25mm2 PE Insulated ABC Cable (25mm2+25 mm2)

Product Description
25mm2 PE Insulated ABC Cable (25mm2+25 mm2)
Applications of abc cable 25mm2
Primarily used for 120 volt overhead service applications such as street lighting, outdoor lighting, and temporary service
for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed
75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.
Specification of abc cable 25mm2
service drop cable meets or exceeds the following ASTM specifications:
· B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
· B-231 Aluminum Conductors, Concentric-Lay-Stranded.
· B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
· B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
· B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire
Construction
Conductors are concentrically stranded, compressed 1350 H-19 aluminum. Insulated with either polyethylene or
crosslinked polyethylene (XLP). Neutral messengers are concentrically stranded 6201, AAC, or ACSR.
Teachnical Data
|
Spec mm2 |
Conductor structure |
Insulation Material |
Insulation Thickness (mm) |
Approx overall diameter (mm) |
Approx weight (kg/km) |
|
|
Phase |
Neutral (alloy) |
|||||
|
No./mm |
No./mm |
|||||
|
1*16+1*16 |
7/1.72 |
7/1.72 |
XLPE (HDPE) |
1.2 |
12.5 |
110.1 |
|
1*25+1*25 |
7/2.15 |
7/2.15 |
1.2 |
14.9 |
163.9 |
|
|
1*35+1*35 |
7/2.54 |
7/2.54 |
1.4 |
17.5 |
229.0 |
|
|
1*50+1*50 |
7/2.92 |
7/2.92 |
1.4 |
20.1 |
300.0 |
|
|
1*70+1*70 |
19/2.15 |
19/2.15 |
1.4 |
23.6 |
423.2 |
|
|
1*95+1*95 |
19/2.54 |
19/2.54 |
1.6 |
27.6 |
585.4 |
|
|
2*16+1*16 |
7/1.72 |
7/1.72 |
1.2 |
14.2 |
175.8 |
|
|
2*25+1*25 |
7/2.15 |
7/2.15 |
1.2 |
16.7 |
258.4 |
|
|
2*35+1*35 |
7/2.54 |
7/2.54 |
1.4 |
19.7 |
361.2 |
|
|
2*50+1*50 |
7/2.92 |
7/2.92 |
1.4 |
22.5 |
472.1 |
|
|
2*70+1*70 |
19/2.15 |
19/2.15 |
1.4 |
26.1 |
658.3 |
|
|
2*95+1*95 |
19/2.54 |
19/2.54 |
1.6 |
30.5 |
908.2 |
|
|
3*16+1*16 |
7/1.72 |
7/1.72 |
1.2 |
16.3 |
241.5 |
|
|
3*25+1*25 |
7/2.15 |
7/2.15 |
1.2 |
19.1 |
353.6 |
|
|
3*35+1*35 |
7/2.54 |
7/2.54 |
1.4 |
22.5 |
493.5 |
|
|
3*50+1*50 |
7/2.92 |
7/2.92 |
1.4 |
25.7 |
644.1 |
|
|
3*70+1*70 |
19/2.15 |
19/2.15 |
1.4 |
29.7 |
895.2 |
|
|
3*95+1*95 |
19/2.54 |
19/2.54 |
1.6 |
34.6 |
1233. |
|
- Next: 3*35+35mm2 Aluminum Cable ABC Overhead Insulated Cable
- Previous: 0.6/1kv XLPE or PE Insulated ABC Conductor 3X95+50mm2
Contact us
Similar Or Related
-
Aster Cable 366mm2 37 Strands AAAC Bare Conductor for 90kV HV Substation
-
AAAC Bare Conductor 100mm2 7/4.26mm for Uganda 33kV Distribution Line
-
AAAC Bare Conductor 50mm2 7/3.02mm for Uganda 11kV Distribution Line
-
Aerial Bundled Conductor 70mm2 Hard drawn Aluminum ABC Cable for 400V Distribution Line
-
50mm2;AAAC PVC Covered Hazel Conductor BS 3242 for 11kV Distribution Line