Hot Selling Product ACSR Aluminum Conductor (LJ/LGJ)
Product Description
Products range
1)AAAC(All Aluminum Alloy Conductors)
2)ACSR(Aluminum Conductor Steel Reinforced)
3)AAC(All Aluminum Conductors)
4)AACSR(Aluminum Alloy Conductors Steel Reinforced)
5)ACSR/AW(Aluminum Conductor Aluminum Clad Steel Reinforced)
Standard
AAAC, AAC, ACSR, AACSR, ACSR/AW Conductors can be produced fully in accordance with international standard such as IEC, BS, ASTM, DIN, JIS, NF, CSA, AS/NZS.
Construction:
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease.
Specifications:
ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)
Notes:
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.
Application
The conductors are suitable for use in spans on wood poles, transmission towers,and other structures where tensile strength and temperature ratings are not required. Application range from extra high voltage(EHV) transmission lines to sub-service spans at distribution or utilization voltages on private premises. AAC(All aluminum conductor) is the most economical bare overhead conductor due to its lighter weight. It offers easier handing during installation and use of simpler fittings. The conductor is corrosion resistant due to its homogeneous construction.
Property
Aluminum 1350 wires are concentrically stranded and wrapped helically around a central wire. Each successive layer has six wires more than the previous underlying layer. Outer layer is right hand lay and reversed in successive layers.
Standard:
ASTM B230,B231,B400 Standard
Code word |
Size of Conductor |
Stranding and Wire Diameter |
Overall Diameter |
Max.D.C. Resistance at 20°C |
Code word |
Size of Conductor |
Stranding and Wire Diameter |
Overall Diameter |
Max.D.C. Resistance at 20°C |
AWG or MCM |
mm |
mm |
ohm/km |
AWG or MCM |
mm |
mm |
ohm/km |
||
Peachbell |
6 |
7/1.554 |
4.67 |
2.1692 |
Verbena |
700 |
37/3.493 |
24.45 |
0.0813 |
Rose |
4 |
7/1.961 |
5.89 |
1.3624 |
Nasturtium |
715.5 |
61/2.75 |
24.76 |
0.0795 |
Lris |
2 |
7/2.474 |
7.42 |
0.8577 |
Violet |
715.5 |
37/3.533 |
24.74 |
0.0795 |
Pansey |
1 |
7/2.776 |
8.33 |
0.6801 |
Cattail |
750 |
61/2.817 |
25.35 |
0.0759 |
Poppy |
1/0 |
7/3.119 |
9.36 |
0.5390 |
Petunia |
750 |
37/3.617 |
25.32 |
0.0759 |
Aster |
2/0 |
7/3.503 |
10.51 |
0.4276 |
Lilac |
795 |
61/2.90 |
26.11 |
0.0715 |
Phlox |
3/0 |
7/3.932 |
11.80 |
0.3390 |
Arbutus |
795 |
37/3.724 |
26.06 |
0.0715 |
Oxlip |
4/0 |
7/4.417 |
13.26 |
0.2688 |
Snapdragon |
900 |
61/3.086 |
27.78 |
0.0632 |
Valerian |
250 |
19/2.913 |
14.57 |
0.2275 |
Cockscomb |
900 |
37/3.962 |
27.73 |
0.0632 |
Sneezewort |
250 |
7/4.80 |
14.4 |
0.2275 |
Goldenrod |
954 |
61/3.177 |
28.6 |
0.0596 |
Laurel |
266.8 |
19/3.01 |
15.05 |
0.2133 |
Magnolia |
954 |
37/4.079 |
28.55 |
0.0596 |
Daisy |
266.8 |
7/4.96 |
14.9 |
0.2133 |
Camellia |
1000 |
61/3.251 |
29.36 |
0.0569 |
Peony |
300 |
19/3.193 |
15.97 |
0.1896 |
Hawkweed |
1000 |
37/4.176 |
29.23 |
0.0569 |
Tulip |
336.4 |
19/3.381 |
16.91 |
0.1691 |
Larkspur |
1033.5 |
61/3.307 |
29.76 |
0.0550 |
Daffodil |
350 |
19/3.447 |
17.24 |
0.1625 |
Bluebell |
1033.5 |
37/4.244 |
29.72 |
0.0550 |
Canna |
397.5 |
19/3.673 |
18.36 |
0.1431 |
Marigold |
1113 |
61/3.432 |
30.89 |
0.0511 |
Goldentuft |
450 |
19/3.909 |
19.55 |
0.1264 |
Hawthorn |
1192.5 |
61/3.551 |
31.05 |
0.0477 |
Syringa |
477 |
37/2.882 |
20.19 |
0.1193 |
Narcissus |
1272 |
61/3.668 |
33.02 |
0.0477 |
Cosmos |
477 |
19/4.023 |
20.12 |
0.1193 |
Columbine |
1351.5 |
61/3.78 |
34.01 |
0.0421 |
Hyacinth |
500 |
37/2.951 |
20.65 |
0.1138 |
Carnation |
1431 |
61/3.89 |
35.03 |
0.0398 |
Zinnia |
500 |
19/4.12 |
20.6 |
0.1138 |
Gladiolus |
1510.5 |
61/4.00 |
35.09 |
0.0376 |
Dahlia |
556.5 |
19/4.346 |
21.73 |
0.1022 |
Coreopsis |
1590 |
61/4.099 |
36.51 |
0.03568 |
Mistletoe |
556.5 |
37/3.114 |
21.79 |
0.1022 |
Jessamine |
1750 |
61/4.302 |
38.72 |
0.0325 |
Meadowsweet |
600 |
37/3.233 |
22.63 |
0.0948 |
Cowslip |
2000 |
91/3.76 |
41.40 |
0.02866 |
Orchid |
636 |
37/3.33 |
23.31 |
0.0894 |
Lupine |
2500 |
91/4.21 |
46.30 |
0.0230 |
Heuchera |
650 |
37/3.366 |
23.56 |
0.0875 |
Trillium |
3000 |
127/3.90 |
50.75 |
0.0192 |
Flag |
700 |
61/2.72 |
24.48 |
0.0813 |
Bluebonnet |
3500 |
127/4.21 |
54.80 |
0.01653 |
Contact us
Similar Or Related
-
200 Sqmm. Stranded Aluminum Conductor Steel Reinforced (ACSR) Panther 200 MMSQ
-
ACSR 240/40 Aluminum Conductor Steel Reinforced Bare Conductor for Busbar Connection
-
ACSR 490/65 Aluminum Conductor Steel Reinforced Bare Conductor for Busbar Connection
-
100 mm2 Stranded Aluminum DOG Conductor Steel Reinforced (ACSR)
-
ACSR 305/40 Aluminum Conductor Steel Reinforced Bare Conductor for Busbar Connection