AAC Conductor, All Aluminium Conductor (AS 1531)
Product Description
AAC conductor is widely used in power transmission lines with various voltage levels.
Since they have such good characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical teatures exist.
1. Specification:
All aluminium conductor (AAC)
2. Elative manufacturing standards:
AS 1531: Conductors-Bare overhead-Aluminium and aluminium alloy
3. Construction:
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corrosion or infusion of the complete cable with grease.
Notes:
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.
Code Name | Stranding and wire diameter | Cross- sectional area | Approximate mass | Calculated breaking load (CBL) | Equiv. aluminium area | DC resist. at 20°C |
mm | mm2 | kg/km | kN | mm2 | Ω/km | |
Leo | 7.5 | 34.36 | 94.3 | 5.71 | 33.9 | 0.833 |
Leonids | 8.25 | 41.58 | 113 | 6.72 | 41.1 | 0.689 |
Libra | 9.0 | 49.48 | 135 | 7.98 | 48.9 | 0.579 |
Mars | 11.3 | 77.28 | 211 | 11.8 | 76.3 | 0.370 |
Mercury | 13.5 | 111.3 | 304 | 16.9 | 110 | 0.258 |
Moon | 14.3 | 124.0 | 339 | 18.9 | 122 | 0.232 |
Neptune | 16.3 | 157.6 | 433 | 24.7 | 154 | 0.183 |
Orion | 17.5 | 182.8 | 503 | 28.7 | 180 | 0.157 |
Pluto | 18.8 | 209.8 | 576 | 31.9 | 206 | 0.137 |
Saturn | 21.0 | 261.6 | 721 | 42.2 | 256 | 0.110 |
Sirius | 22.8 | 307.0 | 845 | 48.2 | 301 | 0.094 |
Taurus | 23.8 | 336.7 | 924 | 51.3 | 331 | 0.0857 |
Triton | 26.3 | 408.5 | 1120 | 62.2 | 400 | 0.0706 |
Uranus | 29.3 | 506.1 | 1400 | 75.2 | 495 | 0.0572 |
Ursula | 31.5 | 586.9 | 1620 | 87.3 | 574 | 0.0493 |
Venus | 33.8 | 673.4 | 1860 | 97.2 | 659 | 0.0429 |
- Next: ACSR/Aw, Aluminium Conductors Aluminium Clad Steel Reinforced (ASTM B 549)
- Previous: ACSR, Conductor, Aluminium Conductors Steel Reinforced (UNE 21018)
Contact us
Similar Or Related
-
AAC 95mm2 19/2.52 Conductor TIS 85-2548 for Transmission and distribution line
-
CU/XLPE/CTS/PVC 6.35/11kV Single Core Aluminum Power Cable IEC 60502-2
-
Al/XLPE/CTS/PVC 19/33kV 36kV Single Core Aluminum Power Cable IEC 60502-2
-
Yjlv XLPE Insulated and PVC Sheathed Power Cable Alu/XLPE/PVC
-
(AL/XLPE//SWA/PVC) Aluminum Conductor XLPE Insulated PVC Sheathed Yjlv22 Power Cable