IEC 60502-2 Three Core XLPE Insualted Armour 6.35/11kv Copper Cable
IEC 60502-2 Three Core XLPE Insualted Armour 6.35/11kv Copper Cable
YJV32
Jinyuan
ISO9001, CCC
Flame Retardant
Round Wire
XLPE
PVC
Copper
Underground
Stranded
Insulated
Jinyuan
Iron Wooden
25mm2-800mm2
China
Product Description
Wholesale Power Electric Cable With XLPE Insulated
Technical Parameters of our Power Cable
1). Standard: IEC60502; GB/T12706;IEC 60840;IEC62067;GB/T 11017;GB/Z 18890
2). Detailed description or construction:
* Conductor: compacted or uncompacted copper or aluminium
* Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)
* Filler: Polypropylene filament with lapped binding tape
* Binder: Binding tape
* Inner sheath: Polyvinyl chloride (PVC)
* Armour: Galvanized steel wire armored (SWA) or steel tape armored (STA)
*Sheath: Polyvinyl chloride (PVC)
3). The rated voltages U0/U(Um) of the cables considered in this standard are as follows:
U0/U(Um) =0.6/1(1.2)-3.6/6(7.2)-6/10(12)-6.35/11(12)-8.7/15(17.5)-12/20(24)-12.7/22(24)-18/30(36)-19/33(36)-26/35(40.5)KV
4). Voltage:
0.6/1kV, 1.8/3kV, 3.6/6kV, 6/10kV,6.35/11kV, 8.7/15kV, 12/20kV,12.7/22kV, 18/30kV,19/33kV,26/35kV
In the voltage designation of cables U0/U(Um):
* U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
* U is the rated power frequency voltage between conductors for which the cable is designed;
* Um is the maximum value of the "highest system voltage" for which the equipment maybe used.
5). Application:
For laying indoors, in tunnel or cable trench with large difference of level able to bear external mechanical forces.
6). Marking: According to the customers’ requirements
7). Nominal cross-sectional areas:
1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2, 500mm2, 630mm2, 800mm2
Technical Parameters of our Power Cable
1). Standard: IEC60502; GB/T12706;IEC 60840;IEC62067;GB/T 11017;GB/Z 18890
2). Detailed description or construction:
* Conductor: compacted or uncompacted copper or aluminium
* Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)
* Filler: Polypropylene filament with lapped binding tape
* Binder: Binding tape
* Inner sheath: Polyvinyl chloride (PVC)
* Armour: Galvanized steel wire armored (SWA) or steel tape armored (STA)
*Sheath: Polyvinyl chloride (PVC)
3). The rated voltages U0/U(Um) of the cables considered in this standard are as follows:
U0/U(Um) =0.6/1(1.2)-3.6/6(7.2)-6/10(12)-6.35/11(12)-8.7/15(17.5)-12/20(24)-12.7/22(24)-18/30(36)-19/33(36)-26/35(40.5)KV
4). Voltage:
0.6/1kV, 1.8/3kV, 3.6/6kV, 6/10kV,6.35/11kV, 8.7/15kV, 12/20kV,12.7/22kV, 18/30kV,19/33kV,26/35kV
In the voltage designation of cables U0/U(Um):
* U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
* U is the rated power frequency voltage between conductors for which the cable is designed;
* Um is the maximum value of the "highest system voltage" for which the equipment maybe used.
5). Application:
For laying indoors, in tunnel or cable trench with large difference of level able to bear external mechanical forces.
6). Marking: According to the customers’ requirements
7). Nominal cross-sectional areas:
1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2, 500mm2, 630mm2, 800mm2
Type | Designation | Applications |
VV YJV VLV YJLV |
Copper conductor, PVC ,XLPE insulated, PVC sheathed power cable Aluminium conductor, PVC ,XLPE insulated, PVC sheathed power cable |
For laying indoors, in tunnel or cable trench, unable to bear external mechanical forces. Single core cable is not permissible to lay in magnetic duct. |
VY YJY VLY YJLY |
Copper conductor, PVC,XLPE insulated, PE sheathed power cable Aluminium conductor, PVC ,XLPE insulated, PE sheathed power cable |
|
VV22 YJV22 VLV22 YJLV22 |
Copper conductor, PVC ,XLPE insulated, steel tape armoured, PVC sheathed power cable Aluminium conductor, PVC ,XLPE insulated, steel tape armoured, PVC sheathed power cable |
For laying indoors, in tunnel, in cable trench or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force. |
VV23 YJV23 VLV23 YJLV23 |
Copper conductor, PVC ,XLPE insulated, steel tape armoured, PE sheathed power cable Aluminium conductor, PVC ,XLPE insulated, steel tape armoured, PE sheathed power cable |
|
VV32 YJV32 VLV32 YJLV32 |
Copper conductor, PVC ,XLPE insulated, steel wire armoured, PVC sheathed power cable Aluminium conductor, PVC ,XLPE insulated, steel wire armoured, PVC sheathed power cable |
For laying indoors, in tunnel, in cable trench or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force. |
VV33 YJV33 VLV33 YJLV33 |
Copper conductor, PVC ,XLPE insulated, steel wire armoured, PE sheathed power cable Aluminium conductor, PVC ,XLPE insulated, steel wire armoured, PE sheathed power cable |
|
Note: The armoured single core cables is only used for D.C. system. As for A.C. system, non-magnetic armour material should be applied. |
NOTE:
If you want to know more details about this kind of products, please visit our website(homepage) because we have no ways to show so much information on this platform. Thank you.
Size |
Nominal thickness of XLPE insulation(mm) | Approx. thickness of copper tape screen (mm) | Nominal thickness of steel tape(mm) | Nominal thickness of PVC or PE(mm) | Approx. overall diameter of finished cable(mm) | Max. conductor D.C resistance @ 20ºC(Ω/km) |
3x25mm 2 | 3.4 | 0.10 | 0.5 | 2.3 | 45.7 | 0.727 |
3x35mm 2 | 3.4 | 0.10 | 0.5 | 2.4 | 48.1 | 0.524 |
3x50mm 2 | 3.4 | 010 | 0.5 | 2.5 | 50.9 | 0.387 |
3x70mm 2 | 3.4 | 0.10 | 0.5 | 2.6 | 54.8 | 0.268 |
3x95mm 2 | 3.4 | 0.10 | 0.5 | 2.7 | 58.8 | 0.193 |
3x120mm 2 | 3.4 | 0.10 | 0.5 | 2.9 | 62.4 | 0.153 |
3x150mm 2 | 3.4 | 0.10 | 0.5 | 3.0 | 66.2 | 0.124 |
3x185mm 2 | 3.4 | 0.10 | 0.5 | 3.1 | 70.1 | 0.0991 |
3x240mm 2 | 3.4 | 0.10 | 0.5 | 3.3 | 75.9 | 0.0754 |
3x300mm 2 | 3.4 | 0.10 | 0.5 | 3.4 | 80.7 | 0.0601 |
3x400mm 2 | 3.4 | 0.10 | 0.8 | 3.7 | 89.8 | 0.0470 |
Welcome to our factory , our website:htcable.cn
Mobile:+86 156 0374 9203
- Next: IEC 60502-2 Single Core XLPE Insualted Armour 18/30kv Copper Cable
- Previous: IEC 60502-2 Single Core XLPE Insualted Armour 19/33kv Copper Cable