6/10kv N2xs2y Copper Conductor XLPE Insulated Underground Power Cable
Product Description
Standard:
Power cables with extruded insulation and their accessories for rated voltage 1kV(Um=1.2kv) to 35KV (Um=40.5KV)
Application:
The XLPE Insulated Medium Voltage Underground Power Cable Wire is used for power transmission system with rated voltage from 6-35kV.
Features of XLPE Insulated Medium Voltage Underground Power Cable Wire application
*AC Voltage (U0/U)kV, recommend use 8.7/10, 8.7/15,26/35
*The Max working temp; when short circuit (the max resistance time not more than 5 sec.), the conductor temp. not more than 250 degree.
*The min. working temp. is -15 degree.
*The laying temp. not less 0 degree.
*The allowable bending radius is 15-20D.
Rated Voltage, No. of Core and Range of Sectional Area
Rated voltage (kv) Sectional area (mm2) No. of core |
1st class | 0.6/1 | 1.8/3 | 3.6/6 | 6/10 | 8.7/15 | 12/20 | 18/30 | 21/35 |
2nd class | 1/1 | 3/3 | 6/6 | 8.7/10 | 12/15 | 18/20 | – | 26/35 | |
1 Core | 1.5-800 | 25-800 | 25-1200 | 25-1200 | 35-1200 | 50-1200 | 50-1200 | 50-1200 | |
2 Core | 1.5-185 | 25-185 | |||||||
3 Core | 1.5-400 | 25-400 | 25-400 | 25-400 | 35-400 | 50-400 | 50-400 | 50-400 | |
4 Core | 2.5-400 | 25-400 | |||||||
5 Core | 2.5-400 | 25-400 |
Main Technical Quota
DC resistance: conductor resistance of finished cable at 20ºC per kilometer is not more than the following values.
Nominal section area (mm2) | 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800 |
Copper core | 12.1 7.41 4.61 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283 0.0221 |
Aluminum core | 18.1 12.1 7.41 4.61 3.08 1.91 1.20 0.868 0.641 0.443 0.320 0.253 0.206 0.164 0.125 0.100 0.778 0.0605 0.0469 0.0367 |
Voltage Test and Partial Discharge Test
Rate voltage Uo (kv) Item |
0.6/1 | 1.8/3 | 3.6/6 | 6/6 6/10 | 8.7/10 8.7/15 | 12/20 | 18/20 18/30 | 21/35 | 26/35 | |
Voltage | Test voltage | 3.5 | 6.5 | 12.5 | 21 | 30.5 | 42 | 63 | 73.5 | 91 |
Test time | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | |
Partial discharge test | Test voltage | – | – | 6.2 | 10.4 | 15.1 | 20.8 | 31.1 | 36.3 | 45 |
Discharge capacity | – | – | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
Packing
Packing in wooden drums,steel wooden drums or as customer’s requirement.
Customer Visit
We have a professional sales team with each of them has engaged in this job for 3-10 years, so that we can provide the comprehensive and professional technology for you. With the perfect quality and after sales service, till now we have exported to more than 80 countries, welcome to visit us and establish win-win establish relationship!
Production process:
Certificate
As first rank of the cable supplier in China, we have obtained CCC, ISO9001, ISO14001, OHSAS certificates, passed the SGS and BV test, and our brand "RMJT" be given China famous brand.
About us:
People’s Cable Group Co., Ltd. was founded in 2007, located in Zhengzhou Gongyi economic development zone. Our company has 2 factories (Zhitian factory and Zhulin factory), occupies total area of more than 300,000 square meters, with building area 230,000 square meters.
- Next: Flexible Yjlv 4 Cores Electrical Power Cable
- Previous: Medium Voltage XLPE Insulation Swa Armored Copper Tape Screen Copper Conductor Power Cable