Instrument Cable 0.75mm2 1.0mm2 1.5mm2 2.5mm2

Instrument Cable 0.75mm2 1.0mm2 1.5mm2 2.5mm2

Instrument Cable 0.75mm2 1.0mm2 1.5mm2 2.5mm2

Construction, Underground, Industrial, Power Station, Telecommunication

Low and Medium Voltage Cable

AC Cable

XLPE

PVC

Round Wire

Bare Copper Wire

ISO, CCC

YJV

OEM

OEM

in Drum or in Coil

Henan

8544492100

Product Description

Areas of Use

Instrument cable is suitable for instruments and other electrical equipment in the signal transmission and control circuit.

Usedfor communicationandinstrumentationpurposes inindustries likeoil exploration, cement,paper, steel,powergenerationas well as inintrinsically safe
systems inhazardous areas likepetrochemicalplants andthermalpowerplants tomonitor measuringequipment inprocess automationapplications. HFFR
types areless flammableincaseof fire, mostly selfextinguishing,havelow smokedensityandtheydonotemitpoisonous andcorrosivegassesduringfire.
Armouredtypesprovide mechanical strengthandprotects thecablecoreagainstouter mechanical effects.
CableConstruction
Conductor StrandedAnnealedCopper (IEC/EN 60228,Class2)
Insulation XLPE(EN 50290-2-29)
CoreColors Pair: Black / White, NumberedTriples: Balck / White/ Red, Numbered Quad: Black /
White/ Red/ Blue, Numbered
Separator PETFoil
IndividualScreen Al-PETFoil (with0.60 mm TinnedCopper DrainWire)
Lay-up Shieldedpairs / triples /quads arestrandedinlayers
Separator PETFoil
OverallScreen Al-PETFoil (with7x0.30 mm TinnedCopper DrainWire)
InnerSheath HalogenFreeFlame RetardantCompound(HFFR/LSZH/LSOH/FRNC) (EN 50290-2-27)
Armour Round GalvanizedSteel Wire(Min. Diameter0.90 mm ±0.02 mm)
OuterSheath HalogenFreeFlame RetardantCompound(HFFR /LSZH/LSOH/FRNC) (EN 50290-2-27),
RAL9005- Black, RAL5015- Blue(other colorsuponrequest)
ReferenceStandards BS/EN 50288-7
TechnicalProperties
OperatingVoltage 500V*
TestVoltage Core-Core:1000V;Core-Screen:1000V
Conductor Resistance 0.50 mm²- 36 Ω/km;0.75 mm²- 24.5 Ω/km;1.00 mm²- 18.1 Ω/km;1.30 mm²- 14.2 Ω/km;1.50 mm²- 12.1 Ω/km;2.50 mm²- 7.41 Ω/km
Insulation Resistance >5000 M.Ωxkm
Capacitance Unbalance(800 Hz) 500pF/500m
Capacitance(@800Hz) 115nF/km (Capacitancevalues may increaseby20%upto4pairs)
L/R Ratio 0.50 mm²..1.00 mm²- 25µH/Ω;1.30 mm²..1.50 mm²- 40µH/Ω;2.50 mm²- 60
µH/Ω
Temperature Range Fixed: -40°C……..+90°C,Flexible: -5°C……..+50°C
Flame Retardancy IEC/EN 60332-1, IEC/EN 60332-3-24(CATC)
Smoke Density IEC/EN 61034-1
Amountof HalogenAcidGas IEC/EN 60754-1
CorrosiveGases Measurement IEC/EN 60754-2
Oil Resistance IEC/EN 60811-404,ASTM No2oil70°C4hoursMin.Bending Radius (Fixed) 12xCable Diameter
Description

CONDUCTOR Annealed copper, sizes: 0.5mm² and 0.75mm² mulitistranded(Class 5), 0.5 mm², 1.0 mm² solid(Class 1), 1.5mm² or 2.5mm², multistranded(Class 2) to BS6360
INSULATION PE (Polyethylene) type 03 to BS6234
PAIRING Two insulated conductors uniformly twisted together with a lay not exceeding 100mm
COLOUR CODE See technical information
BINDER TAPE PETP transparent tape
COLLECTIVE SCREEN Aluminium/polyester tape is applied over the laid up pairs metallic side down in contact with tinned copper drain wire, 0.5mm²
OUTER SHEATH PVC Sheath, type TM 1 or type 6 to BS 6746
SHEATH COLOUR Black or blue 

Technical Data

NO.OF PAIRS NO.AND DIA. OF WIRES NOMINAL CONDUCTOR CROSS-SECTIONAL AREA NOMINAL RADIAL THICKNESS OF INSULATION NOMINAL THICKNESS OF SHEATH NOMINAL DIA. OF CABLE APPROX.WEIGHT

 

NO./MM MM2 MM MM MM KG/KM
1 1/0.8 0.5 0.5 0.8 5.5 35
2 1/0.8 0.5 0.5 0.8 6.8 55
5 1/0.8 0.5 0.5 1.1 10.9 125
10 1/0.8 0.5 0.5 1.2 14.4 215
15 1/0.8 0.5 0.5 1.2 16.5 300
20 1/0.8 0.5 0.5 1.3 18.8 385
30 1/0.8 0.5 0.5 1.3 22.3 545
50 1/0.8 0.5 0.5 1.5 28.5 875
1 16/0.2 0.5 0.6 0.8 6.2 60
2 16/0.2 0.5 0.6 0.8 7.6 80
5 16/0.2 0.5 0.6 1.1 12.4 210
10 16/0.2 0.5 0.6 1.2 16.5 340
15 16/0.2 0.5 0.6 1.3 19.2 440
20 16/0.2 0.5 0.6 1.3 21.7 570
30 16/0.2 0.5 0.6 1.5 26.4 780
50 16/0.2 0.5 0.6 1.7 33.4 1130
1 24/0.2 0.75 0.6 0.8 6.7 75
2 24/0.2 0.75 0.6 0.9 8.4 100
5 24/0.2 0.75 0.6 1.2 13.8 250
10 24/0.2 0.75 0.6 1.3 18.4 450
15 24/0.2 0.75 0.6 1.5 21.1 600
20 24/0.2 0.75 0.6 1.5 24.4 920
30 24/0.2 0.75 0.6 1.7 29.5 980
50 24/0.2 0.75 0.6 2 37.6 1690
1 1/1.13 1 0.6 0.8 6.6 85
2 1/1.13 1 0.6 0.8 8 115
5 1/1.13 1 0.6 1.2 13.5 290
10 1/1.13 1 0.6 1.2 17.7 500
15 1/1.13 1 0.6 1.3 20.6 670
20 1/1.13 1 0.6 1.5 23.8 950
30 1/1.13 1 0.6 1.5 28.4 1030
50 1/1.13 1 0.6 2 36.6 1750
1 7/0.53 1.5 0.6 0.8 7.5 100
2 7/0.53 1.5 0.6 0.9 9.3 150
5 7/0.53 1.5 0.6 1.2 15.6 360
10 7/0.53 1.5 0.6 1.3 20.9 690
15 7/0.53 1.5 0.6 1.5 24.6 880
20 7/0.53 1.5 0.6 1.5 27.8 1230
30 7/0.53 1.5 0.6 1.7 33.7 1560
50 7/0.53 1.5 0.6 2 43 2400

 

Application
Mainly used in indoor installation, also installed in a humid environment. In the industrial production process to complete the pass.
 

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.