(Aerial Bundled Cable) ABC Cable (for duplex, triplex, quadruplex service drop) with Overhead Cable, Twisted Cable
1. Duplex Service Drop-Aluminum Conductor
Construction:
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.
Standards: ASTM B-230, B-231, B-232 and B-399 & ICEA S-76-474
Code Name |
Phase Conductor | Bare Neutral Messenger | Weight Per 1000 ft(lbs) |
Rating(Amps) | ||||||
Size AWG |
Strand | Insulation thickness (mls) |
Size AWG |
*Strand | Breaking strength (lbs) |
XLP | POLY | XLP | POLY | |
AAC | ||||||||||
Pekingese | 6 | solid | 45 | 6 | 7/w | 563 | 63.5 | 61.7 | 70 | 70 |
Collie | 6 | 7/w | 45 | 6 | 7/w | 563 | 66.8 | 63.1 | 70 | 70 |
Dachshund | 4 | solid | 45 | 4 | 7/w | 881 | 95.5 | 93.4 | 90 | 90 |
Spaniel | 4 | 7/w | 45 | 4 | 7/w | 881 | 100.5 | 95.4 | 90 | 90 |
Doberman | 2 | 7/w | 45 | 2 | 7/w | 1,350 | 152.7 | 145.7 | 120 | 120 |
Malemute | 1/0 | 19/w | 60 | 1/0 | 7/w | 1,990 | 242.6 | 234.2 | 160 | 160 |
ACSR NEUTRAL-MESSENGER | ||||||||||
Setter | 6 | solid | 45 | 6 | 6/1 | 1.190 | 75.0 | 73.2 | 70 | 70 |
Shepherd | 6 | 7/w | 45 | 6 | 6/1 | 1.190 | 78.3 | 74.6 | 70 | 70 |
Eskimo | 4 | solid | 45 | 4 | 6/1 | 1.860 | 113.7 | 111.6 | 90 | 90 |
Terrier | 4 | 7/w | 45 | 4 | 6/1 | 1.860 | 118.7 | 113.6 | 90 | 90 |
Chow | 2 | 7/w | 45 | 2 | 6/1 | 2.850 | 181.7 | 174.7 | 120 | 120 |
Bull | 1/0 | 19/w | 60 | 1/0 | 6/1 | 4.380 | 288.7 | 280.3 | 160 | 160 |
6201 ALLOY NEUTRAL-MESSENGER | ||||||||||
Chihuahua | 6 | solid | 45 | 6 | 7/w | 1,110 | 67.6 | 65.8 | 70 | 70 |
Vizsla | 6 | 7/w | 45 | 6 | 7/w | 1,110 | 70.9 | 67.2 | 70 | 70 |
Harrier | 4 | solid | 45 | 4 | 7/w | 1,760 | 102.0 | 99.9 | 90 | 90 |
Whippet | 4 | 7/w | 45 | 4 | 7/w | 1,760 | 107.0 | 101.9 | 90 | 90 |
Schnauzer | 2 | 7/w | 45 | 2 | 7/w | 2,800 | 163.3 | 156.2 | 120 | 120 |
Heeler | 1/0 | 19/w | 60 | 1/0 | 7/w | 4,460 | 259.2 | 250.8 | 160 | 160 |
2. Triplex Service Drop-Aluminum Conductor
Construction:
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.
Standards: ASTM B-230, B-231, B-232 and B-339 & ICEA S-76-474
Code Name |
Phase Conductor | Bare Neutral Messenger | Weight Per 1000 ft(lbs) |
Ampacity (Amps) | |||||||
Size AWG |
Stranding | Insulation thickness (mls) |
Size AWG |
Stranding | Breaking strength (lbs) |
XLP | POLY | XLP | POLY | ||
6201 ALLOY NEUTRAL-MESSENGER | |||||||||||
Minex | 6 | solid | 45 | 6 | 7 | 1,110 | 106.6 | 102.9 | 85 | 70 | |
Hippa | 6 | 7/w | 45 | 6 | 7 | 1,110 | 113.2 | 105.7 | 85 | 70 | |
Prawn | 4 | solid | 45 | 4 | 7 | 1,760 | 158.4 | 154.1 | 115 | 90 | |
Barnacles | 4 | 7/w | 45 | 4 | 7 | 1,760 | 168.3 | 158.2 | 115 | 90 | |
Shrimp | 2 | 7/w | 45 | 2 | 7 | 2,800 | 253.7 | 239.7 | 150 | 120 | |
Gammarus | 1/0 | 7/w | 60 | 1/0 | 7 | 4,460 | 411.7 | 386.0 | 205 | 160 | |
Leda | 1/0 | 19/w | 60 | 1/0 | 7 | 4,460 | 402.7 | 386.0 | 205 | 160 | |
Dungenese | 2/0 | 7/w | 60 | 2/0 | 7 | 5,390 | 506.8 | 476.3 | 235 | 185 | |
Cyclops | 2/0 | 19/w | 60 | 2/0 | 7 | 5,390 | 495.3 | 476.3 | 235 | 185 | |
Flustra | 3/0 | 19/w | 60 | 3/0 | 7 | 6,790 | 611.4 | 589.1 | 275 | 215 | |
Lepas | 4/0 | 19/w | 60 | 4/0 | 7 | 8,560 | 757.1 | 730.5 | 315 | 245 | |
6201 ALLOY REDUCED NEUTRAL-MESSENGER | |||||||||||
Artemia | 4 | solid | 45 | 6 | 7 | 1,110 | 141.4 | 137.1 | 115 | 90 | |
Crab | 4 | 7/w | 45 | 6 | 7 | 1,110 | 151.3 | 141.2 | 115 | 90 | |
Solaster | 2 | 7/w | 45 | 4 | 7 | 1,760 | 226.6 | 212.6 | 150 | 120 | |
Sandcrab | 1/0 | 7/w | 60 | 2 | 7 | 2,800 | 368.8 | 343.1 | 205 | 160 | |
Echinus | 1/0 | 19/w | 60 | 2 | 7 | 2,800 | 358.8 | 343.1 | 205 | 160 | |
Crayfish | 2/0 | 7/w | 60 | 1 | 7 | 3,530 | 452.6 | 422.5 | 235 | 185 | |
Sipho | 2/0 | 19/w | 60 | 1 | 7 | 3,530 | 441.0 | 422.5 | 235 | 185 | |
Fulgar | 3/0 | 19/w | 60 | 1/0 | 7 | 4,460 | 543.4 | 521.1 | 275 | 215 | |
Arca | 4/0 | 19/w | 60 | 2/0 | 7 | 5,390 | 671.2 | 644.6 | 315 | 245 | |
Code Name |
Phase Conductors | Bare Neutral | Weight Per 1000 ft.(lbs) |
Ampacity (Amps) | |||||||
Size AWG or MCM |
Stranding | Insulation thickness (mls) |
Size (AWG) |
*Stranding | Rated strength (lbs) |
XLP | Poly | XLP | Poly | ||
AAC NEUTRAL-MESSENGER | |||||||||||
Haiotis | 6 | solid | 45 | 6 | 7 | 563 | 102.5 | 98.8 | 85 | 70 | |
Patella | 6 | 7/w | 45 | 6 | 7 | 563 | 109.1 | 101.6 | 85 | 70 | |
Fusus | 4 | solid | 45 | 4 | 7 | 881 | 151.9 | 147.6 | 115 | 90 | |
Oyster | 4 | 7/w | 45 | 4 | 7 | 881 | 161.8 | 151.7 | 115 | 90 | |
Clam | 2 | 7/w | 45 | 2 | 7 | 1,350 | 243.2 | 229.2 | 150 | 120 | |
Murex | 1/0 | 7/w | 60 | 1/0 | 7 | 1,990 | 395.1 | 369.4 | 205 | 160 | |
Purpura | 1/0 | 19/w | 60 | 1/0 | 7 | 1,990 | 386.1 | 369.4 | 205 | 160 | |
Nassa | 2/0 | 7/w | 60 | 2/0 | 7 | 2,510 | 485.8 | 455.3 | 235 | 185 | |
Melita | 3/0 | 19/w | 60 | 3/0 | 19 | 3,310 | 585.2 | 562.9 | 275 | 215 | |
Portunus | 4/0 | 19/w | 60 | 4/0 | 19 | 4,020 | 723.9 | 697.3 | 315 | 245 | |
Nannynose | 336.4 | 19/w | 80 | 336.4 | 19 | 6,146 | 1160.4 | 1118.0 | 420 | 325 | |
WITH FULL SIZE ACSR MESSENGER | |||||||||||
Paludina | 6 | solid | 45 | 6 | 6/1 | 1,190 | 114 | 113 | 85 | 70 | |
Voluta | 6 | 7/w | 45 | 6 | 6/1 | 1,190 | 120 | 113 | 85 | 70 | |
Whelk | 4 | solid | 45 | 4 | 6/1 | 1,860 | 169 | 165 | 115 | 90 | |
Periwinkle | 4 | 7/w | 45 | 4 | 6/1 | 1,860 | 176 | 172 | 115 | 90 | |
Conch | 2 | 7/w | 45 | 2 | 6/1 | 2,850 | 267 | 261 | 150 | 120 | |
Neritina | 1/0 | 7/w | 60 | 1/0 | 6/1 | 4,380 | 530 | 419 | 205 | 160 | |
Cenia | 1/0 | 19/w | 60 | 1/0 | 6/1 | 4,380 | 426 | 416 | 205 | 160 | |
Runcina | 2/0 | 7/w | 60 | 2/0 | 6/1 | 5,310 | 530 | 519 | 235 | 185 | |
Triton | 2/0 | 19/w | 60 | 2/0 | 6/1 | 5,310 | 526 | 514 | 235 | 185 | |
Cherrystone | 3/0 | 7/w | 60 | 3/0 | 6/1 | 6,620 | 656 | 643 | 250 | 200 | |
Mursia | 3/0 | 19/w | 60 | 3/0 | 6/1 | 6,620 | 650 | 638 | 250 | 200 | |
Razor | 4/0 | 7/w | 60 | 4/0 | 6/1 | 8,350 | 814 | 799 | 315 | 245 | |
Zuzara | 4/0 | 19/w | 60 | 4/0 | 6/1 | 8,350 | 805 | 792 | 315 | 245 | |
Limpet | 336.4 | 19/w | 80 | 336.4 | 18/1 | 8,680 | 1209 | 1167 | 420 | 325 | |
Code Name |
Phase Conductors | Bare Neutral | Weight Per 1000 ft.(lbs) |
Ampacity (Amps) | |||||||
Size AWG or MCM | Stranding | Insulation thickness (mls) |
Size (AWG) |
Stranding | Rated strength (lbs) |
XLP | Poly | XLP | Poly | ||
WITH ACSR REDUCED SIZE MESSENGER | |||||||||||
Scallop | 4 | Solid | 45 | 6 | 6/1 | 1,190 | 148 | 144 | 115 | 90 | |
Strombus | 4 | 7/w | 45 | 6 | 6/1 | 1,190 | 158 | 148 | 115 | 90 | |
Cockle | 2 | 7/ w | 45 | 4 | 6/1 | 1,860 | 233 | 227 | 150 | 120 | |
Janthina | 1/0 | 7/ w | 60 | 2 | 6/1 | 2,850 | 376 | 365 | 205 | 160 | |
Ranella | 1/0 | 19/ w | 60 | 2 | 6/1 | 2,850 | 372 | 362 | 205 | 160 | |
Cavolinia | 2/0 | 7/ w | 60 | 1 | 6/1 | 3,550 | 462 | 451 | 235 | 185 | |
Clio | 2/0 | 19/ w | 60 | 1 | 6/1 | 3,550 | 458 | 446 | 235 | 185 | |
Sanddollar | 3/0 | 7/ w | 60 | 1/0 | 6/1 | 4,380 | 570 | 557 | 275 | 215 | |
Aega | 3/0 | 19/ w | 60 | 1/0 | 6/1 | 4,380 | 565 | 552 | 275 | 215 | |
Cuttlefish | 4/0 | 7/ w | 60 | 2/0 | 6/1 | 5,310 | 706 | 691 | 315 | 245 | |
Cerapus | 4/0 | 19/ w | 60 | 2/0 | 6/1 | 5,310 | 699 | 684 | 315 | 245 | |
Cowry | 336.4 | 19/ w | 80 | 4/0 | 6/1 | 8,350 | 1135 | 1093 | 420 | 325 | |
3. Quadruplex Service Drop-Aluminum Conductor
Construction:
Conductors are concentrically stranded, compressed 1350-H19 aluminum, insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR, One conductor is manufactured with an extruded ridge for phase identification.
Standards: ASTM B-230, B-231, B-232, B-339 & ICEA S-76 -474
Code Name |
Phase Conductor | Bare Neutral Messenger | Weight Per 1000 ft(lbs) |
Rating(Amps) | ||||||
Size AWG |
Strand | Insulation thickness (mls) |
Size AWG |
Strand | Breaking strength (lbs) |
XLP | POLY | XLP | POLY | |
AAC NEUTRAL-MESSNGER | ||||||||||
Clydesdale | 4 | Solid | 45 | 4 | 7 | 881 | 208 | 201.8 | 100 | 80 |
Pinto | 4 | 7/w | 45 | 4 | 7 | 881 | 223 | 207.9 | 100 | 80 |
Mustang | 2 | 7/w | 45 | 2 | 7 | 1,350 | 333 | 312.6 | 135 | 105 |
Criollo | 1/0 | 19/w | 60 | 1/0 | 7 | 1,990 | 529 | 504.5 | 180 | 140 |
Percheron | 2/0 | 19/w | 60 | 2/0 | 7 | 2,510 | 649 | 620.5 | 205 | 160 |
Hanoverian | 3/0 | 19/w | 60 | 3/0 | 19 | 3,310 | 799 | 765.6 | 235 | 185 |
Oldenburg | 4/0 | 19/w | 60 | 4/0 | 19 | 4,020 | 986 | 946.7 | 275 | 210 |
Lippizaner | 336.4 | 19/w | 80 | 336.4 | 19 | 6,146 | 1,546 | 1,519.2 | 370 | 280 |
ACSR NEUTRAL-MESSNGER | ||||||||||
Morochuca | 6 | Solid | 45 | 6 | 6/1 | 1,190 | 152 | 147.4 | 75 | 60 |
Chola | 6 | 7/w | 45 | 6 | 6/1 | 1,190 | 162 | 151.7 | 75 | 60 |
Morgan | 4 | Solid | 45 | 4 | 6/1 | 1,860 | 226 | 220 | 100 | 80 |
Hackney | 4 | 7/w | 45 | 4 | 6/1 | 1,860 | 241 | 226.1 | 100 | 80 |
Palomino | 2 | 7/w | 45 | 2 | 6/1 | 2,850 | 362 | 342.6 | 135 | 105 |
Costena | 1/0 | 19/w | 60 | 1/0 | 6/1 | 4,380 | 575 | 550.6 | 180 | 140 |
Grullo | 2/0 | 19/w | 60 | 2/0 | 6/1 | 5,310 | 707 | 678.7 | 205 | 160 |
Suffolk | 3/0 | 19/w | 60 | 3/0 | 6/1 | 6,620 | 872 | 838.9 | 235 | 185 |
Appaloosa | 4/0 | 19/w | 60 | 4/0 | 6/1 | 8,350 | 1079 | 1039.2 | 275 | 210 |
Bronco | 336.4 | 19/w | 80 | 336.4 | 18/1 | 8,580 | 1613 | 1568.2 | 370 | 280 |
Gelding | 336.4 | 19/w | 80 | 4/0 | 6/1 | 8,350 | 1548 | 1494.3 | 370 | 280 |
Code Name |
Phase Conductor | Bare Neutral Messenger | Weight Per 1000 ft(lbs) |
Rating(Amps) | ||||||
Size AWG |
Strand | Insulation thickness (mls) |
Size AWG |
Strand | Breaking strength (lbs) |
XLP | POLY | XLP | POLY | |
6201 ALLOY NEUTRAL-MESSENGER | ||||||||||
Bay | 6 | Solid | 45 | 6 | 7 | 1,110 | 145 | 140.0 | 75 | 60 |
French Coach | 6 | 7/w | 45 | 6 | 7 | 1,110 | 155 | 144.3 | 75 | 60 |
German Coach | 4 | Solid | 45 | 4 | 7 | 1,760 | 214 | 208.3 | 100 | 80 |
Arabian | 4 | 7/w | 45 | 4 | 7 | 1,760 | 229 | 214.4 | 100 | 80 |
Belgian | 2 | 7/w | 45 | 2 | 7 | 2,800 | 344 | 323.1 | 135 | 105 |
Shetland | 1/0 | 19/w | 60 | 1/0 | 7 | 4,460 | 546 | 521.1 | 180 | 140 |
Thoroughbred | 2/0 | 19/w | 60 | 2/0 | 7 | 5,390 | 670 | 641.5 | 205 | 160 |
Trotter | 3/0 | 19/w | 60 | 3/0 | 7 | 6,790 | 825 | 791.8 | 235 | 185 |
Walking | 4/0 | 19/w | 60 | 4/0 | 7 | 8,560 | 1019 | 979.7 | 275 |
4. FAQ
(1).Are you a manufacturer or trading company?
We are a leading and profesional manufacturer of cable and wire, including: powe cable up to 500kV, ABC, bare conductor, building wire, control cable, instrument cable, welding cable, rubber cable and so on, with high quality.
(2). Is it sample available?
For stock product, of course, the sample is available for free. The sample will be released against the freight, and freight collect is also acceptable.
(3).What is the MOQ?
It depends on the type and size of the cable and wire, anyway, we will give biggest support to help you satisfy the final client or end user.
(4).Which standards do you comply with when you produce the cable and wire ?
We are able to produce cable and wire according to GB, JB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA, etc.
(5). Can you provide Type Test Report?
Surely, we will give 100% support according to your instruction.
(6). Can we represent your HuaTong CABLE to bid?
Highly welcome! We are looking for agency or partner in your local to promote our products, develop business, accordingly, we will provide nice condictions to make you get rich return.
(7). Which payment term do you accept?
A: The payment term varies with different price level and total amount of each contract.
The following are most common terms:
a. 30% T/T down payment, the balance before delivery.
b. 100% L/C at sight.
c. 30% T/T down payment, the balance against 100% L/C at sight.
d. 30% T/T down payment, 40% before delivery, the balance against the copy of B/L.
e. 30% T/T down payment, the balance against the copy of B/L.
f. 100% down payment.
(8). How about the package?
We can pack our products, by coil, carton, plastic bag, wooden drum/reel, steel-wooden drum/reel, steel drum/reel with strong protection to suit for the long-distance delivery.
(9).What is your quality guarantee period?
Usually, 18months against the date of B/L, 12months against the installation date.
5. Why choosing us— Jinyuan Cable Inc.
(1),More than 30 years experience.
(2) ,100,000m² factory,200 staffs,annual output 100,000 metic tons.
(3),Sound Quality Control
–Material inspection;
–manufacturing inspection;
— Finished products inspection;
— Inspection before delivery.
–Third party inspection.
— Inspection of storage at port of departure.
(4),ISO Certificated.
(5) ,Plenty of material and lobor gurantee the delivery prompt and price competitive.
(6),24/7 service
- Next: Overhead Triplex Service Drop Pagarus Aerial Bundled Cable for Transmission Line
- Previous: Overhead Triplex Service Drop Cyclops Aerial Bundled Cable for Transmission Line
Contact us
Similar Or Related
-
Overhead Triplex Service Drop Gebia Aerial Bundled Cable for Transmission Line
-
Overhead Triplex Service Drop Lalotis Aerial Bundled Cable for Transmission Line
-
Overhead Triplex Service Drop Halotis Aerial Bundled Cable for Transmission Line
-
Overhead Triplex Service Drop Pike Aerial Bundled Cable for Transmission Line
-
Overhead Triplex Service Drop Patella Aerial Bundled Cable for Transmission Line