11kv 22kv 33kv Al XLPE Steel Wire Messenger Medium Voltage ABC Cable

11kv 22kv 33kv Al XLPE Steel Wire Messenger Medium Voltage ABC Cable
Medium Voltage ABC Cable
Construction, Overhead, Underground, Industrial, Power Station
Low and Medium Voltage Cable
DC & AC
XLPE
PVC
Round Wire
Aluminum
ISO, CCC, CE
Kema
Aerial Cable
Yifang
3+1
Black or According to Requirement
Sans 1713, IEC 60502-2
Copper Tape
Yifang
Drum
50mm2-630mm2
Zhengzhou, Henan, China
8544601200

Product Description

11KV 22KV 33KV AL XLPE Steel Wire Messenger Medium Voltage ABC Cable

1.Applications

   Aerial Bundle Cable (ABC cable) is a very innovative concept for overhead power distribution as compared to the conventional bare conductor overhead distribution system. It provides higher level of safety and reliability, lower power losses and ultimate system economy by reducing installation,maintenance and operative cost. The cables are designed for aerial power lines and room-entrance wires with AC rated voltage 1kV and below.

2.Standards 

   GB/T12527,1179 ,IEC60502 ,NFC 33-209 ,BS 7870 ,ANSI/ICEA S-76-474  AS/NZS 3560.1 etc.
   *KAIQI POWER can also design and produce for special application requirement.

3.Production Range 

  Rated Voltage U0/U(Um) (kV) : 0.6/1(1.2); 11KV; 25KV; 33KV

No. of cores : 1 , 2 , 3, 4 , 5, 3+1 , 4+1 ,3+2

Nominal cross-section(mm2): 10~240
 

4.Construction
 

• Phase Conductor: Circular compacted stranded H68 aluminium to BS2627.

• Conductor Screen: Extruded semi-conductive layer.

• insulation: XLPE.

• insulation Screen: Extruded semi-conductive layer.

• Metallic Screen(optional): Copper wire screen or copper tape screen.

• Separator: Semi-conductive swellable tape.

• outer Sheath: HDPE or PE

• Support Conductor: Galvanized steel wires.

• Assembly: Three XLPE insulated screened cores are bundled around the galvanized steel wires in a right hand lay.

 

5. Specification

6.35/11KV abc cable

NUMBER OF CORES X NOMINAL CROSS SECTION

PHASE CONDUCTOR

MESSENGER SUSPENSION UNIT

CONTINUOUS CURRENT RATING AT 300C AMBIENT TEMP

STRANDING

NOMINAL SECTIONAL AREA

MAXIMUM CONDUCTOR RESISTANCE

STRANDING

NOMINAL SECTIONAL AREA

BREAKING LOAD

NO.×MM²

NO.×MM

MM²

Ω/KM

NO.×MM

MM²

KN

A

3X50 + 1X25

19/1.78

50

0.641

7/3.0

50

60

116

3X70 + 1X50

19/.14

70

0.443

7/3.15

50

62

210

3X95+ 1X50

19/2.52

95

0.32

7/3.0

50

60

173

3X185+1X120

37/2.52

185

0.164

7/4.67

120

150

259

3X150 +1X50

37/2.25

150

0.206

7/3.15

50

62

365

3X240 +1X50

61/2.25

240

0.125

7/3.15

50

62

500

19/33KV ABC cable

 

 

 

PHASE CONDUCTOR

MESSENGER SUSPENSION UNIT

CONTINUOUS CURRENT RATING AT 300C AMBIENT TEMP

STRANDING

NOMINAL SECTIONAL AREA

MAXIMUM CONDUCTOR RESISTANCE

STRANDING

NOMINAL SECTIONAL AREA

BREAKING LOAD

NO.×MM²

NO.×MM

MM²

Ω/KM

NO.×MM

MM²

KN

  A

3X50 + 1X50

19/1.78

50

0.641

7/3.0

50

60

165

3X150+ 1X50

37/2.25

150

0.206

7/3.0

50

60

315

3X185+1X70

37/2.52

185

0.164

7/3.57

70

91

355

3X70 +1X50

19/2.14

7

0.443

7/3.15

50

62

250

Tags: , ,

Similar Or Related





Please enter your first and last name separated by a space (e.g. Jane Miller)




Success! Thanks for Your Request.
Error! Please Try Again.