10 AWG, Tfn, Thwn or Thhn Overall Shield, Drain Wire PVC Jacket, 600V, 2/C - 37/C
More product about Control Cable10 AWG, Tfn, Thwn or Thhn Overall Shield, Drain Wire PVC Jacket, 600V, 2/C – 37/C
CC-51
Insulated
Stranded
Control Cable
Copper
PVC
XLPE
Round Wire
Control Cable
ISO9001, CE
Yifang
Kvv-Be49
Control Cable
Multicores
UL
Yifang
Wooden Drum
2*10AWG TO 37*10AWG
Zhengzhou, China
8544492100
Product Description
10 AWG, TFN, THWN or THHN Overall Shield, Drain Wire PVC Jacket, 600V, 2/C – 37/C
1
VNTC – TFN, THWN or THHN
Shielded, with Drain Wire
Close Window
Applications
As flame-retardant multi-conductor control, signal or power cables rated 600 volts, 90 Deg. C. in dry locations. 75 Deg. C. in wet locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Also approved for use in Class 1 remote-control and signaling circuits per Article 725 of the NEC. Type TC cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may be installed in air, in ducts or conduits, in tray or trough, are suitable for direct burial.
As flame-retardant multi-conductor control, signal or power cables rated 600 volts, 90 Deg. C. in dry locations. 75 Deg. C. in wet locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Also approved for use in Class 1 remote-control and signaling circuits per Article 725 of the NEC. Type TC cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may be installed in air, in ducts or conduits, in tray or trough, are suitable for direct burial.
Construction
Individual conductors of stranded uncoated copper Type TFN (16AWG). Type THWN or THHN (14-10 AWG), color coded, cabled singles, overall aluminum/polyester foil tape plus tinned Cu drain wire, PVC jacket, surface printed.
Standards
- Listed by UL as Type TC Tray Cable per Article 336 of the NEC.
- Individual conductors UL listed as Type THWN or THHN (14-10 AWG) or Type TFN (16 AWG).
- Overall jacket UL listed as Sunlight Resistant.
- Cables UL listed for Direct Burial.
- Cables pass UL and IEEE-383 ribbon burner tests and ICEA 210.00 BTU/hour test.
Notes
- Drain wire 18 AWG on size 16 AWG conductor constructions, and 16 AWG on all other sizes.
- Class 1 circuits as defined in Article 725.
- Class 1, Division II Hazardous Locations per Article 501.4(B).
- Aerial use permitted with a messenger.
- Standard Color Coding is ICEA Method 1 for NEC applications.
Specification Data
Package and Delivery
Similar Or Related
Tffn/Tfn/Tewn 18 16 14 12 10AWG 2 3cores PVC/Nylon/PVC Unshielded 600V Type Heat Moisture Oil Resist Cable
Read More
Tffn/Tfn/Tewn 18 16 14 12 10AWG 2 3cores PVC/Nylon/PVC Unshielded 600V Type Heat Moisture Oil Resist Cable
Read More
Hutong Types 18 Gauge Building Wiretype Tffn or Mtw or Awm Meets or Exceeds UL Standard 66 Cable
Read More