450/750V PVC Insulated Building Wire
More product about Copper Wire450/750V PVC Insulated Building Wire
Insulated
Stranded
Building
Copper
PVC
PVC
Round Wire
Building
ISO9001, CE, CCC
Jinshui
JINSHUI
Drum
Zhengzhou Henan
4101361940
Product Description
PVC Wire is used for lighting, electronic equipment, instument and communication equipment with rated voltage 450/750V or less
Specification:
1. The rated voltage of the wires should equal to or higher then the rated voltage of the system when wires are used at AC system. If the wires are used at DC system, the rated voltage of system should lower then 1.5 times as high as rated voltage of cable and wires. The working voltage of the system could be 1.1 times as high as the rated voltage of the cable.
2. The long term working temperature should lower then 70oC. The working temperature of BV-90 should lower then 90oC. And the laying temperature should higher then 0oC.
3. The curve diameter of the wire should longer than 8 times of the diameter of the outer diameter of cable and wires if their outer diameter is 25 mm or above. If the diameter of cable and wires is above 25 mm, the curve diameter should be at least 12 times of the outer diameter of the cable and wires.
Specification:
1. The rated voltage of the wires should equal to or higher then the rated voltage of the system when wires are used at AC system. If the wires are used at DC system, the rated voltage of system should lower then 1.5 times as high as rated voltage of cable and wires. The working voltage of the system could be 1.1 times as high as the rated voltage of the cable.
2. The long term working temperature should lower then 70oC. The working temperature of BV-90 should lower then 90oC. And the laying temperature should higher then 0oC.
3. The curve diameter of the wire should longer than 8 times of the diameter of the outer diameter of cable and wires if their outer diameter is 25 mm or above. If the diameter of cable and wires is above 25 mm, the curve diameter should be at least 12 times of the outer diameter of the cable and wires.
Type | Name | Laying place and requirement | Long term working Temperature0C |
60227IEC01 05 BV BLV |
Copper conductor PVC insulated wires Aluminum conductor PVC insulated wires |
Fixed laid indoors Conduit etc. |
70 |
60227IEC07 (BV-90) |
Heat resistant copper conductor PVC insulated wire at 90 0C | Mainly be laid at the places of high temperature environment and can be laid indoors ,conduits. |
90 |
BVR | Copper conductor PVC insulated flexible cable | Be for laying permanent place where flexible required. |
70 |
60227IEC10 (BVV) BVV |
Copper conductor PVC insulated PVC sheathed round wires | Fixed laid, fit for the places with high mechanical protection and moisture place, can be laid in the air or underground. |
70 |
BLVV | Aluminum conductor PVC insulated PVC sheathed round wires | ||
BVVB | Copper conductor PVC insulated PVC sheathed flat wires | ||
BLVVB | Aluminum conductor PVC insulated PVC sheathed flat wires | ||
60227IEC02(RV) 60227IEC06(RV) |
Copper conductor PVC insulated flexible connector wire | Mainly used at middle and light style moving electronics, home appliances, power and lighting and the places where flexible required |
70 |
60227IEC42(RVB) | Copper conductor PVC insulated flat flexible connector wire | ||
RVS | Copper conductor PVC insulated flexible twisting connector wire | ||
60227IEC52(RVV) 60227IEC53 |
Copper conductor PVC insulated PVC sheathed round flexible connector wire | ||
60227IEC08 (RV-90) |
Cu conductor heat resistant PVC insulated flexible connector wire at 90 0C | Mainly used at the places where heat resistance is required | 90 |
Similar Or Related
Fire Resistant Marine Insulated PVC Sheath Jacket Underground Armoured Overhead Electrical Cables XLPE Copper Aluminum Electric Wire Power Cable
Read More
Low Voltage Unarmored Yjv Cable 0.6/1kv
Read More
300V 500V 450V 750V Thhn Thwn House Building Wiring Fire Retardant Nylon PE XLPE PVC Insulated Flexible Copper Electrical Cable Electric Wire