0.6/1kv 600/1000V Underground Power Cable PVC/XLPE Insulated Swa 3 Cores
Product Description
XLPE insulated power cable has a number of advantages over paper insulated and PVC insulated cable. XLPE cable has high electric
strength, mechanical strength, high-ageing resisting, environmental stress resisting aiti-chemical, corrosion, and simple construction, using
convenient and higher operating of long term temperature. It can be laid with no drop restriction.
Various of flame-retardant XLPE cable can be manufactured with three technology .The flame-retardant cable covers all kinds of low-smoke,
halogen
free, and non-smoke non-halogenated and three classes of A,B,C.
2.Construction
Scope of XLPE cable
Type No. of Core Nominal cross-section
Type | No. of Core | Nominal cross-section |
Cu(AL)/XLPE/PVC(PE) Cu(AL)/XLPE/ATA/PVC(PE)Cu(AL)/XLPE/AWA/PVC(PE) |
1 | 1.5-1000 |
Cu(AL)/XLPE/STA/PVC(PE) Cu(AL)/XLPE/SWA/PVC(PE) |
2,3,4,5 | 1.5-400 |
3+1,4+1,3+2 | 2.5-400 |
Cross-section area of neutral conductor
In 3+1cores and 3+2cores should conform to specification of following table:
Nominal cross-section | Main core | 2.5 | 4 | 6 | 10 | 16 | 25 | 35 | 50 |
Neutral core | 1.5 | 2.5 | 4 | 6 | 10 | 16 | 16 | 25 | |
Nominal cross-section | Main core | 70 | 95 | 120 | 150 | 185 | 240 | 300 | 400 |
Neutral core | 35 | 50 | 70 | 70 | 95 | 120 | 150 | 185 |
3. Characteristic
D.C Resistance of finished cable at 20ºC per km is not more than the following:
Nominal cross-section mm2 | 15 | 2.5 | 4 | 6 | 10 | 16 | 25 |
Cu core | 12.1 | 7.41 | 4.61 | 3.08 | 1.83 | 1.15 | 0.727 |
Al core | 18.1 | 12.1 | 7.41 | 4.61 | 3.08 | 1.91 | 1.20 |
Nominal cross-section mm2 | 35 | 50 | 70 | 95 | 120 | 150 | 185 |
Cu core | 0.524 | 0.387 | 0.268 | 0.193 | 0.153 | 0.124 | 0.0991 |
Al core | 0.868 | 0.641 | 0.443 | 0.320 | 0.253 | 0.206 | 0.164 |
Nominal cross-section mm2 | 240 | 300 | 400 | 500 | 630 | 800 | 1000 |
Cu core | 0.0754 | 0.0601 | 0.0470 | 0.0366 | 0.0283 | 0.0221 | 0.0176 |
Al core | 0.125 | 0.100 | 0.0778 | 0.0605 | 0.0469 | 0.0367 | 0.0291 |
Voltage test:
Each drum of finished cable should withstand power frequency voltage 3.5kV for 5 minutes,the insulation is not breakdown.
Service conditions and operation parameters of Cable:
The cable is applied to fixed installation for rated voltage 0.6/1kV of power transportation and distribution line.
Max. rated temperature of conductor. nominal operating 90ºC
Short circuit: max. for 5 sec.250ºC
The cable can be laid without drop restriction, and the environment temperature shall not be lower than 0ºC.
4.Standard
Our XLPE cable can be manufactured according to the company’s specification which is equivalent to IEC 60502,IEC60332,IEC60754.
Some indexes are superior to above international standard.
- Next: Nyy-J Copper Copper Conductor, PVC Insulation, PVC Outer Sheath
- Previous: 600/1000V Cu/XLPE/PVC/ Swa/PVC Power Cable 4X4mm2
Contact us
Similar Or Related
-
10X1.5mm2 Flame Retardant Copper Tape Screen Steel Tape Armored PVC Sheathed Control Cable 0.6/1kV
-
JZ-500 Flexible Copper Control Cable PVC Insulated 300/500V DIN VDE 0285-525
-
0.3/0.5kV 4X4mm2 Copper Wire Braiding PVC Insulation Low Voltage Control Power Cable
-
24X2.5mm2 XLPE Insulated Steel Tape Armoured Control/Instrumentation Cable IEC 60502-1
-
0.6/1kv 600/1000V Underground Power Cable PVC/XLPE Insulated Swa 3 Cores