19X1.5mm2 PVC Insulation Stranded Copper Wire Galvanized Steel Wire Armour Control Cable
Product Description
Application
Control cables are suitable for d. C appication and for rated voltages up to 600/1000V ac, 50Hz–60Hz, as connection wire for electric devices as well as instruments in power station, substations, mines, petrochemical industry etc. As control circuit in control systems for single machine or set of machines, signal system and measuring system.
Product Description:
1) Copper core PVC insulated and PVC sheathed control cable
2) Copper core PVC insulated and PVC sheathed control cable with copper wire braid shielded
3) Copper core PVC insulated and PVC sheathed flexible control cable
4) Copper core PVC insulated and PVC sheathed flexible control cable with braided shield
5) Copper core PVC insulated and PVC sheathed control cable with steel tape armouring
Specification:
Rated voltage: 450/750V, 0.6/1kV
1) Conductor: Solid / stranded copper wire (0.75~2.5mm2~10mm2)
Cores number: 2~61
2) Insulation: PVC/XLPE
3) Screen: Braided copper wire, copper tape or aluminum plastic composite tape
4) Armor: Steel tape or steel wire
5) Sheath: PVC / LSOH
Characticis:
PE insulated cable: 70C
XLPE insulated cable: 90C
PVC insulated cable: 70C&90C
3.Type& Specification
Type |
Name |
Section Area(mm2) |
No. of Core |
Application Site |
KVV |
Copper Conductor,PVC Insulated and Sheathed Control Cable |
0.75 1.0 1.5 2.5 |
2-16 |
Permanent installation indoors,in cable ditches or pipes |
4 6 |
2-14 |
|||
10 |
2-10 |
|||
KVVP |
Copper Conductor,PVC Insulated and Sheathed,Braiding Shielded Control Cable |
0.75 1.0 1.5 2.5 |
2-61 |
Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 |
2-14 |
|||
10 |
2-10 |
|||
KVVP2 |
Copper Conductor,PVC Insulated and Sheathed,Copper-tape Screened Control Cable |
0.75 1.0 1.5 2.5 |
4-10 |
Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 |
7-61 |
|||
10 |
4-10 |
|||
KVV22 |
Copper Conductor,PVC Insulated and Sheathed,Steel tape Armored Control Cable |
0.75 1.0 1.5 2.5 |
7-61 |
Permanent installation indoors,in cable ditches,Be able to withstand stronger external mechanical force |
4 6 |
4-14 |
|||
10 |
4-14 |
|||
KVVR |
Copper Conductor,PVC Insulated and Sheathed,Flexible Control Cable |
0.5-2.5 |
4-61 |
Installation indoors where flexibility and movability are required |
KVVRP |
Copper Conductor,PVC Insulated and Sheathed,Braiding shielded Flexible Control Cable |
0.5 0.75 1.0 |
4-61 |
Installation indoors where flexibility shielding and movability are required |
1.5 2.5 |
4-48 |
|||
KYJV |
Copper Conductor,XLPE Insulated and PVC Sheathed Control Cable |
0.75 1.0 1.5 2.5 |
2-16 |
Permanent installation indoors,in cable ditches or pipes |
4 6 |
2-14 |
|||
10 |
2-10 |
|||
KYJVP |
Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable |
0.75 1.0 1.5 2.5 |
2-61 |
Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 |
2-14 |
|||
10 |
2-10 |
|||
KYJV22 |
Copper Conductor,XLPE Insulated,Steel-tape Armoured,PVC Sheathed Control Cable |
0.75 1.0 1.5 2.5 |
7-61 |
Permanent installation indoors,in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force |
4 6 |
4-14 |
|||
10 |
4-10 |
|||
KYJVP2 |
Copper Conductor,XLPE Insulated,Copper tape Screened,PVC Sheathed Control Cable |
0.75 1.0 1.5 2.5 |
7-61 |
Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 |
4-14 |
|||
10 |
4-10 |
|||
KYJVR |
Copper Conductor,XLPE Insulated,PVC Sheathed Flexible Control Cable |
0.5-2.5 |
4-61 |
Installation indoors where flexibility and movability are required |
KYJVRP |
Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Flexible Control Cable |
0.5 0.75 1.0 |
4-61 |
Installation indoors where flexibility shielding and movability are required |
1.5 2.5 |
4-48 |
4.Service Conditions
(1) The long-time working temperature of conductor of PVC insulated cable is 70oC
The long-time working temperature of conductor of XLPE insulated cable is 90oC
(2) The temperature for laying the cables cannot be lower than 0oC.Permissible bending radius(r):unarmoured cable:r≥6D;(D: outer diameter of the cable);armoured or copper-tape screened cable:r≥12D;shielded flexible cable:r≥6D
- Next: Aluminum Twisted ABC Cable 600/1000V Overhead Cable
- Previous: 600V XLPE Insulated Aerial Bundle Cable with XLPE Insulated Aluminum Alloy Neutral Conductor
Contact us
Similar Or Related
-
10X1.5mm2 Flame Retardant Copper Tape Screen Steel Tape Armored PVC Sheathed Control Cable 0.6/1kV
-
JZ-500 Flexible Copper Control Cable PVC Insulated 300/500V DIN VDE 0285-525
-
0.3/0.5kV 4X4mm2 Copper Wire Braiding PVC Insulation Low Voltage Control Power Cable
-
24X2.5mm2 XLPE Insulated Steel Tape Armoured Control/Instrumentation Cable IEC 60502-1
-
19X1.5mm2 PVC Insulation Stranded Copper Wire Galvanized Steel Wire Armour Control Cable