Mv Single Core Aluminum or Copper Conductor Power Cable

Mv Single Core Aluminum or Copper Conductor Power Cable
MV single core power cable
Construction, Underground, Industrial, Power Station
Medium Voltage
AC Cable
XLPE
PVC
Round Wire
Copper or Aluminum
ISO, CCC, CE, RoHS
Yjv/Yjlv
Hongda
Steel Wire Armour
Copper/Aluminum
IEC 60502-1
Ten Years
1core
as Your Requirement
Black
Yes
Yes
Hongda
Wooden Drum
single core power cable
China, Henan
8544492100

Product Description

0.6/1kv 3x185mm2 Copper XLPE/PVC SWA Power Cable


Application:

It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable.
Construction:
Conductor: Copper (or Aluminium)
Insulation: XLPE
Filler: Non-hygroscopic Polypropylene(PP)
Binder Tape: Non-woven fabric
Inner Covering: PVC
Metallic Armour: Galvanized Steel Wire Armour(SWA)
Non-magnetic Steel Wire Armour(only for single core)
Aluminium Wire Armoured(AWA, only for single core)
Outer Sheath: PVC (or PE)
Standards:
The products are mainly complying with IEC 60502 standard, also can be produced according to OEM requirements and other standards, such as BS standard, DIN standard, ASTM standard, etc.
Voltage grade is up to 35kv, cross-section area can be up to 400 sqmm (copper or alumimum conductor). Conductor long-time operating temperature is 90° C. In short circuit, conductor highest temperature should be not more than 250° C

Using features:

1. Rated voltage: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV.
2. No. Of core: Single-core, Three-core.
3. The highest allowed operating temperature of conductor for long-term working is 90° C. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250° C.
4. D. C Resistance of the conductor complies with the stipulations of GB/T3956-1997.
5. The environment temperature should be no lower than 0° C when lay. Otherwise it should be preheated.
6. The cable is laid without horizontal drop limit. The Min. Bending radius of three-core cable should be no smaller than 12 times of cable outer diameter.
7. Working Frequency Voltage Test: .
For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture.
For cable with Uo of 3.6Kv~18kV: 3.5Uo/5min without puncture.
For cable with Uo of 21kV and 26 kV: 2.5Uo/30min without puncture.

Chinese Type Description Application
Cu Al
YJV YJLV Cu conductor(Al conductor)XLPE insulated PVC sheathed power cable Laying indoors, in tunnel, fixed on the bracket, pipe and buried in the soil, the cable can not bear external mechanical forces.
YJY YJLY Cu conductor(Al conductor)XLPE insulated PE sheathed power cable
YJV22 YJLV22 Cu conductor(Al conductor)XLPE insulated double of steel-tape armored PVC sheathed power cable For laying indoors, in tunnel, cable trench, or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force.
YJV23 YJLV23 Cu conductor(Al conductor)XLPE insulated double of steel-tape armored PE sheathed power cable
YJV62 YJLV62 Cu conductor(Al conductor)XLPE insulated double of aluminium-tape armored PVC sheathed power cable
YJV32 YJLV32 Cu conductor(Al conductor)XLPE insulated steel-wire armored PVC sheathed power cable For laying indoors, in tunnel, cable trench, well or direct in ground, able to bear external mechanical forces and certain pulling force
YJV33 YJLV33 Cu conductor(Al conductor)XLPE insulated steel-wire armored PE sheathed power cable
YJV72 YJLV72 Cu conductor(Al conductor)XLPE insulated aluminium-wire armored PE sheathed power cable

Specification of product.

1. 1 core: 1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2, 500mm2, 630mm2.

2. 2 core: 1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2.

3. 3 core: 1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2.

4. 4 core: 1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2.

5. 5 core: 1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2.

6. 3+1 core: 2.5+1.5mm2, 4+2.5mm2, 6+4mm2, 10+6mm2, 16+10mm2, 25+16mm2, 35+16mm2, 50+25mm2, 70+35mm2, 95+50mm2, 120+70mm2, 150+70mm2, 185+95mm2, 240+120mm2, 300+150mm2, 400+185mm2

7. 3+2 core: 2.5+1.5mm2, 4+2.5mm2, 6+4mm2, 10+6mm2, 16+10mm2, 25+16mm2, 35+16mm2, 50+25mm2, 70+35mm2, 95+50mm2, 120+70mm2, 150+70mm2, 185+95mm2, 240+120mm2, 300+150mm2, 400+185mm2

8. 4+1 core: 2.5+1.5mm2, 4+2.5mm2, 6+4mm2, 10+6mm2, 16+10mm2, 25+16mm2, 35+16mm2, 50+25mm2, 70+35mm2, 95+50mm2, 120+70mm2, 150+70mm2, 185+95mm2, 240+120mm2, 300+150mm2, 400+185mm2

Packaging&Delivery.

Packaging Details:Wooden drums,steel wooden drums or as your requirement
Delivery Time:Normally within 7 days(detailly depend on the order quantity)

Contact us
Looking forward to cooperation with you.If you have any question or need our certification and sample.Pls contact me freely.You can talk with me by Email or chat software. Tel:+86 18639114351

Tags: , ,