Yjv22 Yjv32 XLPE Insulation Steel Wire Armored Power Cable Price List
More product about Aluminum Power CableProduct Description
yjv22 yjv32 Aluminum XLPE insulation Steel Wire Armored Power Cable Price list
Standard:
IEC60502,and BS6346, VDE, AS/NZS, UL,etc or as customer’s request.
The Rated Voltage(kv):
1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 – 26/35
Application:
Power cable are most suitable for direct burial or for installation on trays or ducts, Where there is
a risk of mechanical damage, armoured cables should be used.
TYPE |
NAME |
Main Application |
|
CU core |
AL core |
||
YJV/YJY |
YJLV/YJLY |
XLPE insulated,PVC/PE sheathed power cable |
For laying indoor ,tunnel,canal and underground. |
YJV22/YJV23 |
YJLV22/YJLV23 |
XLPE insulated,steel tape armored, |
For laying indoor ,tunnel,canal and underground. |
YJV32/YJV33 |
YJLV32/YJLV33 |
XLPE insulated,thin steel wire armored, |
For laying in shaft,water underground will large difference of level. |
YJV42/YJV43 |
YJLV42/YJLV43 |
XLPE insulated,thick steel wire armored, |
For laying in water and seabed. |
Number of cores:
1core 2core 3core 3+1core 4core 4+1core 4+2core 5core and so on.
Nominal Section
Area(mm2) :1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Alum Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
mm² | mm | mm | mm | mm | mm | mm |
1×4 | 2.3 | 0.7 | 1 | 0.8 | 1.8 | 10.9 |
1×6 | 2.8 | 0.7 | 1 | 0.8 | 1.8 | 11.4 |
1×10 | 3.6 | 0.7 | 1 | 0.8 | 1.8 | 12.2 |
1×16 | 4.5 | 0.7 | 1 | 0.8 | 1.8 | 13.1 |
1×25 | 5.6 | 0.9 | 1 | 0.8 | 1.8 | 14.6 |
1×35 | 6.7 | 0.9 | 1 | 1.25 | 1.8 | 16.6 |
1×50 | 8 | 1 | 1 | 1.25 | 1.8 | 18.1 |
1×70 | 9.4 | 1.1 | 1 | 1.25 | 1.8 | 19.7 |
1×95 | 11 | 1.1 | 1 | 1.6 | 1.8 | 22 |
1×120 | 12.4 | 1.2 | 1 | 1.6 | 1.8 | 23.6 |
1×150 | 13.8 | 1.4 | 1 | 1.6 | 1.8 | 25.4 |
1×185 | 15.3 | 1.6 | 1 | 1.6 | 1.8 | 27.4 |
1×240 | 17.5 | 1.7 | 1 | 1.6 | 1.9 | 29.9 |
1×300 | 19.5 | 1.8 | 1 | 2 | 2 | 33.1 |
1×400 | 22.6 | 2 | 1.2 | 2 | 2.2 | 37.3 |
1×500 | 25.2 | 2.2 | 1.2 | 2 | 2.3 | 40.5 |
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
mm² | mm | mm | mm | mm | mm | mm |
2×1.5 | 1.4 | 0.7 | 1 | 0.8 | 1.8 | 12.8 |
2×2.5 | 1.8 | 0.7 | 1 | 0.8 | 1.8 | 13.6 |
2×4 | 2.3 | 0.7 | 1 | 0.8 | 1.8 | 14.6 |
2×6 | 2.8 | 0.7 | 1 | 1.25 | 1.8 | 16.5 |
2×10 | 3.6 | 0.7 | 1 | 1.25 | 1.8 | 18.1 |
2×16 | 4.5 | 0.7 | 1 | 1.25 | 1.8 | 19.9 |
2×25 | 5.6 | 0.9 | 1 | 1.6 | 1.8 | 23.6 |
2×35 | 6.7 | 0.9 | 1 | 1.6 | 1.8 | 25.8 |
2×50 | 8 | 1 | 1 | 1.6 | 1.9 | 29 |
2×70 | 9.4 | 1.1 | 1 | 2 | 2 .3 | 3.2 |
2×95 | 11 | 1.1 | 1.2 | 2.1 | 3 | 7.1 |
2×120 | 12.4 | 1.2 | 1.2 | 2 | 2.3 | 40.5 |
2×150 | 13.8 | 1.4 | 1.2 | 2.5 | 2.4 | 45.4 |
2×185 | 15.3 | 1.6 | 1.4 | 2.5 | 20.6 | 49.9 |
2×240 | 17.5 | 1.7 | 1.4 | 2.5 | 20.7 | 55.1 |
2×300 | 19.5 | 1.8 | 1.6 | 2.5 | 20.9 | 60.2 |
2×400 | 22.6 | 2 | 1.6 | 2.5 | 30.1 | 67.7 |
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
mm² | mm | mm | mm | mm | mm | mm |
3×1.5 | 1.4 | 0.7 | 1 | 0.8 | 1.8 | 13.2 |
3×2.5 | 1.8 | 0.7 | 1 | 0.8 | 1.8 | 14.1 |
3×4 | 2.3 | 0.7 | 1 | 0.8 | 1.8 | 15.2 |
3×6 | 2.8 | 0.7 | 1 | 1.25 | 1.8 | 17.1 |
3×10 | 3.6 | 0.7 | 1 | 1.25 | 1.8 | 18.9 |
3×16 | 4.5 | 0.7 | 1 | 1.25 | 1.8 | 20.8 |
3×25 | 5.6 | 0.9 | 1 | 1.6 | 1.8 | 24.7 |
3×35 | 6.7 | 0.9 | 1 | 1.6 | 1.8 | 27.2 |
3×50 | 8 | 1 | 1 | 1.6 | 1.9 | 30.6 |
3×70 | 9.4 | 1.1 | 1 | 2 | 2.1 | 35.2 |
3×95 | 11 | 1.1 | 1.2 | 2 | 2.2 | 39.3 |
3×120 | 12.4 | 1.2 | 1.2 | 2 | 2.3 | 43 |
3×150 | 13.8 | 1.4 | 1.4 | 2.5 | 2.5 | 48.6 |
3×185 | 15.3 | 1.6 | 1.4 | 2.5 | 2.7 | 53 |
3×240 | 17.5 | 1.7 | 1.4 | 2.5 | 2.8 | 58.5 |
3×300 | 19.5 | 1.8 | 1.6 | 2.5 | 3 | 64 |
3×400 | 22.6 | 2 | 1.6 | 3.15 | 3.3 | 73.5 |
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
||
mm² | mm | mm | mm | mm | mm | mm | mm | mm |
3x 16/10 | 4.5 | 3.6 | 0.7 | 0.7 | 1 | 1.6 | 1.8 | 22.7 |
3x 25/16 | 5.6 | 4.5 | 0.9 | 0.7 | 1 | 1.6 | 1.8 | 26.5 |
3x 35/16 | 6.7 | 4.5 | 0.9 | 0.7 | 1 | 1.6 | 1.9 | 29 |
3x 50/25 | 8 | 5.6 | 1 | 0.9 | 1 | 1.6 | 2.1 | 33 |
3x 70/35 | 9.4 | 6.7 | 1.1 | 0.9 | 1.2 | 2 | 2.2 | 38 |
3x 95/50 | 11 | 8 | 1.1 | 1 | 1.2 | 2 | 2.3 | 42.4 |
3×120/70 | 12.4 | 9.4 | 1.2 | 1.1 | 1.2 | 2 | 2.5 | 48 |
3×150/70 | 13.8 | 9.4 | 1.4 | 1.1 | 1.4 | 2.5 | 2.7 | 52 |
3×185/95 | 15.3 | 11 | 1.6 | 1.1 | 1.4 | 2.5 | 2.8 | 57.2 |
3×240/120 | 17.5 | 12.4 | 1.7 | 1.2 | 1.6 | 2.5 | 3.1 | 64 |
3×300/150 | 19.5 | 13.8 | 1.8 | 1.4 | 1.6 | 2.5 | 3.2 | 69.8 |
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
mm² | mm | mm | mm | mm | mm | mm |
4×1.5 | 1.4 | 0.7 | 1 | 0.8 | 1.8 | 14 |
4×2.5 | 1.8 | 0.7 | 1 | 0.8 | 1.8 | 14.9 |
4×4 | 2.3 | 0.7 | 1 | 1.25 | 1.8 | 17 |
4×6 | 2.8 | 0.7 | 1 | 1.25 | 1.8 | 18.2 |
4×10 | 3.6 | 0.7 | 1 | 1.25 | 1.8 | 20.2 |
4×16 | 4.5 | 0.7 | 1 | 1.6 | 1.8 | 23 |
4×25 | 5.6 | 0.9 | 1 | 1.6 | 1.8 | 26.7 |
4×35 | 6.7 | 0.9 | 1 | 1.6 | 1.9 | 29.5 |
4×50 | 8 | 1 | 1 | 2 | 2.1 | 34.2 |
4×70 | 9.4 | 1.1 | 1.2 | 2 | 2.2 | 38.8 |
4×95 | 11 | 1.1 | 1.2 | 2 | 2.3 | 42.9 |
4×120 | 12.4 | 1.2 | 1.4 | 2.5 | 2.5 | 48.6 |
4×150 | 13.8 | 1.4 | 1.4 | 2.5 | 2.7 | 53.2 |
4×185 | 15.3 | 1.6 | 1.4 | 2.5 | 2.8 | 58.1 |
4×240 | 17.5 | 1.7 | 1.6 | 2.5 | 3.1 | 64.8 |
4×300 | 19.5 | 1.8 | 1.6 | 2.5 | 3.2 | 70.4 |
4×400 | 22.6 | 2 | 1.8 | 3.15 | 3.6 | 81.3 |
Features:
1). XLPE insulated power cable not only has excellent electric, mechanical properties, but also has powerful resistance against chemical erosion, heat-aging and environmental stress.
2) .Its structures are simple. The long term operating temperature is +90 degrees. It is convenient to use and can be laid with no restriction of different level.
3). Our XLPE cables can be produced according to our specification which is equivalent to IEC 502-1983, and its some indexes are superior to 502-1983.
4). We can design and manufacture special XLPE cable according to the other standards required by the customers.
5).Application: for laying indoor, tunnel, canal and underground.
Packaging
Packing Details : Packing in wooden drum, iron-wooden drum or as customer’s requirement.
Delivery Details : 15-25 days after place an order.
Similar Or Related