Overhead Aluminum Aerial Bundle Duplex/Triplex Service Drop Cable

Product Description
(1)Production capacity:500,000km/month
(2)MOQ:1km
(3)Delivery:5~15 official days.
(4)Standards:IEC,ASTM,DIN,BS; or according to customers’ requirements.
ABC CABLE Specification
(1) PHASE CONDUCTORS :
Phase conductors made of aluminium wires are circular stranded, rounded and compacted with smooth circular surface.Our products are avaible 16 mm2 as solid, 25 to 70 mm2 7 wired; from 95 mm2 to onwards as 19 wired confirming TS 11654.
(2) MESSENGER (NEUTRAL) CONDUCTOR :
Bare, round, stranded and compacted aluminium alloy (294 N/mm2).
(3) INSULATION :
Phase conductors of Aerial Bundled Cables are insulated by black coloured PE or XLPE which are weather resistant.
(4) CORE IDENTIFICATION :
Phase conductors two, three and four longitudinal ridges, street lighting conductor without ridges.
(5) USAGE AREA & ADVANTAGES OF ABC SYSTEMS
The usage of Aerial Bundled Cables in low voltage networks provides important saving in installation costs, while it ensures the same reliability and safety, replaces bare conductors in overhead distribution lines and increased very rapidly all around the world.
ABC cable technical parameters
| EC mm 2 |
Conductor structure |
Insulation Material |
Insulation Thickness (mm) |
Approx overall diameter (mm) |
Approx weight (kg/km) |
|
| Phase (compacted Al) |
Neutral (alloy) |
|||||
| No./mm |
No./mm |
|||||
| 1*16+1*16 |
7/1.72 |
7/1.72 |
XLPE (HDPE) |
1.2 |
12.5 |
110.1 |
| 1*25+1*25 |
7/2.15 |
7/2.15 |
1.2 |
14.9 |
163.9 |
|
| 1*35+1*35 |
7/2.54 |
7/2.54 |
1.4 |
17.5 |
229.0 |
|
| 1*50+1*50 |
7/2.92 |
7/2.92 |
1.4 |
20.1 |
300.0 |
|
| 1*70+1*70 |
19/2.15 |
19/2.15 |
1.4 |
23.6 |
423.2 |
|
| 1*95+1*95 |
19/2.54 |
19/2.54 |
1.6 |
27.6 |
585.4 |
|
| 2*16+1*16 |
7/1.72 |
7/1.72 |
1.2 |
14.2 |
175.8 |
|
| 2*25+1*25 |
7/2.15 |
7/2.15 |
1.2 |
16.7 |
258.4 |
|
| 2*35+1*35 |
7/2.54 |
7/2.54 |
1.4 |
19.7 |
361.2 |
|
| 2*50+1*50 |
7/2.92 |
7/2.92 |
1.4 |
22.5 |
472.1 |
|
| 2*70+1*70 |
19/2.15 |
19/2.15 |
1.4 |
26.1 |
658.3 |
|
| 2*95+1*95 |
19/2.54 |
19/2.54 |
1.6 |
30.5 |
908.2 |
|
| 3*16+1*16 |
7/1.72 |
7/1.72 |
1.2 |
16.3 |
241.5 |
|
| 3*25+1*25 |
7/2.15 |
7/2.15 |
1.2 |
19.1 |
353.6 |
|
| 3*35+1*35 |
7/2.54 |
7/2.54 |
1.4 |
22.5 |
493.5 |
|
| 3*50+1*50 |
7/2.92 |
7/2.92 |
1.4 |
25.7 |
644.1 |
|
| 3*70+1*70 |
19/2.15 |
19/2.15 |
1.4 |
29.7 |
895.2 |
|
| 3*95+1*95 |
19/2.54 |
19/2.54 |
1.6 |
34.6 |
1233.5 |
|
- Next: Aluminium Conductor Steel Tape Armoured PVC Sheath Cable
- Previous: U80bl Porcelain Insulator Disk Type
Contact us
Similar Or Related
-
600/1000V AAC Conductor PE Insulated Duplex Service Drop Aerial Cable
-
Duplex Service Drop Aerial Bundled Cable XLPE Insulated ABC Cable
-
Aluminum Conductor Duplex Service Drop PE Insulated ABC Cable
-
Shepherd Core XLPE Insulation Duplex Service Drop Aerial Bounded Cable
-
Aluminium Strand Conductor Duplex Service Drop Insulated Aerial Cable






