Single Core Copper Conductor Armoured XLPE Insulated PVC Electric Cable Manufacturer
More product about CableProduct Description
Medium Voltage Cable
1. Application
The product is suitable for use in power transmission and distribution lines with rated power frequency voltage 3.6/6kv~26/35kv.
2. Structure:
1. Conductor shape: Aluminum Or Copper
2. Conductor screen: Semi-conductive material
3. Insulation: XLPE
4. Insulation screen: Semi-conductive material
5. Armoured: Steel wire armour or steel tape armour or alumium wire armour
6 Sheath: PVC or MDPE, HDPE, LDPE
3. Operating characteristics
– Rated power-frepuency voltage U0/U: 3.6/6kv~26/35kv.
– Max.admissible operating temperature of the conductor:90ºC.
– Max. short-circurt temperature of conductor shall not exceed 2500C. (5s maximum duration)
– The ambient temperature under installation should not below 0ºC.
– The bending radius of a single-core cable should not less than 20 times of the cable diameter.
The bending radius of a multi-core cable should not less than 15 times of the cable diameter.
4. Table of the voltage, cores and cross-section
8.7/10kV,8.7/15kV Single Core Basic Parameters | ||||||||||||
Nominal Cross Section (mm2 ) |
Thickness of Insulation mm | Thickness of Copper Tape mm | YJV,YJLV | Approx. weight of cable(kg/km) | YJV62,YJLV62 | Approx. weight of cable(kg/km) | ||||||
Thickness of Sheath mm | Overall Diameter of Cable mm | YJV | YJLV | Thickness of PVC Insulation mm |
Thickness of Non-magnetic Steel tape mm | Thickness of Sheath mm | Overall Diameter of Cable mm | YJV62 | YJLV62 | |||
25 | 4.5 | 0.12 | 1.8 | 22.86 | 723 | 574 | 1.2 | 0.2 | 1.8 | 26.06 | 1020 | 871 |
35 | 4.5 | 0.12 | 1.8 | 23.86 | 839 | 632 | 1.2 | 0.2 | 1.8 | 27.06 | 1149 | 942 |
50 | 4.5 | 0.12 | 1.8 | 24.56 | 967 | 688 | 1.2 | 0.2 | 1.9 | 27.96 | 1299 | 1019 |
70 | 4.5 | 0.12 | 1.8 | 26.06 | 1196 | 792 | 1.2 | 0.2 | 1.9 | 29.46 | 1547 | 1143 |
95 | 4.5 | 0.12 | 1.8 | 27.76 | 1478 | 917 | 1.2 | 0.2 | 2 | 31.36 | 1866 | 1305 |
120 | 4.5 | 0.12 | 1.9 | 29.26 | 1745 | 1038 | 1.2 | 0.2 | 2 | 32.66 | 2138 | 1431 |
150 | 4.5 | 0.12 | 1.9 | 30.56 | 2027 | 1154 | 1.2 | 0.2 | 2.1 | 34.16 | 2452 | 1580 |
185 | 4.5 | 0.12 | 2 | 32.46 | 2414 | 1323 | 1.2 | 0.5 | 2.2 | 37.26 | 3208 | 2117 |
240 | 4.5 | 0.12 | 2.1 | 34.86 | 3018 | 1564 | 1.2 | 0.5 | 2.2 | 39.46 | 3848 | 2395 |
300 | 4.5 | 0.12 | 2.1 | 36.76 | 3590 | 1790 | 1.3 | 0.5 | 2.3 | 41.76 | 4507 | 2707 |
400 | 4.5 | 0.12 | 2.3 | 39.76 | 4438 | 2136 | 1.3 | 0.5 | 2.4 | 44.56 | 5402 | 3101 |
500 | 4.5 | 0.12 | 2.3 | 43.56 | 5608 | 2608 | 1.4 | 0.5 | 2.5 | 48.76 | 6712 | 3712 |
630 | 4.5 | 0.12 | 2.5 | 47.06 | 7020 | 3147 | 1.4 | 0.5 | 2.6 | 52.06 | 8182 | 4308 |
8.7/10kV,8.7/15kV 3 cores Basic Parameters | ||||||||||||
Nominal Cross Section (mm2 ) |
Thickness of Insulation mm | Thickness of Copper Tape mm | YJV,YJLV | Approx. weight of cable(kg/km) | YJV22,YJLV22 | Approx. weight of cable(kg/km) | ||||||
Thickness of Sheath mm | Overall Diameter of Cable mm | YJV | YJLV | Thickness of PVC Insulation mm | Thickness of Galvanized Steel tape mm | Thickness of Sheath mm | Overall Diameter of Cable mm | YJV22 | YJLV22 | |||
25 | 4.5 | 0.1 | 2.4 | 45.6 | 2365 | 1916 | 1.4 | 0.5 | 2.5 | 50.6 | 3495 | 3046 |
35 | 4.5 | 0.1 | 2.5 | 47.9 | 2733 | 2111 | 1.4 | 0.5 | 2.6 | 52.9 | 3918 | 3295 |
50 | 4.5 | 0.1 | 2.6 | 49.6 | 3210 | 2367 | 1.5 | 0.5 | 2.7 | 54.8 | 4463 | 3620 |
70 | 4.5 | 0.1 | 2.7 | 53.1 | 3936 | 2719 | 1.5 | 0.5 | 2.8 | 58.3 | 5272 | 4055 |
95 | 4.5 | 0.1 | 2.8 | 57.0 | 4854 | 3165 | 1.6 | 0.5 | 3 | 62.6 | 6346 | 4657 |
120 | 4.5 | 0.1 | 2.9 | 60.0 | 5677 | 3547 | 1.7 | 0.5 | 3.1 | 65.8 | 7278 | 5148 |
150 | 4.5 | 0.1 | 3 | 63.0 | 6613 | 3986 | 1.7 | 0.5 | 3.2 | 68.8 | 8291 | 5664 |
185 | 4.5 | 0.1 | 3.1 | 66.8 | 7785 | 4498 | 1.8 | 0.5 | 3.3 | 72.8 | 9600 | 6313 |
240 | 4.5 | 0.1 | 3.3 | 72.0 | 9749 | 5371 | 1.9 | 0.5 | 3.5 | 78.2 | 11737 | 7360 |
300 | 4.5 | 0.1 | 3.5 | 76.5 | 11580 | 6160 | 2 | 0.8 | 3.7 | 84.1 | 14533 | 9113 |
400 | 4.5 | 0.1 | 3.7 | 82.5 | 14229 | 7297 | 2.1 | 0.8 | 3.9 | 90.3 | 17451 | 10519 |
500 | 4.5 | 0.1 | 3.9 | 91.1 | 18058 | 9020 | 2.2 | 0.8 | 4.1 | 99.1 | 21656 | 12618 |
630 | 4.5 | 0.1 | 4.1 | 98.2 | 22403 | 10737 | 2.4 | 0.8 | 4.4 | 106.8 | 26431 | 14765 |
5. Type and Name
Type | Designation | Applications | |
YJV | Copper conductor,XLPE insulated,PVC sheathed power cable | For laying indoors,in tunnel or cable trench,unable to bear external mechanical forces.Single core cable is not allowed to laid in magnetic duct. | |
YJLV | Aluminum conductor,XLPE insulated,PVC sheathed power cable | ||
YJY | Copper conductor, XLPE insulated,PE sheathed power cable | ||
YJLY | Aluminum conductor, XLPE insulated,PE sheathed power cable | ||
YJV22 | Copper conductor,XLPE insulated,steel tape armoured,PVC sheathed power cable | For laying indoors,in tunnel in cable trench,or direct in ground,able to bear external mechanical forces.Single core cable is not allowed to laid in magnetic duct. | |
YJLV22 | Aluminum conductor,XLPE insulated,steel tape armoured,PVC sheathed power cable | ||
YJV23 | Copper conductor,XLPE insulated,steel tape armoured,PE sheathed power cable | ||
YJLV23 | Aluminum conductor,XLPE insulated,steel tape armoured,PE sheathed power cable | ||
YJV32 | Copper conductor,XLPE insulated,steel wire armoured,PVC sheathed power cable | For laying indoors,in tunnel cable trench,well or direct in ground,able to bear external mechanical forces and certain pulling force. | |
YJLV32 | Aluminum conductor,XLPE insulated,steel wire armoured,PVC sheathed power cable | ||
YJV33 | Copper conductor,XLPE insulated,steel wire armoured,PE sheathed power cable | ||
YJLV33 | Aluminum conductor,XLPE insulated,steel wire armoured,PE sheathed power cable |
6. Our Factory
7. Our Honor
Similar Or Related
10X1.5mm2 Flame Retardant Copper Tape Screen Steel Tape Armored PVC Sheathed Control Cable 0.6/1kV
Read More
0.3/0.5kV 4X4mm2 Copper Wire Braiding PVC Insulation Low Voltage Control Power Cable
Read More
12X2X2.5mm2 Anti-Termite Twisted Pair XLPE Aluminum Foils Polyster Screened Armoured PE sheathed Instrumentation Cable
Read More