Mv-90, Power Cable, 15 Kv, 1/C, Cu/XLPE/Cws/PVC (ICEA S-93-639/NEMA WC74/UL 1072)

Mv-90, Power Cable, 15 Kv, 1/C, Cu/XLPE/Cws/PVC (ICEA S-93-639/NEMA WC74/UL 1072)

Mv-90, Power Cable, 15 Kv, 1/C, Cu/XLPE/Cws/PVC (ICEA S-93-639/NEMA WC74/UL 1072)

MV-90

Construction, Underground, Industrial, Power Station

Low and Medium Voltage Cable

DC Cable

XLPE

PVC

Round Wire

Bare Copper Wire

ISO, CCC

Mv-90

Boan

15 Kv

1

2 AWG-1000 Mcm

B

100% or 133%

DingAn

Heated Steel-Wooden Drum/Steel Drum

SGS

Jiangsu Yixing, China

8544601200

Product Description

MV-90, Power Cable, 15 KV, 1/C, Cu/XLPE/CWS/PVC (ICEA S-93-639/NEMA WC74/UL 1072)

Features
UL Listed as MV-90. Rated as Sunlight Resistance. Oil Resistance I jacket. True Triple extrusion system and
closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.

Application

Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities. May be used in wet or dry
locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.

Standards

UL 1072: Medium Voltage Power Cables.
ICEA S-93-639/NEMA WC74: 5 kV – 46 kV Shielded Power Cables.
ICEA S-97-682: Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.
AEIC CS8: Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.

Specifications

Maximum operating voltage: 5 kV to 35 kV 100% and 133% IL
Maximum conductor operation temperatures: Wet and dry locations: Normal: 90 °C, Emergency: 130 °C, Short Circuit: 250 °C

Engineering Information
1. Conductor: Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400. On request, strand filled or compressed strand. Sizes: 2 AWG up to 1000 kcmil.
2. Conductor Shield: Semi conducting cross-linked polyethylene (XLPE).
3. Insulation: Thermoset crosslinked polyethylene (XLPE). On request, TR-XLPE.
4. Insulation Shield: Semi conducting cross-linked polyethylene (XLPE).
5. Metallic Shield: Solid soft annealed uncoated copper wires per ASTM B3, helically applied and uniformly spaced.
6. Binder Tape: A suitable tape, as required.
7. Jacket: Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.

100% Insulation Levels (175 mil) 133% Insulation Levels (220 mil)
Size Number of Strands Conductor Nominal Diameter Over Insulation Jacket Thickness Approximate Outside Diameter Approximate Net Weight Diameter Over Insulation Jacket Thickness Approximate Outside Diameter Approximate Net Weight
Copper Aluminum Copper Aluminum
AWG of kcmil in in mil in lb/kft in mil in lb/kft
2 7 0.27 0.65 80 0.94 524 382 0.74 80 1.03 583 441
1 19 0.3 0.68 80 0.97 591 412 0.77 80 1.06 652 472
1/0 19 0.34 0.72 80 1.01 677 450 0.81 80 1.10 740 513
2/0 19 0.38 0.76 80 1.05 781 495 0.85 80 1.14 847 561
3/0 19 0.42 0.81 80 1.10 912 551 0.90 80 1.19 980 619
4/0 19 0.48 0.86 80 1.15 1073 618 0.95 80 1.24 1144 689
250 37 0.52 0.92 80 1.2 1226 689 1.01 80 1.32 1323 785
300 37 0.57 0.97 80 1.25 1405 760 1.06 80 1.37 1505 861
350 37 0.62 1.01 80 1.32 1606 852 1.10 80 1.41 1687 933
400 37 0.66 1.05 80 1.37 1782 922 1.14 80 1.46 1865 1005
500 37 0.74 1.13 80 1.44 2130 1055 1.22 80 1.53 2218 1142
600 61 0.81 1.22 80 1.53 2491 1201 1.31 80 1.62 2584 1293
750 61 0.91 1.31 80 1.62 3003 1390 1.40 110 1.78 3205 1592
1000 61 1.06 1.47 110 1.84 3960 1810 1.56 110 1.96 4118 1968