15kv Copper XLPE Insulated Swa Steel Wire Armored Power Cable

15kv Copper XLPE Insulated Swa Steel Wire Armored Power Cable
yjv
Construction, Underground, Industrial, Power Station
Industrial Power Station
Low and Medium Voltage Cable
DC Cable
XLPE
PVC
Round Wire
Bare Copper Wire
ISO, CCC
YJLV22
Jytop
Stranded
Based on Client's Requirement
IEC60502,Ce. BS, DIN, ASTM, GB12706-2008 Standard
JYTOP
Packed in Reels
any Third party Pre-shipment inspection
Zhengzhou, China
8544601200

Product Description


0.6/1kv 4 Core PVC Insualted and Sheathed armoured Copper electric cable / Power Cable

1 Information
a, Number of cores:
1, 2, 3, 3+1, 3+2, 3+3, 4, 4+1, 4+2, 5 and so on.
Core NO. & Nominal Cross-section Area as reference:

No. of Core 1 2 3 3+1 4 3+2 4+1
Section
Area
(mm2)
4~500 2.5~500 2.5~300 4~300 2.5~300 2.5~300 4~300

b, Construction:
Conductor: Solid or stranded copper
Insulation: Polyvinyl chloride (PVC)
Filler: Polypropylene filament with lapped binding tape
Binder: Binding tape
Inner sheath: Polyvinyl chloride (PVC)
Amour: Galvanized steel wire armored(SWA) or steel tape armored(STA)
Sheath: Polyvinyl chloride (PVC)
c, Nominal Section
Area(mm2) :1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800
d, feature
1). Rated power-frequency voltage Uo/U: 0.6/1KV.
2). Max. permissible continuous operating temperature of conductor: 70ºC
3). Max. shortcircuit temperature of the conductor shall not exceed: (5S maximum duration) 160ºC
4). The ambient temperature under installation should not below 0ºC
5). The bending radius of a cable should not be less than 15 times of the cable diameter.
2 Standard:
IEC60502,and BS6346, VDE, AS/NZS, UL,etc or as customer’s request.
3 The Rated Voltage(kv):
1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 – 26/35
4 Application:
1)These cables are most suitable for direct burial or for installation on trays or ducts, Where there is
a risk of mechanical damage, armoured cables should be used.
2) For laying in ground along route with large difference of level able to bear external mechanical forces.

5 Type and Name:

Type Designation Applications
VV Copper conductor,PVC insulated,PVC sheathed power cable For laying indoors,in tunnel or cable trench,unable
to bear external mechanical forces.Single core
cable is not allowed to laid in magnetic duct.
VLV Aluminum conductor,PVC insulated,PVC sheathed power cable
VY Copper conductor,PVC insulated,PE sheathed power cable
VLY Aluminum conductor,PVC insulated,PE sheathed power cable
VV22 Copper conductor,PVC insulated,steel tape armoured,
PVC sheathed power cable
For laying indoors,in tunnel in cable trench,or direct
in ground,able to bear external mechanical forces.
Single core cable is not allowed to laid in
magnetic duct.
VLV22 Aluminum conductor,PVC insulated,steel tape armoured,
PVC sheathed power cable
VV23 Copper conductor,PVC insulated,steel tape armoured,
PE sheathed power cable
VLV23 Aluminum conductor,PVC insulated,steel tape armoured,
PE sheathed power cable
VV32 Copper conductor,PVC insulated,steel wire armoured,
PVC sheathed power cable
For laying indoors,in tunnel cable trench,well or
direct in ground,able to bear external
mechanical forces and certain pulling force.
VLV32 Aluminum conductor,PVC insulated,steel wire armoured,
PVC sheathed power cable
VV33 Copper conductor,PVC insulated,steel wire armoured,
PE sheathed power cable
VLV33 Aluminum conductor,PVC insulated,steel wire armoured,
PE sheathed power cable

Parameter of 4 core power cable:

Nominal Diameter of Nominal Nominal Nominal Steel Nominal Overall
Cross Conductor Insulation Inner Wire dia. Sheath Diameter
Section (Approx.) thickness Covering thickness (Approx.)
thickness
mm² mm mm mm mm mm mm
4×1.5 1.4 0.7 1 0.8 1.8 14
4×2.5 1.8 0.7 1 0.8 1.8 14.9
4×4 2.3 0.7 1 1.25 1.8 17
4×6 2.8 0.7 1 1.25 1.8 18.2
4×10 3.6 0.7 1 1.25 1.8 20.2
4×16 4.5 0.7 1 1.6 1.8 23
4×25 5.6 0.9 1 1.6 1.8 26.7
4×35 6.7 0.9 1 1.6 1.9 29.5
4×50 8 1 1 2 2.1 34.2
4×70 9.4 1.1 1.2 2 2.2 38.8
4×95 11 1.1 1.2 2 2.3 42.9
4×120 12.4 1.2 1.4 2.5 2.5 48.6
4×150 13.8 1.4 1.4 2.5 2.7 53.2
4×185 15.3 1.6 1.4 2.5 2.8 58.1
4×240 17.5 1.7 1.6 2.5 3.1 64.8
4×300 19.5 1.8 1.6 2.5 3.2 70.4
4×400 22.6 2 1.8 3.15 3.6 81.3

Advantages:
a. Excellent electric and mechanical characteristics
b. Best Resistance chemical corrosion and heat-ageing,environment stress and flame-retardant
c. Simple in structure
d. Convenient to use
e. Light weight,perfect bending properties