0.6/1 Kv XLPE Steel Tape Armour 185mm2 240mm2 Aluminum Copper Power Cable
0.6/1 Kv XLPE Steel Tape Armour 185mm2 240mm2 Aluminum Copper Power Cable
LV Cable
Yifang
Yjv22 Yjlv22
ISO, CCC, CE
Bare Copper Wire
Round Wire
PVC
XLPE/PVC
DC & AC
Low and Medium Voltage Cable
Construction, Underground, Industrial, Power Station
Cu or Al
Black
IEC 60502
Double Steel Tape
Yifang
Standard Export Drums
1.5mm2-1000mm2
Zhengzhou, Henan, China
8544492100
Product Description
0.6/1 kV XLPE Steel Tape Armour 185mm2 240mm2 Aluminum Copper Power Cable
Product name
|
Low Voltage 0.6/1 kv xlpe Steel Tape Armoured 185mm2 240mm2 Copper Power Cable
|
Conductor
|
Copper/Aluminum or according to customers’ requests
|
Construction
|
oxygen-free copper conductor,XLPE insulation,steel tape armoured,PVC sheath
|
Voltage
|
0.6/1kv
|
payment terms
|
T/T,L/C
|
MOQ
|
500 meters
|
Port of loading
|
Qingdao |
sample
|
free, but freight prepaid or negotiate
|
Advantages
|
ISO9001 CCC certificated, strict quality control, fast delivery
|
Parameters of Low Voltage 0.6/1 kv xlpe Steel Tape Armoured Copper Power Cable:
1.The Max. permissible continuous operating temperature of conductor is 90ºC;
2.The highest operating temperature of cables is 250ºC when short circuit(5s at most);
3.The cable shall withstand dc voltage of 3.5kv/15min after laying.
4.Laying temperature of cable is not lower than 0 ºC, bending radius of multi-core cable≥15 (D for cable outer diameter, d for the conductor outer diameter);
5.The cable should be 2m far away from thermal pipeline when parallel installing,0.5m distance when cross installing.
6.The distance of each other is not less than 0.1m when parallel installing,the Direct buried depth of 1-35KV cables is not less than 0.7m when Direct burying;
2.The highest operating temperature of cables is 250ºC when short circuit(5s at most);
3.The cable shall withstand dc voltage of 3.5kv/15min after laying.
4.Laying temperature of cable is not lower than 0 ºC, bending radius of multi-core cable≥15 (D for cable outer diameter, d for the conductor outer diameter);
5.The cable should be 2m far away from thermal pipeline when parallel installing,0.5m distance when cross installing.
6.The distance of each other is not less than 0.1m when parallel installing,the Direct buried depth of 1-35KV cables is not less than 0.7m when Direct burying;
Cross Section(mm² )
|
Thickness of inner covering(mm)
|
Thickness of steel tape(mm)
|
Norminal thickness of sheath(mm)
|
Approx. Overall diameter(mm)
|
Approx. Overall diameter(mm)
|
Approx. Weight(kg/km)
|
|
Primary conductor
|
Neutral line(ground line)
|
YJV22
|
|||||
3*4
|
1*2.5
|
0.7
|
1.2
|
0.2
|
1.8
|
16
|
425
|
3*6
|
1*4
|
0.7
|
1.2
|
0.2
|
1.8
|
17
|
527
|
3*10
|
1*6
|
0.7
|
1.2
|
0.2
|
1.8
|
20
|
734
|
3*16
|
1*10
|
0.7
|
1.2
|
0.2
|
1.8
|
23
|
1019
|
3*25
|
1*16
|
0.9
|
1.2
|
0.2
|
1.8
|
26
|
1434
|
3*35
|
1*16
|
0.9
|
1.2
|
0.2
|
1.8
|
28
|
1757
|
3*50
|
1*25
|
1.0
|
1.2
|
0.2
|
1.9
|
30
|
2229
|
3*70
|
1*35
|
1.1
|
1.2
|
0.2
|
2.1
|
35
|
3386
|
3*95
|
1*50
|
1.1
|
1.2
|
0.2
|
2.2
|
39
|
4397
|
3*120
|
1*70
|
1.2
|
1.3
|
0.5
|
2.3
|
43
|
5468
|
3*150
|
1*70
|
1.4
|
1.4
|
0.5
|
2.5
|
47
|
6464
|
3*185
|
1*95
|
1.6
|
1.6
|
0.5
|
2.6
|
52
|
8004
|
3*240
|
1*120
|
1.7
|
1.7
|
0.5
|
2.8
|
57
|
10140
|
3*300
|
1*150
|
1.8
|
1.8
|
0.5
|
3.0
|
63
|
12445
|
- Next: 11kv 12kv XLPE Insulated Mv Power Cable
- Previous: Copper PVC Cable LV (Low Voltage) Aluminium Cable