2 Core 1kv Stranded Copper XLPE Insulation Concentric Service Cable 10mm Sq
More product about Concentric Cable2 Core 1kv Stranded Copper XLPE Insulation Concentric Service Cable 10mm Sq
Concentric Service Cable
OEM/Hongda
Concentric Service Cable
ISO, CCC
Bare Copper Wire
Round Wire
PVC
XLPE
DC & AC
Low and Medium Voltage Cable
Construction, Overhead, Underground, Industrial, Power Station
as Your Need
OEM
in Drum or in Coil
16
Henan
8544492100
Product Description
2 Core 1kV Stranded Copper XLPE Insulation Concentric Service Cable 10mm SQ
CONSTRUCTION CHARACTERISTICS
Type of cable | Concentric |
Conductor material | Bare annealed copper stranded |
Type of conductor | Circular, stranded, class 2 |
Insulation | XLPE (chemical) |
Outer sheath | XLPE/PE/PVC (UV resistant) |
Rated Voltage Uo/U (Um) | 0.6/1 kV |
Identification of the Insulated Conductors:
The identification is made by the color of the insulation material, being:
- Single-phase conductor: black
- Two-phase conductors: black and red
- Three-phase conductors: black, red and white
Max conductor temperatures
90° at continuous service, 130° overloaded and 250° at short-circuit.
DIMENSIONAL CHARACTERISTICS
Concentric Cable | 1×6+6 | 1×10+10 | 1×16+16 |
Number of cores | 1 | 1 | 1 |
Nominal insulation thickness | 1.0mm | 1.0mm | 1.0mm |
Protective Covering Nominal Thickness | 1.2mm | 1.2mm | 1.2mm |
Conductor diameter | 3.12mm | 4.05mm | 5.1mm |
Conductor cross-section | 6mm² | 10mm² | 16mm² |
Nominal outer diameter | 9.1mm | 10.4mm | 11.8mm |
Approximate weight | 155kg/km | 245kg/km | 359kg/km |
Max. DC resistance of the conductor at 20°C | 3.08Ω/km | 1.83Ω/km | 1.15Ω/km |
600/1000V SINGLE PHASE CONCENTRIC CABLES WITH STRANDED COPPER
CONDUCTORS AND COPPER WIRE NEUTRAL CONDUCTORS
PHASE CONDUCTOR | CONCENTRIC NEUTRAL CONDUCTOR NUMBER AND APPROX. DIAMETER OF WIRES |
LAY LENGTHS |
THICKNESS OF OVER SHEATH |
APPROX. OVERALL DIAMETER OF CABLE |
max.d.c. CONDUCTOR RESISTANCE PER 1000 m OF CABLEAT 20 ºC |
||||
Nominal area | Number and approximate diameter of wires |
Thicknesof insulation | Phase | Neutral | |||||
mm2 | mm | mm | mm | min mm |
max mm |
mm | mm | WΩ | WΩ |
4 | 7/0.85 | 1.55 | 24/0.85 | 59 | 118 | 1.4 | 9.75 | 4.61 | 1.343 |
6 | 7/1.04 | 1.55 | 26/0.85 | 63 | 127 | 1.4 | 10.72 | 3.08 | 1.240 |
10 | 7/1.35 | 1.55 | 29/0.85 | 71 | 142 | 1.4 | 11.73 | 1.83 | 1.151 |
16 | 7/1.70 | 1.55 | 26/1.13 | 84 | 167 | 1.4 | 12.78 | 1.15 | 1.007 4 |
25 | 7/2.14 | 1.60 | 29/1.13 | 95 | 190 | 1.5 | 14.88 | 0.727 | 0.629 |
35 | 19/1.53 | 1.65 | 28/1.35 | 109 | 218 | 1.6 | 16.75 | 0.524 | 0.473 |
For more information, don’t hesitate to contact Vivian Yuan on +86-18339931106