11kv Aluminum Swa Cable 3X400mm2

11kv Aluminum Swa Cable 3X400mm2
11kV SWA cable BM25
Construction, Underground
Low and Medium Voltage Cable
DC & AC
XLPE
PVC
Round Wire
Aluminum Wire
ISO, CCC, CE, RoHS, UL, VDE
YJLV22
Yifang
Copper
Yifang Cable
Wooden or Wooden-Steel Drum
3x400mm2
Zhengzhou, China
8544492100

Product Description

3x 400 sq mm power cables free halogen 6.35/11kV (12kV)

Product Description

Reference Standards: IEC60502-2, IEC 60228, IEC60332 -1/2/3, BS6622, BS7835, VDE0276, AS/NZS 1429.1, GB/T 12706, etc.
Rated Voltage: 6/10kV, 6.35/11kV (12kV), 8.7/15kV, 12/20kV, 18/30kV,19/33kV
Core Number: Single Core or Three Core 3x16mm2 power cable (1C or 3C)
Available Dimensions: 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2, 500mm2, 630mm2.
Codes Available: N2XSY, N2XSEY, NA2XSY, NA2XSEY, N2XSRY, NA2XSRY, N2XSEBY, N2XSEYBY, NA2XSEBY, N2XSERY, NA2XSERY, N2XSEYRGbY, NA2XSEYRGbY, N2XS(F)2Y, NA 2XS(F)2Y, N2XS(FL)2Y, N2XSH, N2XSYRY
YJV, YJLV, YJSV, YJLSV, YJV72, YJLV72, YJSV72, YJLSV72, YJV22, YJLV22, YJSV22, YJLSV22, YJV32, YJLV32, YJSV32, YJLSV32
Application: 3x 300 sq mm power cables is used for power networks, underground, outdoors and in cable ducting. 3x 300 sq mm power cables is recommended that the installation instructions indicated by the Local Electric Code, or any equivalent, be followed, so that the safeguarding of persons and the integrity of the product will not be affected during installation.
Construction:
Conductor: Stranded round compacted copper or aluminum conductor (Cu / Al ), copper wire annealed.
Conductor Screen: Semi-conducting material
Insulation: XLPE (Cross-Linked Polyethylene)
Insulation Screen: Semi-conducting material
Metallic Screen: Copper tape screen or copper wire screen (CTS / CWS )
Filler: PP rope
Separator: Binding tape
Bedding: PVC (Polyvinyl Chloride)
Armouring: Single Core: Aluminium Wire Armoured (AWA) Multi-core: Steel Wire Armoured (SWA) or Steel Tape Armoured (STA)
Sheath: PVC (Polyvinyl Chloride), flame retardant PVC, PE, LSOH, HFFR
Colour: Red or Black
Temperature Rating: 0°C to 90°C
Minimum Bending Radius: Single Core: 15 x overall diameter Three Core: 12 x overall diameter (Single Core 12 x overall diameter and 3 core 10 x overall diameter where bands are positioned adjacent to joint or terminations provided that the bending is carefully controlled by the use of a former)