China Lowest Price 0.6/1kv Al/XLPE ABC Cable (aerial bundle cable) , Power Cable

China Lowest Price 0.6/1kv Al/XLPE ABC Cable (aerial bundle cable) , Power Cable

China Lowest Price 0.6/1kv Al/XLPE ABC Cable (aerial bundle cable) , Power Cable

ABC Cable

Jinyuan

ISO9001, CE, CCC, RoHS

Overhead

Round Wire

XLPE

No

Aluminum

Overhead, Underground

Stranded

Insulated

LV. Mv. Hv

as Per Your Customers ' Request

PVC/PE/XLPE

Jinyuan

All Wooden, Steel Wooden or Steel Package

China

8544492100

Product Description

Application

Used for overhead power transmission and distribution lines of AC rated voltage up to and including 1kV or rated voltage 10kV.

Standard

Rated voltages up to and including 1KV aerial insulated cable implement the standard GB/T 12527, ANSI/ICEA S-76-474, NFC 33029, BS 7870-5, DINVDE0276-626-A1, AS3560-1. Rated voltage 10KV aerial insulated cable implement the standard GB/T 14049.

Application Properties

Rated voltage is up to and including 1KV, 10KV.

The conductor long-term maximum working temperature:PVC and PE insulation should not exceed 70 °C,XLPE insulation should not exceed 90°C.

During short circuit (maximum permanent time is not more than 5 seconds), the maximum temperature of cable conductor : XLPE insulation 250°C, High-density polyethylene insulation 150°C;

When laying the cable, minimum ambient temperature of laying should not be lower than -20°C.

The minimum bending radius:≥20 (D+d)±5%mm, D is the cable overall diameter, d is the conductor diameter.

Product Performance

Conductor DC resistance ( at 20°C ) conform to the stipulation of GB/T 3956-2008.

AC Volage Test:3.5kV,lasting for 5min,without breakdown.

Type and Description

Overhead Insulated Power Cable of rated voltage up to and including 1kV.

Type

Description

Main Application

JKV

Copper conductor PVC insulated overhead cable with rated voltage 1KV.

Overhead fixed installation, Lead household line.

JKLV

Aluminum conductor PVC insulated overhead cable with rated voltage 1KV.

JKLHV

Aluminum alloy conductor PVC insulated overhead cable with rated voltage 1KV.

JKY

Copper conductor PE insulated overhead cable with rated voltage 1KV.

JKLY

Aluminum conductor PE insulated overhead cable with rated voltage 1KV.

JKLHY

Aluminum alloy conductor PE insulated overhead cable with rated voltage 1KV.

JKLGY

ACSR conductor PE insulated overhead cable with rated voltage 1KV.

JKYJ

Copper conductor XLPE insulated overhead cable with rated voltage 1KV.

JKLYJ

Aluminum conductor XLPE insulated overhead cable with rated voltage 1KV.

JKLHYJ

Aluminum alloy conductor XLPE insulated overhead cable with rated voltage 1KV.

JKLGYJ

ACSR conductor PE insulated overhead cable with rated voltage 1KV.

 

Specification

Overhead Insulated Power Cable of Rated Voltages up to and Including 1 kv.

 

Type

Core

Main line core nominal area mm2

JKV,JKLV,JKLHV,JKY,

JKLY,JKLHY,JKLGY,JKYJ,

JKLYJ,JKLHYJ,JKLGYJ

1

10~400

2,4

10~120

JKLV,JKLY,JKLYJ

3+k

10~120

K is the no of neutral core or load bearing line core. According to engineering requirements, to select one to go with the main core.

(A) represents steel stranded neutral core.

(B) represents aluminium alloy stranded neutral core.

 

Triplex Aluminum Service Drop Cable

Code Word Phase conductor Bare Neutral Messenger Weight Per 1000 ft. (lbs.) Allowable Ampacity+
Size (AWG) Stranding Insul. Thick. (mils) Size (AWG) Size (kcmil) Strand- ing Rated Strength (lbs.) XLP POLY XLP POLY
AAAC 6201 ALLOY FULL NEUTRAL MESSENGER
Minex 6 1 45 6 30.58 7 1110 101 101 85 70
Hippa 6 7 45 6 30.58 7 1110 107 107 85 70
Prawn 4 1 45 4 48.69 7 1760 152 152 115 90
Barnacle 4 7 45 4 48.69 7 1760 160 160 115 90
Shrimp 2 7 45 2 77.47 7 2800 243 243 150 120
Gammarus 1/0 7 60 1/0 123.3 7 4460 390 390 205 160
Leda 1/0 9 60 1/0 123.3 7 4460 384 384 205 160
Dunganese 2/0 7 60 2/0 155.4 7 5390 474 474 235 185
Cyclops 2/0 11 60 2/0 155.4 7 5390 474 474 235 185
Flustra 3/0 17 60 3/0 195.7 7 6790 587 587 275 215
Lepas 4/0 18 60 4/0 246.9 7 8560 728 728 315 245
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.++Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201.

 

Code Word Phase conductor Bare Neutral Messenger Weight Per 1000 ft. (lbs.) Allowable Ampacity+
Size (AWG) Stranding Insul. Thick. (mils) Size (AWG) Size (kcmil) Strand- ing Rated Strength (lbs.) XLP POLY XLP POLY
AAAC 6201 ALLOY REDUCED NEUTRAL MESSANGER
Artemia 4 1 45 6 30.58 7 1110 135 135 115 90
Crab 4 7 45 6 30.58 7 1110 143 143 115 90
Solaster 2 7 45 4 48.69 7 1760 216 216 150 120
Sandcrab 1/0 7 60 2 77.47 7 2800 347 347 205 160
Echinus 1/0 9 60 2 77.47 7 2800 341 341 205 160
Crayfish 2/0 7/w 60 mls 2/0 7 2510 485.8 455.3 235 Amps 185 Amps
Sipho 2/0 7/w 60 mls 2/0 7 2510 485.8 455.3 235 Amps 185 Amps
Fulgar 3/0 17 60 1/0 123.3 7 4460 519 519 275 215
Arca 4/0 18 60 2/0 155.4 7 5390 643 643 315 245
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.++Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201.

 
 

Code Word Phase conductor Bare Neutral Messenger Weight Per 1000 ft. (lbs.) Allowable Ampacity+……………
Size (AWG) Stranding Insul. Thick. (mils) Size (AWG) Strand- ing Rated Strength (lbs.) XLP POLY XLP POLY
AAC NEUTRAL-MESSENGER
Haiotis 6 7/w 45 mls 6 7 563 109.1 101.6 85 Amps 70 Amps
Patella 6 7 45 6 7 563 103 103 85 70
Fusus 4 7/w 45 mls 4 7 881 161.8 151.7 115 Amps 90 Amps
Oyster 4 7 45 4 7 881 154 154 115 90
Clam 2 7 45 2 7 1350 233 233 150 120
Murex 1/0 7 60 1/0 7 1990 374 374 205 160
Purpura 1/0 9 60 1/0 7 1990 368 368 205 160
Nassa 2/0 7 60 2/0 7 2510 462 462 235 185
Melita 3/0 17 60 3/0 19 3310 562 562 275 215
Portunus 4/0 18 60 4/0 19 4020 696 696 315 245
Nannynose 336.4 19 80 336.4 19 6146 1118 1118 420 325
* Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+ Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.

 

Code Word Phase conductor Bare Neutral Messenger Weight Per 1000 ft. (lbs.) Allowable Ampacity+
Size (AWG) Stranding Insul. Thick. (mils) Size (AWG) Strand- ing Rated Strength (lbs.) XLP POLY XLP POLY
ASCR NEUTRAL-MESSENGER
Paludina 6 1 45 6 6/1 1190 109 109 85 70
Voluta 6 7 45 6 6/1 1190 114 114 86 70
Whelk 4 1 45 4 6/1 1860 164 115 90
Periwinkle 4 7 45 4 6/1 1860 172 172 115 90
Conch 2 7 60 1/0 6/1 4380 420 420 205 160
Neritina 1/0 7 60 1/0 6/1 4380 420 420 205 160
Cenia 1/0 9 60 1/0 6/1 4380 414 414 205 160
Runcina 2/0 7 60 2/0 6/1 5310 520 520 235 185
Triton 2/0 11 60 2/0 6/1 5310 512 512 235 185
Mursia 3/0 17 60 3/0 6/1 6620 635 635 275 215
Zuzara 4/0 18 60 4/0 6/1 8350 789 789 315 245
Limpet 336.4 19 80 336.4 18/1 8680 1167 1167 420 325
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.

 

Code Word Phase conductor Bare Neutral Messenger Weight Per 1000 ft. (lbs.) Allowable Ampacity+
Size (AWG) Stranding Insul. Thick. (mils) Size (AWG) Strand- ing Rated Strength (lbs.) XLP POLY XLP POLY
ASCR REDUCED NEUTRAL-MESSENGER
Scallop 4 1 45 6 6/1 1190 142 115 90
Strombus 4 7 45 6 6/1 1190 151 151 115 90
Cockle 2 7 45 4 6/1 1190 220 220 150 120
Janthina 1/0 7 60 2 6/1 2853 366 366 205 160
Ranella 1/0 9 60 2 6/1 2853 360 360 205 160
Cavolinia 2/0 7 60 1 6/1 3550 453 453 235 185
Clio 2/0 11 60 1 6/1 3550 444 444 235 185
Sanddollar 3/0 19/w 60 mls 1/0 6/1 4380 565 552 275 Amps 215 Amps
Aega 3/0 17 60 1/0 6/1 4380 549 549 275 215
Cuttlefish 4/0 19/w 60 mls 2/0 6/1 5310 699 684 315 Amps 245 Amps
Cerapus 4/0 18 60 2/0 6/1 5310 681 681 315 245
Cowery 336.4 19 80 mls 336/4 18/1 8680 1209 1167 420 Amps 325 Amps
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.

Tags: , , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.