.54 | 1.6 | 34.6 | 1413.7 | 250-3000m |