10kv Aerial Overhead Compressed ACSR Core Mv ABC Cable

10kv Aerial Overhead Compressed ACSR Core Mv ABC Cable
JKLYJ MV ABC Cable
Jinyuan
Jklvj
ISO, CCC, CE, UL
Aluminium, Copper
Round Wire
PVC
XLPE/PVC
DC & AC
Low and Medium Voltage Cable
Construction, Overhead, Industrial, Power Station
Electricity Distribution
<250°c
40000m2
HUATONG
Drum
IEC60502/60332
China
8544601200

Product Description

10kv 33KV Medium Voltage Aerial Bundle Cable/ ABC Overhead Cable
Characters
Aerial Bunbled Cable (ABC cable) has characters of power-transmitting and strong mechanical. In comparison with bare wire, aerial bundled cable (ABC cable) boasts many advantages, such as : small span in laying, higher safe reliability, better atmosphere aging resistance property. Aerial bundled cable has the priority to be used in urban and rural transmitting construction project.
4. Specifications
1). Aluminum Wire, 1350-H19 for Electrical Purposes. 
2). Aluminum Conductors, Concentric-Lay-Stranded. 
3). Aluminum Conductor, Concentric-Lay-Stranded, Coated Steel Reinforced(ACSR) 
4). Concentric-Lay-Stranded 6201-T81 Conductors 
5). Compressed Round Stranded Aluminum Conductors Using Single Input Wire. 
We can supply this cable according to different recognized standards, such as ASTM B230, B231, B232, B399, ICEA S-76-474, NF , customer’s special specification also can be satisfied.
Overhead ABC Triplex Cable is a new type of aerial cable for power transmitting, It is extensively used in overhead power transmission line, It improves the safety and reliance of electrified wire netting.
SPEC mm2 conductor structure       Approx.    
Phase Neutral(Bare ACSR) insulation insulation Overall Approx. packing
(Compacted AL) Aluminium Steel material Thickness Diameter Weight Meters Per
(No./mm) (No./mm) (No./mm)   (mm) (mm) (kg/km) Drum
1×16+1×16 7/1.72 6/1.72 1/1.72 XLPE 1.2 12.5 121.9 250-4000m
1×25+1×25 7/2.15 6/2.15 1/2.15 1.2 14.9 182.2 250-4000m
1×35+1×35 7/2.54 6/2.54 1/2.54 1.4 17.5 254.7 250-3500m
1×50+1×50 7/2.92 6/2.92 1/2.92 1.4 20.1 333.9 250-3000m
1×70+1×70 19/2.15 12/2.15 17/2.15 1.4 23.6 382.2 250-3000m
1×95+1×95 19/2.54 12/5.24 17/5.24 1.6 27.6 528.2 250-3000m
2×16+1×16 7/1.72 6/1.72 1/1.72 (HDPE) 1.2 14.2 187.6 250-4000m
2×25+1×25 7/2.15 6/2.15 1/2.15 1.2 16.7 273.8 250-3500m
2×35+1×35 7/2.54 6/2.54 1/2.54 1.4 19.7 386.9 250-3500m
2×50+1×50 7/2.92 6/2.92 1/2.92 1.4 22.5 506 250-3000m
2×70+1×70 19/2.15 12/2.15 7/2.15 1.4 26.1 617.2 250-3000m
2×95+1×95 19/2.54 12/5.24 7/5.24 1.6 30.5 850.9 250-3000m
3×16+1×16 7/1.72 6/1.72 1/1.72 1.2 16.3 253.3 250-3500m
3×25+1×25 7/2.15 6/2.15 1/2.15 1.2 19.1 371.9 250-3500m
3×35+1×35 7/2.54 6/2.54 1/2.54 1.4 22.5 519.1 250-3000m
3×50+1×50 7/2.92 6/2.92 1/2.92 1.4 25.7 678.1 250-3000m
3×70+1×70 19/2.15 12/2.15 7/2.15 1.4 29.7 1024.3 250-3000m
2×95+1×95 19/2.54 12/2.54 7/2.54 1.6 34.6 1413.7 250-3000m