Primary Ud Cable, 15 Kv, Al/Tr-XLPE/Neutral/PVC (AEIC CS 8/ICEA S-94-649)

Primary Ud Cable, 15 Kv, Al/Tr-XLPE/Neutral/PVC (AEIC CS 8/ICEA S-94-649)

Primary Ud Cable, 15 Kv, Al/Tr-XLPE/Neutral/PVC (AEIC CS 8/ICEA S-94-649)

Primary UD Cable

Underground

Low and Medium Voltage Cable

DC Cable

XLPE

PVC

Round Wire

Aluminum 1350

ISO, CCC

Primary Ud Cable

Boan

15 Kv

2-1000 AWG or Kcmil

100% or 133%

1/3 or Full

Copper Wire

14/12/10/9 AWG

DingAn or OEM

Heated Steel-Wooden Drum/Steel Drum

SGS

Jiangsu Yixing, China

8544601200

Product Description

Primary UD Cable, 15 KV, AL/TR-XLPE/Neutral/PVC (AEIC CS 8/ICEA S-94-649)
Applications:
Predominantly used for primary underground distribution; Suitable for use in wet or dry locations, direct burial, underground duct, and where exposed to sunlight. To be used at 15, 000 volts or less and at conductor temperatures not to exceed 90° C for normal operation.
Specifications:
Primary UD Cable meets or exceeds the following ASTM specifications:
B-3 Soft Annealed Copper Wire.
B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard or Soft.
B-230 Aluminum, 1350-H19 Wire for Electrical Purposes.
B-231 Aluminum 1350 Conductors, Concentric-Lay-Stranded.
B-609 Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical Purposes.
Primary UD Cable is manufactured to the latest edition of the following specifications, and in case of specification conflicts, in the order listed:
ANSI/ICEA S-94-649
AEIC CS-8
RUS U-1
Construction:
The phase conductor is concentrically stranded, compressed soft copper or 1350-H16/26 aluminum alloy. The cable is composed of the conductor with moisture block in the strands, covered by a semi-conducting cross-linked polyethylene strand shield, a tree-retardant cross-linked polyethylene primary insulation, and a semi-conducting cross-linked polyethylene insulation shield. Conductors are available with either 100% or 133% insulation levels. A concentric neutral of bare copper wires and an insulating polyethylene jacket is applied over the insulation shield. The cable is identified by surface print on the jacket and with the lightning bolt symbol for supply cables indented in the jacket. A semi-conducting polyethylene jacket is available upon request.
Maximum Conductor Normal Operation: – 90O C;
Emergency Overload: – 130O C
Temperatures: Short Circuit – 250 C
Application: Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.

Size AWG or kcmil Number of Strands Nominal OD Over Insulation in 1/3 Neutral Full Neutral
Number of Wires Size AWG Jacket Thickness mil Approximate Outside Diameter in Approximate Net Weight lb/kft Number of Wires Size AWG Jacket Thickness mil Approximate Outside Diameter in Approximate Net Weight lb/kft
Aluminum 100% Insulation Level (175 mil)
2 7 0.67 6 14 80 1.05 467 10 14 80 1.05 520
1 19 0.71 6 14 80 1.08 501 13 14 80 1.08 595
1/0 19 0.75 6 14 80 1.12 541 16 14 80 1.12 675
2/0 19 0.80 7 14 80 1.17 603 13 12 80 1.20 791
3/0 19 0.85 9 14 80 1.22 687 16 12 80 1.25 912
4/0 19 0.90 11 14 80 1.27 784 13 10 80 1.35 1089
250 37 0.96 13 14 80 1.33 874 16 10 80 1.41 1253
350 37 1.06 18 14 80 1.46 1110 16 9 80 1.56 1568
500 37 1.19 16 12 80 1.62 1422 29 10 80 1.66 2069
750 61 1.40 24 12 110 1.89 2059
750 61 1.40 15 10 110 1.93 2065
1000 61 1.54 16 9 110 2.13 2616
Aluminum 133% Insulation Level (220 mil)
2 7 0.76 6 14 80 1.14 528 10 14 80 1.14 582
1 19 0.80 6 14 80 1.18 565 13 14 80 1.18 658
1/0 19 0.84 6 14 80 1.22 607 16 14 80 1.22 741
2/0 19 0.89 7 14 80 1.26 671 13 12 80 1.29 859
3/0 19 0.94 9 14 80 1.31 758 16 12 80 1.34 983
4/0 19 0.99 11 14 80 1.37 858 13 10 80 1.44 1163
250 37 1.05 13 14 80 1.44 975 16 10 80 1.52 1355
350 37 1.15 18 14 80 1.55 1195 16 9 80 1.65 1653
500 37 1.28 16 12 110 1.77 1622 29 10 110 1.81 2272
750 61 1.49 15 10 110 2.02 2175
1000 61 1.64 16 9 110 2.23 2737