0.6 / 1kv 11kv, 33kv PVC / XLPE / PE Insulated Overhead Electric Transmission Aerial

0.6 / 1kv 11kv, 33kv PVC / XLPE / PE Insulated Overhead Electric Transmission Aerial
Aerial Bundled Cable
Jiapu
ISO9001, CE, CCC
Overhead
Round Wire
XLPE
Crosslinking
Aluminum
Overhead
Stranded
Insulated
JP
Wood Drums
ABC cable
China
8544492100

Product Description

0.6 / 1kv 11kv, 33kv PVC / XLPE / PE Insulated Overhead Electric Transmission Aerial 
APPLICATION:
The product is a new type of aerial cable for power transmitting . It is extensively used in overhead power transmission line. It improves the safety and reliance of electrified wire netting . It is primarily used on lighting, outdoor lighting,and temporary service for construction . To be used at voltage of 600V phase-to-phase or less,and the conductor temperatures no exceed 75degred for polyethylene insulated conductors 90degree for crosslinked polyethylene (XLPE) insulated conductors.
CONSTRUCTION:
  Conductors are concentrically stranded,compressed 1350-H19 aluminum. Insulated with either  polyethylene or crosslinked  polyethylene (XLPE). Neutral messengers are concentrically stranded 6201, AAC,or ACSR .
The product is a new type of aerial cable for power transmitting . It is extensively used in overhead power transmission line. It improves the safety and reliance of electrified wire netting . It is primarily used on lighting, outdoor lighting,and temporary service for construction . To be used at voltage of 600V phase-to-phase or less,and the conductor temperatures no exceed 75degree for polyethylene insulated conductors 90degree for crosslinked polyethylene (XLPE) insulated conductors.
Construction
  Conductors are concentrically stranded,compressed 1350-H19 aluminum. Insulated with either  polyethylene or crosslinked  polyethylene (XLPE). Neutral messengers are concentrically stranded 6201, AAC,or ACSR .
Duplex service drop (Bare neutral messenger ACSR)
 
Code word AWG or kcmil Bare neutral messenger Phase conductor  Weight kg/km
ACSR stranding and wires dia. (mm) Rated strength (lbs) AAC Insulation thickness (mm)
Stranding and wires dia. (mm)
Setter 1*6AWG+1*6AWG 1/1.68+6/1.68 1190 1/4.11 1.14 111
Shepherd 1*6AWG+1*6AWG 1/1.68+6/1.68 1190 7/1.56 1.14 113
Eskimo 1*4AWG+1*4AWG 1/2.12+6/2.12 1860 1/5.19 1.14 171
Terrier 1*4AWG+1*4AWG 1/2.12+6/2.12 1860 7/1.96 1.14 173
Chow 1*2AWG+1*2AWG 1/2.67+6/2.67 2850 7/2.47 1.14 266
Bull 1*1/0AWG+1*1/0AWG 1/3.37+6/3.37 4380 19/1.89 1.52

Workshop:

Tags: , ,

Similar Or Related





Please enter your first and last name separated by a space (e.g. Jane Miller)




Success! Thanks for Your Request.
Error! Please Try Again.