25mm 70mm Copper Earth Grounding Cable Copper Conductor
More product about CableProduct Description
Characteristics of Cable
1.Max Long-time operating temperature of PVC insulated cable is 70°C,XLPE 90°C
2.Installing temperature of cable should not be less than 0°C
3.Max short-circuit temperature is:PVC not exceed 160°C,XLPE 250°C,Not more than5 Sec.
4.Permitting bending radius cable: Not less than 10 D times (D:external diameter of cable)
5.Perfect chemical stability, resistant against acids, alkali, grease and organic solvents, and flamer retardant
1Core (sqmm) |
2Core (sqmm) |
3core (sqmm) |
3c+1c (sqmm) |
4core (sqmm) |
3c+2c (sqmm) |
4c+1c (sqmm) |
5core (sqmm) |
1×1.5 | 2×1.5 | 3×1.5 | 3×2.5+1×1.5 | 4×1.5 | 3×2.5+2×1.5 | 43×2.5+1×1.5 | 5×1.5 |
1×2.5 | 2×2.5 | 3×2.5 | 3×4+1×2.5 | 4×2.5 | 3×4+2×2.5 | 4×4+1×2.5 | 5×2.5 |
1×4 | 2×4 | 3×4 | 3×6+1×4 | 4×4 | 3×6+2×4 | 4×6+1×4 | 5×4 |
1×6 | 2×6 | 3×6 | 3×10+1×6 | 4×6 | 3×10+2×6 | 4×10+1×6 | 5×6 |
1×10 | 2×10 | 3×10 | 3×16+1×6 | 4×10 | 3×16+2×6 | 4×16+1×6 | 5×10 |
1×16 | 2×16 | 3×16 | 3×25+1×10 | 4×16 | 3×25+2×10 | 4×25+1×10 | 5×16 |
1×25 | 2×25 | 3×25 | 3×35+1×10 | 4×25 | 3×35+2×10 | 4×35+1×10 | 5×25 |
1×35 | 2×35 | 3×35 | 3×50+1×16 | 4×35 | 3×50+2×16 | 4×50+1×16 | 5×35 |
1×50 | 2×50 | 3×50 | 3×70+1×25 | 4×50 | 3×70+2×25 | 4×70+1×25 | 5×50 |
1×70 | 2×70 | 3×70 | 3×95+1×35 | 4×70 | 3×95+2×35 | 4×95+1×35 | 5×70 |
1×95 | 2×95 | 3×95 | 3×120+1×35 | 4×95 | 3×120+2×35 | 4×120+1×35 | 5×95 |
1×120 | 2×120 | 3×120 | 3×150+1×50 | 4×120 | 3×150+2×50 | 4×150+1×50 | 5×120 |
1×150 | 2×150 | 3×150 | 3×185+1×50 | 4×150 | 3×185+2×50 | 4×185+1×50 | 5×150 |
1×185 | 2×185 | 3×185 | 3×240+1×70 | 4×185 | 3×240+2×70 | 4×240+1×70 | 5×185 |
1×240 | 2×240 | 3×240 | 3×300+1×95 | 4×240 | 3×300+2×95 | 4×300+1×95 | – |
1×300 | 2×300 | 3×300 | 3×400+1×150 | 4×300 | 3×400+2×150 | 4×400+1×150 | – |
1×400 | 2×400 | 3×400 | – | 4×400 | – | – | – |
Cross Section of Conductor | No. of Wires | Thickness of Insulation | Thickness of Inner Sheath | Thickness of Steel Tape | No./Dia. Of Steel Wires | Thickness of Sheath | Overall Diameter | Approx. Net Weight | |||||
STA | SWA | ||||||||||||
STA | SWA | STA | SWA | STA | SWA | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||
mm2 | – | mm | mm | mm | No./mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km |
Three Cores | |||||||||||||
3×35 | 16 | 1.2 | 1 | 0.2 | 38/1.6 | 1.8 | 1.9 | 24.7 | 28.2 | 912 | 1591 | 1447 | 2126 |
3×50 | 18 | 1.4 | 1 | 0.2 | 46/1.6 | 1.9 | 2 | 29.3 | 32.8 | 1202 | 2105 | 1842 | 2745 |
3×70 | 18 | 1.4 | 1.2 | 0.2 | 41/2.0 | 2.0 | 2.2 | 32.5 | 37.1 | 1520 | 2820 | 2475 | 3775 |
3×95 | 36 | 1.6 | 1.2 | 0.5 | 46/2.0 | 2.1 | 2.3 | 36.5 | 40.8 | 2241 | 4049 | 2989 | 4797 |
3×120 | 36 | 1.6 | 1.2 | 0.5 | 50/2.0 | 2.2 | 2.4 | 39.8 | 44.1 | 2617 | 4895 | 3435 | 5713 |
3×150 | 36 | 1.8 | 1.2 | 0.5 | 43/2.5 | 2.3 | 2.5 | 42.4 | 47.8 | 3019 | 5846 | 4258 | 7085 |
3×185 | 36 | 2 | 1.4 | 0.5 | 50/2.5 | 2.5 | 2.7 | 48.8 | 54.2 | 3783 | 7264 | 5219 | 8700 |
3×240 | 60 | 2.2 | 1.6 | 0.5 | 58/2.5 | 2.8 | 2.9 | 56 | 61.3 | 4790 | 9390 | 6444 | 11044 |
3×300 | 60 | 2.4 | 1.6 | 0.5 | 61/2.5 | 2.9 | 3.1 | 59.3 | 64.7 | 5594 | 11345 | 7458 | 13209 |
Four Cores with Reduced Neutral | |||||||||||||
3×35+16 | 16-7 | 1.2-1 | 1 | 0.2 | 43/1.6 | 1.9 | 2 | 28.5 | 31.3 | 1107 | 1528 | 1705 | 2469 |
3×50+25 | 18-16 | 1.4-1.2 | 1.2 | 0.2 | 40/2.0 | 2.0 | 2.1 | 32.2 | 36.1 | 1410 | 2044 | 2326 | 3388 |
3×70+35 | 18-16 | 1.4-1.2 | 1.2 | 0.2 | 44/2.0 | 2.0 | 2.2 | 35.2 | 39.3 | 1733 | 2801 | 2762 | 4285 |
3×95+50 | 36-18 | 1.6-1.4 | 1.2 | 0.5 | 41/2.5 | 2.3 | 2.5 | 42.5 | 46.3 | 2656 | 3820 | 3816 | 5925 |
3×120+70 | 36-18 | 1.6-1.4 | 1.4 | 0.5 | 45/2.5 | 2.4 | 2.6 | 45.6 | 49.4 | 3137 | 4777 | 4391 | 7103 |
3×150+70 | 36-18 | 1.8-1.4 | 1.4 | 0.5 | 49/2.5 | 2.6 | 2.7 | 49.9 | 53.6 | 3660 | 5709 | 5043 | 8272 |
3×185+95 | 36-36 | 2-1.6 | 1.4 | 0.5 | 55/2.5 | 2.6 | 2.9 | 54.5 | 58.5 | 3445 | 7171 | 5902 | 9987 |
3×240+120 | 60-36 | 2.2-1.6 | 1.6 | 0.5 | 62/2.5 | 2.9 | 3.1 | 61.6 | 65.3 | 5441 | 9272 | 7174 | 12552 |
3×300+150 | 60-36 | 1.4-1.8 | 1.6 | 0.5 | 67/2.5 | 3.8 | 3.2 | 65.9 | 69.6 | 6494 | 11546 | 8355 | 15067 |
Four Cores | |||||||||||||
4×25 | 16 | 1.2 | 1 | 0.2 | 38/1.6 | 1.8 | 1.9 | 25.3 | 28 | 934 | 1576 | 1450 | 2092 |
4×35 | 16 | 1.2 | 1 | 0.2 | 41/1.6 | 1.8 | 1.9 | 27.4 | 30.2 | 1120 | 2017 | 1681 | 2578 |
4×50 | 18 | 1.4 | 1 | 0.2 | 39/2.0 | 2 | 2.1 | 31.6 | 35.6 | 1454 | 2658 | 2336 | 3540 |
4×70 | 18 | 1.4 | 1.2 | 0.5 | 43/2.0 | 2.1 | 2.2 | 36.3 | 39 | 2183 | 3916 | 2840 | 4573 |
4×95 | 36 | 1.6 | 1.2 | 0.5 | 50/2.0 | 2.3 | 2.4 | 40.6 | 44.1 | 2748 | 5160 | 3545 | 5957 |
4×120 | 36 | 1.6 | 1.4 | 0.5 | 42/2.5 | 2.4 | 2.5 | 43.9 | 47.2 | 3237 | 6214 | 4334 | 7372 |
4×150 | 36 | 1.8 | 1.4 | 0.5 | 48/2.5 | 2.5 | 2.6 | 48.3 | 52 | 3853 | 7622 | 5148 | 8917 |
4×185 | 36 | 2 | 1.6 | 0.5 | 54/2.5 | 2.7 | 2.8 | 54.3 | 57.6 | 4756 | 9323 | 6132 | 10774 |
4×240 | 60 | 2.2 | 1.6 | 0.5 | 59/2.5 | 2.9 | 3 | 59.2 | 62.9 | 5774 | 11906 | 7374 | 13506 |
4×300 | 60 | 2.4 | 1.6 | 0.5 | 65/2.5 | 3 | 3.2 | 64.3 | 68.1 | 6922 | 14589 | 8624 | 16291 |
Product Pictures:
Packing and Delivery:
Our Company:
People’s Cable Group Co., Ltd, a professional wires and cables manufacturer for 27 years in China. we mainly produce power cables, control cables, aerial overhead cables(ABC, AAC ACSR and AAAC cables) etc. Standards Supported: ASTM, BS, CSA, IEC, DIN and GB etc.
1. Factory: 160000 square meters, available for OEM;
2. Lead time: 5-7 working days after payment received;
3. Authentication: TUV, OHSAS, CCC, ISO9001:2008;
4. Guarantee: 20 years;
5. QC inspection: Strict inspection before delivery;
After-sales Service:
1. All our cables will be tested well in production and before delivery.
2. Please contact us if any problem, we will respond within 24 hours.
FAQ:
(1)When can I get the price?
We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please call us or tell us in your e-mail so that we will regard your inquiry priority.
(2)How can I get a sample to check your quality?
After price confirmation, you can require for samples to check our quality. Sample is free, but the freight charge should be paid.
(3)How long can I expect to get the sample?
After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7days. The samples will be sent to you via express and arrive in 3-5 days. You can use your own express account or prepay us if you do not have an account.
(4)What about the lead time for mass production?
Honestly, it depends on the order quantity and the season you place the order. The best record we keep is delivering 10 kilometers cable within a week. Generally speaking, we suggest that you start inquiry two months before the date you would like to get the products at your country.
Contact Information:
Ivan Fan | Sales Manager | People’s Cable Group
Web: www.vwcable.com
If you have any questions, please contact me, I will reply you as soon as possible.
Welcome your inquiry.