0.6-1kv PVC Earth Wire and PVC Insulated Earth Wire

0.6-1kv PVC Earth Wire and PVC Insulated Earth Wire
2×1.5+E
Insulated
Solid
Heating, Underground
Copper
PVC
PVC
Round Wire or Flat Wire
Flame Retardant
ISO9001, UL, VDE
Jytop
JYTOP
Packed in 100m Coils
as per popular standards or clients's requirement
Zhengzhou, China
8544492100

Product Description

0.6-1kv pvc earth wire and PVC Insulated Earth Wire

Application:
Designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers.
Standards: BS6004, CENELEC HD21.3
Conductor: Copper conductors to BS EN 60228: 2005 (previously BS6360)
Insulation: PVC (Polyvinyl Chloride) Type TI 1 to BS7655
Insulation Colour: Black, Blue, Green/Yellow, Red, Yellow, White, Violet, Brown, Grey, Orange, Pink
Temperature Rating: 0° C to +70° C
Minimum Bending Radius: 6 X overall diameter

technical date :

Reference No 6242y
Flat-Twin with Bare Earth-continuity Conductor

Size of conductor Nominal thickness
of insulation

mm

Size of earth conductivity
conductor

no./mm

Nominal thickness of sheath

mm

Mean overall dimensions Approx. net weight per km

kg

Nominal
cross-
sectional area

mm2

Number and diameter of wires

mm

Lower limit

mm

Upper limit

mm

1.0 1/1.13 0.6 1/1.13 0.9 4.0*7.2 4.7*8.6 70
1.5 1/1.38 0.7 1/1.13 0.9 4.4*8.2 5.4*9.6 85
2.5 1/1.78 0.8 1/1.13 1.0 5.2*9.4 6.2*11.0 120
4 7/0.85 0.8 1/1.38 1.0 5.6*10.5 7.2*13.0 175
6 7/1.04 0.8 1/1.78 1.1 6.4*12.5 8.0*15.0 240
10 7/1.35 1.0 7/0.85 1.2 7.8*15.5 9.6*19.0 390
16 7/1.70 1.0 7/1.04 1.3 9.0*18 11.0*22.0 560

Notes
1.Conductor of high conductivity copper wires insulated with PVC compound.Sheathed with PVC compound.
2.Core colors: red and black. Sheath colors:grey or white.

300/500V PVC Insulated PVC Sheathed Cables to BS 6004
Reference No 6243y
Three-core (Flat) with Bare
Earth-continuity Conductor

Size of conductor Nominal thickness
of insulation

mm

Size of
earth-
conduct
-ivity
conductor

No/mm

Nominal thickness
of sheath

mm

Mean overall dimensions Approx. net weight per km

kg

Nominal
cross-
sectional area

mm2

Number and diameter of wires

mm

Lower limit

mm

Upper
limit

mm

1.0 1/1.13 0.6 1/1.13 0.9 4.0*9.6 4.7*11.0 92
1.5 1/1.38 0.7 1/1.13 0.9 4.4*10.5 5.4*12.5 115
2.5 1/1.78 0.8 1/1.13 1.0 5.2*12.5 6.2*14.5 170
4 7/0.85 0.8 1/1.38 1.1 5.8*14.5 7.4*18.0 255
6 7/1.04 0.8 1/1.78 1.1 6.4*16.5 8.0*20.0 340
10 7/1.35 1.0 7/0.85 1.2 7.8*21.0 9.6*25.5 550
16 7/1.70 1.0 7/1.04 1.3 9.0*24.5 11.0*29.5 790

Notes
1.Conductor of high conductivity copper wires insulated with PVC compound. Sheathed with PVC compound.
2.Core colors: red, yellow and blue(yellow in centre) Sheath colors: grey or white.

Size of conductor Nominal thickness
of insulation

mm

Size of earth conductivity
conductor

no./mm

Nominal thickness of sheath

mm

Mean overall dimensions Approx. net weight per km

kg

Nominal
cross-
sectional area
mm 2
Number and diameter of wires

mm

Lower limit

mm

Upper limit

mm

2×1.0+E 1/1.13 0.6 1/1.13 0.9 4.0*7.2 4.7*8.6 70
2×1.5+E 1/1.38 0.7 1/1.13 0.9 4.4*8.2 5.4*9.6 85
2×2.5+E 1/1.78 0.8 1/1.13 1.0 5.2*9.4 6.2*11.0 120
2×4+E 7/0.85 0.8 1/1.38 1.0 5.6*10.5 7.2*13.0 175
2×6+E 7/1.04 0.8 1/1.78 1.1 6.4*12.5 8.0*15.0 240
2×10+E 7/1.35 1.0 7/0.85 1.2 7.8*15.5 9.6*19.0 390
2×16+E 7/1.70 1.0 7/1.04 1.3 9.0*18 11.0*22.0 560