Copper XLPE Copper Wire Neutral 6mm 10mm 16mm Airdac Cable Concentric Cable
Quick Details
Copper XLPE Copper Wire Neutral 6mm 10mm 16mm Airdac Cable Concentric Cable
Airdac Cable
Yifang Cable
10mm2 Cne Airdac Cable
ISO, CCC, CE
Bare Copper Wire
Round Wire
PVC
XLPE
AC Cable
0.6/1kv
Construction, Overhead, Underground
Black
Sans 1507
China
LLDPE
Yifang
Drum
6, 10, 16mm2
China
8544492100
Product Details
Copper XLPE Copper Wire Neutral 6mm 10mm 16mm Airdac Cable Concentric Cable
Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017
Conductor: Hard Drawn Copper Conductor – Class 2
Insulation: LV-XLPE
Phase Color Code(SNE): Red, Black & Bare Copper
Phase Color Code (CNE): Red & Bare Copper
Application: Used for house connections , with or without coms wire.
Technical Data
4mm², AIRDAC II CNE Cable
Electrical Properties Cable size: 4mm² Phase Conductor Resistance (Ohm/km) DC @ 20 °C: 4,80 Phase Core Impedance (Z) (Ohm/km): 5,88 Current Rating (A)*: 30 Symmetrical Short Circuit Rating for 1s in kA: 0,572 * Note: – In air, with 30 °C ambient with maximum conductor temperature 90 °C Mechanical Properties Cable size: 4mm² Phase Conductor (No.xOD): 7×0.92mm Nominal Insulation Thickness: 1.0mm Earth size: 4mm² Earth Conductor (No.xOD): 8×0.85mm Nominal Sheath Thickness: 1.4mm Approximate Cable OD: 9.0mm Approximate Cable Mass: 121 kg/km Installation Data (SAG* mm): Span 10(mm) :40 Span 20(mm) :165 Span 30(mm) :370 Span 40(mm) :650 Span 50(mm) :1020 Based on UTS** :1480 MWT*** :370 |
10mm², AIRDAC II CNE Cable
Electrical Properties Cable size: 10mm² Phase Conductor Resistance (Ohm/km) DC @ 20 °C: 1,90 Phase Core Impedance (Z) (Ohm/km): 2,34 Current Rating (A)*: 50 Symmetrical Short Circuit Rating for 1s in kA: 1,431 * Note: – In air, with 30 °C ambient with maximum conductor temperature 90 °C Mechanical Properties Cable size: 10mm² Phase Conductor (No.xOD): 7×1.45mm Nominal Insulation Thickness: 1.0mm Earth size: 10mm² Earth Conductor (No.xOD): 18×0.85mm Nominal Sheath Thickness: 1.4mm Approximate Cable OD: 11.0mm Approximate Cable Mass: 249 kg/km Installation Data (SAG* mm): Span 10(mm) :35 Span 20(mm) :140 Span 30(mm) :310 Span 40(mm) :550 Span 50(mm) :870 Based on UTS** :3600 MWT*** :900 |
Separate Neutral and Earth (SNE) Airdac 600/1000V
Cable Size |
Neutral Size |
Earth Size |
Pilot Cores |
Overall Diameter |
Cable Mass |
Current Rating |
Phase Core Impedance |
mm² | mm² | mm² | mm | mm | kg/m | amps | ohms/km |
10 | 10 | 7.5 | 2 x 0.5 | 12.8 | 0.32 | 90 | 2.34 |
16 | 16 | 10 | 2 x 0.5 | 14.5 | 0.485 | 125 | 1.47 |
Combined Neutral and Earth (CNE) Airdac 600/1000V
Cable Size |
Earth Size |
Overall Diameter |
Cable Mass |
Current Rating |
Phase Core Impedance |
mm² | mm² | mm | kg/m | amps | ohms/km |
4 | 4 | 8.7 | 0.121 | 47 | 5.88 |
10 | 10 | 11 | 0.249 | 86 | 2.34 |