Aerial Bundle Cable 70mm ABC Cable for Overhead Power Lines
More product about 95mm ABC CableProduct Description
We can supply this conductor according to different recognized standards, such as IEC Standard, ANSI/ICEA , NFC, NBR, ITP ,customer special specification also can be satisfied.
Application of ASTM BS Standard 0.6/1kv pvc/xlpe/pe insulated Duplex aerial bundle cable for ABC cable Conllie, duplex cable, service drop, overhead cable.
The basic construction is as following:
A, 2, 3, 4 power cores consisting of strandard aluminium conductor, insulated with XLPE or PVC, PE.
B, One sheath lighting aluminium conductor with XLPE insulation(optional)
C, One messenger Al-alloy (bare or covered)
It meets or exceeds the following specification:
A, Aluminium wire, 1350-H19 for electrical purposes.
B, Aluminium conductor, concentric-lay-stranded.
C, Aluminium conductor, concentric-lay-stranded, coated steel reinforgorced(ACSR, AAC, AAAC)
D, Concentric-lay stranded 6201-T81 conductors.
E, Compressed Round Stranded Aluminium consuctors using single input wire.
Specifications:
Conductor: Aluminum
Insulation: PVC, XLPE, PE
Application: Overhead line
Core: 2.3, 4 core( Duplex, triplex, quoduplex)
Code word |
AWG or kcmilc | Bare Neutral Messenger | Phase Conductor |
Weight |
Allowable Ampacities(A) |
|||||||
ACSR | Rated strength Ibs. |
AAC | Insul Thick. mm |
XLPE | PE | |||||||
Number | Dia mm | Number | Dia mm | Number | Dia mm | |||||||
Setter | 1*6AWG+1*6AWG | 1 | 1.68 | 6 | 1.68 | 1190 | 1 | 4.11 | 1.14 | 111 | 85 | 70 |
Bull | 1*1/0AWG+1*1/0AWG | 1 | 3.37 | 6 | 3.37 | 4380 | 19 | 1.89 | 1.52 | 427 | 205 | 160 |
Shepherd | 1*6AWG+1*6AWG | 1 | 1.68 | 6 | 1.68 | 1190 | 7 | 1.56 | 1.14 | 113 | 85 | 70 |
Eskimo | 1*4AWG+1*4AWG | 1 | 2.12 | 6 | 2.12 | 1860 | 1 | 5.19 | 1.14 | 171 | 115 | 90 |
Terrier | 1*4AWG+1*4AWG | 1 | 2.12 | 6 | 2.12 | 1860 | 7 | 1.96 | 1.14 | 173 | 115 | 90 |
Chow | 1*2AWG+1*2AWG | 1 | 2.67 | 6 | 2.67 | 2850 | 7 | 2.47 | 1.14 | 266 | 150 | 120 |
Aerial Bundle Conductor-ABC(South Africa Standard Sizes)-SANS 1418-1
Type of conductor or core | Norminal cross-sectional area mm2 | Nubmer of wires Min. |
Diameter of conductormm | Resistanceat 20ºC Ω/km Max. | Breaking force(N) | Thickness of insulation (mm) | Outer diameter of core(mm) | |||
Min. | Max. | Min. | Average | Min. | Min. | Max. | ||||
Phase or auxiliary or non-strain-bearing netural(aluminium) | +16 | 6 | 4.6 | 5.1 | 1.91 | 2070 | 1.2 | 0.98 | 7.0 | 7.8 |
25 | 6 | 5.8 | 6.3 | 1.2 | 3300 | 1.4 | 1.16 | 8.6 | 9.4 | |
35 | 6 | 6.8 | 7.3 | 0.868 | 4500 | 1.6 | 1.34 | 10.0 | 10.9 | |
50 | 6 | 7.9 | 8.4 | 0.641 | 6200 | 1.6 | 1.34 | 11.1 | 12.0 | |
70 | 12 | 9.7 | 10.2 | 0.443 | 8900 | 1.8 | 1.52 | 13.3 | 14.2 | |
95 | 15 | 11.0 | 12.0 | 0.320 | 12300 | 1.8 | 1.52 | 14.6 | 16.0 | |
120 | 15 | 12.5 | 13.5 | 0.253 | 15600 | 1.8 | 1.52 | 16.3 | 17.5 | |
150 | 15 | 13.9 | 15.0 | 0.206 | 19200 | 1.8 | 1.52 | 17.1 | 18.6 | |
Service connection(aluminium) | 16 | 6 | 4.6 | 5.2 | 1.91 | 2070 | 1.2 | 0.98 | 7.0 | 8.0 |
25 | 6 | 5.6 | 6.5 | 1.2 | 3300 | 1.4 | 1.16 | 8.6 | 9.6 | |
Service connection(copper) | 10 | 6 | – | 4.2 | 1.83 | 3600 | 1.2 | 0.98 | 6.2 | 7.0 |
16 | 6 | – | 5.3 | 1.15 | 5760 | 1.2 | 0.98 | 7.2 | 8.0 | |
25 | 6 | – | 6.6 | 0.727 | 8750 | 1.4 | 1.16 | 8.6 | 9.6 | |
Number and nominal diameter of wires mm |
||||||||||
Supporting core(aluminium alloy) |
54.6 | 7×3.15 | 9.2 | 9.6 | 0.630 | 16600 | 1.6 | 1.34 | 12.3 | 13.0 |
70 | 7×3.50 | 10.0 | 10.4 | 0.500 | 20100 | 1.6 | 1.34 | 12.9 | 13.6 | |
+Auxiliary conductors or cores only |
When a supporting core is specified in a tender invitation,the combinations listed in Table 02 below:
1 | 2 |
Nominal cross sectional area of supporting conductor mm2 | Nominal cross-sectional areas of phase conductors mm2 |
54.6 | 25,35,50,70,95 |
70 | 70,95,120 |
95 | 95,120,150 |
Aerial Bundle Conductor-ABC(South Africa Custimized Size Specification)
Type of conductor or core | Norminal cross-sectional area mm2 | Nubmer of wires | Diameter of conductormm | Resistanceat 20ºC Ω/km Max. | Breaking force(N) | Thickness of insulation (mm) | Outer diameter of core(mm) | |||
Min. | Max. | Min. | Average | Min. | Min. | Max. | ||||
Phase or auxiliary or non-strain-bearing netural(aluminium) | 16 | 7/1.65 | 4.6 | 5.1 | 1.91 | 2070 | 1.2 | 0.98 | 7.0 | 7.8 |
25 | 7/2.15 | 5.8 | 6.3 | 1.2 | 3300 | 1.4 | 1.16 | 8.6 | 9.4 | |
35 | 7/2.55 | 6.8 | 7.3 | 0.868 | 4500 | 1.6 | 1.34 | 10.0 | 10.9 | |
50 | 7/2.99 | 7.9 | 8.4 | 0.641 | 6200 | 1.6 | 1.34 | 11.1 | 12.0 | |
70 | 14/2.59 | 9.7 | 10.2 | 0.443 | 8900 | 1.8 | 1.52 | 13.3 | 14.2 | |
95 | 19/2.59 | 11.0 | 12.0 | 0.320 | 12300 | 1.8 | 1.52 | 14.6 | 16.0 | |
120 | 19/2.99 | 12.5 | 13.5 | 0.253 | 15600 | 1.8 | 1.52 | 16.3 | 17.5 | |
150 | 30/2.59 | 13.9 | 15.0 | 0.206 | 19200 | 1.8 | 1.52 | 17.1 | 18.6 | |
Service connection(aluminium) | 16 | 7/1.65 | 4.6 | 5.2 | 1.91 | 2070 | 1.2 | 0.98 | 7.0 | 8.0 |
25 | 7/2.15 | 5.6 | 6.5 | 1.2 | 3300 | 1.4 | 1.16 | 8.6 | 9.6 | |
Service connection(copper) | 10 | 7/1.35 | – | 4.2 | 1.83 | 3600 | 1.2 | 0.98 | 6.2 | 7.0 |
16 | 7/1.69 | – | 5.3 | 1.15 | 5760 | 1.2 | 0.98 | 7.2 | 8.0 | |
25 | 7/2.19 | – | 6.6 | 0.727 | 8750 | 1.4 | 1.16 | 8.6 | 9.6 | |
Supporting core(aluminium alloy) | 16 | 7/1.71 | 5.1 | 5.2 | 2.053 | 5070 | 1.4 | 1.16 | 7.9 | 8.0 |
25 | 7/2.15 | 6.4 | 6.5 | 1.314 | 8000 | 1.4 | 1.16 | 9.2 | 9.3 | |
35 | 7/2.48 | 6.6 | 7.5 | 0.986 | 10300 | 1.6 | 1.34 | 10.7 | 10.8 | |
50 | 7/2.89 | 7.7 | 8.4 | 0.720 | 14200 | 1.6 | 1.34 | 11.9 | 12.0 | |
54.6 | 7/3.15 | 9.2 | 9.6 | 0.630 | 16600 | 1.6 | 1.34 | 12.3 | 13.0 | |
70 | 7/3.50 | 10.0 | 10.4 | 0.500 | 20100 | 1.6 | 1.34 | 12.9 | 13.6 |