Single Core Cable for Building Wiring & Electric Switches

Single Core Cable for Building Wiring & Electric Switches

Single Core Cable for Building Wiring & Electric Switches

6mm2, master cores

Insulated

Solid or Stranded

Heating

Copper

PVC

PVC

Round Wire

Refractory

ISO9001, CE, CCC, RoHS

Jytop

Copper Core

3.4kv

BS, IEC

Flexible

JYTOP

100m Coils

1~1000mm2

Zhengzhou, China

8544492100

Product Description

                                   Single Core Cable for Building Wiring & Electric Switches
ELECTRICAL WIRE PVC insulated electric wire building wire.

SINGLE CORE CABLE
Single core cables are used in buildings for fixed wiring & lighting, electric switches, distribution boards, internal wiring in apparatus, for earthing purpose, etc. Voltage range includes 450/750 V. These cables are manufactured to BS & IEC standards.

Construction
Annealed Plain Copper Conductor , PVC or Heat Resistant PVC Insulation
Applicable Standards:BS EN 50525231 (previously BS 6004) , IEC 602273
Operating Temperature: 70°C for general purpose cables, 90°C for heat resistant cables Properties
Flame retardant to IEC 603321

Application
In dry rooms, laying in conduit on or under plaster and on insulating support above plaster.
Type  H07V-R, H07V-K, H07V-U, H07V2-R, H07V2-K, H07V2-U Rated Voltage 450/750 V
Product Range :1.5 to 1000 mm2
 
 
FLEXIBLE CABLES
Flexible cables are used in auxiliary circuits & euipments, power supply, etc. Voltage range includes 300/500V. These cables are manufactured to BS & IEC standards.

Construction
Annealed Plain Copper Conductor (Class 5)
PVC or Heat Resistant PVC Insulation
PVC or Heat Resistant PVC Sheath
Applicable Standards:  BS EN 50525-2-11 (previously BS 6500), IEC 60227-5
Operating Temperature: 70°C for general purpose cables, 90°C for heat resistant cables
Properties Flame retardant to IEC 60332-1

Application
For household appliances under medium mechanical stress in damp & wet conditions.
Type H05VVF, H05V2V2F Rated Voltage 300/500 V
Product Range
2 core – 0.5 to 10 mm2
3 core – 0.5 to 10 mm2
4 core – 0.5 to 10 mm2
5 core – 0.5 to 10 mm2
 

Size of conductor Nominal thickness of insulation
 
 
mm
Mean overall
diameter
 Upper limit
 mm
Approx. net   weight per km
(kg)
Nominal
cross-sectional area mm2
(one core cable)
Number
and    diameter      of wires
no./mm
1.0 1/1.13 0.6  2.8   14
1.5 1/1.38 0.7  3.3   20
1.5 7/0.50 0.7  3.4   20
2.5 1/1.78 0.8  3.9   33
2.5 7/0.67 0.8  4.2   34
4 1/2.25 0.8  4.4   51
4 7/0.85 0.8  4.8   51
6 1/2.76 0.8  4.9   67
6 7/1.04 0.8  5.4   71
10 1/3.57 1.0  6.4  110
10 7/1.35 1.0  6.8  120
16 1/4.50 1.0  7.3  170
16 7/1.70 1.0  8.0  180
25 7/2.14 1.2  9.8  285
35 19/1.53 1.2 11.0  380
50 19/1.78 1.4 13.0  510
70 19/2.14 1.4 15.0  715
95 19/2.52 1.6 17.0  990
120 37/2.03 1.6 19.0 1230
150 37/2.25 1.8 21.0 1510
185 37/2.52 2.0 23.5 1900
240 61/2.25 2.2 26.5 2490
300 61/2.52 2.4 29.5 3050
400 61/2.85 2.6 33.5 3900
500 61/3.20 2.8 37.0 4880