High Voltage Single Copper Core Wire Armoured XLPE Cable

Product Description
Standard:
35kV And Below PVC/XLPE Power Cables is manufacture under GB/T12706-2008 standard (Mainly complying with IEC 60502 standard, also can be produced according to OEM requirements and other standards, such as BS standard, DIN standard, ASTM standard, etc. )
Using features:
Rated voltage: U0/U: 26/35kV (12/20kV), 8.7/15kV (8.7/10kV), 6/10kV (6/6kV), 3.6/6kV, 1.8/3kV
The highest allowed operating temperature of conductor is no more than 250 ° C
The environment temperature should be no lower than 0 ° C when lay. Otherwise it should be preheated.
The cable is laid without horizontal drop limit. The Min. Bending radius of three-core cable should be no smaller than 12 times of cable outer diameter.
Standard:
| Type | Name | Application | |
| Cu | Al | ||
| YJV | YJLV | XLPE insulated, PVC sheathed power cable | Can be laid in indoor, outdoor, tunnels, cable canals, reinforeced concrete pipelines and loose soil. Cable can not undertake mechanic force, but can undertake certain tractional force. |
| YJV22 | YJLV22 | XLPE insulated, steel tape armored and PVC sheathed power cable | Laid underground. Cable can undertake outer mechanic force, but can not undertake large tractional force. |
| YJY23 | YJLY23 | XLPE insulated, steel tape armored and PVC sheathed power cable | Laid underground. Cable can undertake outer mechanic force, but can not undertake large tractional force. |
| YJV32 | YJLV32 | XLPE insulated, steel wire armored and PVC sheathed power cable | Can be laid in indoor, tunnels and mines. Cable can undertake outer mechanic force and fairly large tractional force. |
| YJY | YJLY | XLPE insulated, PE sheathed power cable | Can be laid in indoor, tunnels and piplines. Cables can not undertake outer mechanic force. |
| YJVR | Soft core, XLPE insulated, PVC sheathed power cable | Can be laid in indoor, tunnels and piplines. Cables can not undertake outer mechanic force and large tractional force. |
| Type | Name | Usage |
| VV | PVC insulated PVC sheathed power cable | Can be laid at indoor, tunnel and tube. Cable cannot under take mechanism outside force |
| VLV | ||
| VY | PVC insulated and PE sheathed power cable | Can be laid at indoor, tunnel tube and serious polluted places. Cable cannot undertake mechanism outside force |
| VLY | ||
| PVC insulated steel belt armored and PVC sheathed power cable | Can be laid at indoor, tunnel tube and mining well. Cable cannot undertake mechanism outside force | |
| VLV22 | ||
| VV23 | PVC insulated steel belt armored and PE sheathed power cable | Can be laid at indoor, tunnel tube mining well and serious polluted places. Cable cannot undertake mechanism outside force |
| VLV23 | ||
| VV32 | PVC insulated fine steel wire armored PVC sheathed power cable | Can be laid at indoor, underground and mining well. Cable can undertake mechanism outside force |
| VLV32 | ||
| VV33 | PVC insulated fine steel wire armored PE sheathed power cable | Can be laid at indoor, underground. Cable can under take mechanism outside force |
| VLV33 | ||
| VV42 | PVC insulated thick steel wire armored PVC sheathed power cable | Can be laid at indoor, underground, mining well. Cable can under take mechanism outside force |
| VLV42 | ||
| VV43 | PVC insulated fine steel wire armored PE sheathed power cable | Can be laid at indoor, underground, mining well and the places of be terrible polluted. Cable can under take mechanism outside force |
Contact us
Similar Or Related
- No related articles

