Type Shd-Cgc, Mining Cable, Cu/Epr/CPE, 3/C, 2kv (ICEA S-75-381/NEMA WC-58)

Type Shd-Cgc, Mining Cable, Cu/Epr/CPE, 3/C, 2kv (ICEA S-75-381/NEMA WC-58)

Type Shd-Cgc, Mining Cable, Cu/Epr/CPE, 3/C, 2kv (ICEA S-75-381/NEMA WC-58)

Type SHD-CGC

Insulated

Stranded

Underground

Copper

CPE

Epr

Round Wire

Mine

ISO9001, CCC

Boan

2 Kv

2/0-350 AWG or Mcm

3

DingAn or OEM

Heated Steel-Wooden Drum/Steel Drum

SGS

Jiangsu Yixing, China

8544492100

Product Description

Type SHD-PCG, Mining Cable, Cu/Epr/CPE, 3/C, 2kv (ICEA S-75-381/NEMA WC-58)

Applications
These heavy duty cables are designed for use on longwall shearers, where three shielded power conductors, three unshielded control conductors, and a grounding conductor are required.

Standards

ICEA S-75-381/NEMA WC 58
ASTM B 172
ASTM B 33
CAN/CSA-C22.2 No.96

Construction

Conductors: Stranded annealed tinned copper conductor.
Insulation: Ethylene Propylene Rubber (EPR).
Insulation Shield: Tinned copper/textile braid.

Ground Check Conductor: Tinned copper with a yellow insulation, located in the center of the cable.

Grounding Conductor: Tinned copper conductor, located in the center of the cable.
Jacket: Reinforced extra-heavy-duty Chlorinated Polyethylene (CPE), black.

Options

Other jacket materials such as CSP/PCP/NBR/PVC are available upon request.
Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.

Mechanical and Thermal Properties

Minimum Bending Radius: 6×OD
Maximum Conductor Operating Temperature: +90ºC

Constructon No. of Strands Grounding Conductor Size Control Conductor Size Nominal Insulaton Thickness Nominal Jacket Thickness Nominal Overall Diameter Nominal Weight Ampacity
No. of cores×AWG/kcmil AWG/kcmil AWG/kcmil inch inch inch lbs/kf A
3×2/0 342 5 16 0.08 0.205 2.09 3400 243
3×3/0 418 4 16 0.08 0.205 2.21 3934 279
3×4/0 532 3 16 0.08 0.220 2.36 4860 321
3×350 888 1 16 0.95 0.250 2.81 7400 435