Application:
It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable.
Construction:
Conductor: Copper (or Aluminium)
Insulation: XLPE
Filler: Non-hygroscopic Polypropylene(PP)
Binder Tape: Non-woven fabric
Inner Covering: PVC
Metallic Armour: Galvanized Steel Wire Armour(SWA)
Non-magnetic Steel Wire Armour(only for single core)
Aluminium Wire Armoured(AWA, only for single core)
Outer Sheath: PVC (or PE)
Standards:
The products are mainly complying with IEC 60502 standard, also can be produced according to OEM requirements and other standards, such as BS standard, DIN standard, ASTM standard, etc.
Voltage grade is up to 35kv, cross-section area can be up to 400 sqmm (copper or alumimum conductor). Conductor long-time operating temperature is 90°C. In short circuit, conductor highest temperature should be not more than 250°C
Using features:
1. Rated voltage: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV.
2. No. of core: Single-core, Three-core.
3. The highest allowed operating temperature of conductor for long-term working is 90°C. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250°C.
4. D.C Resistance of the conductor complies with the stipulations of GB/T3956-1997.
5. The environment temperature should be no lower than 0°C when lay. Otherwise it should be preheated.
6. The cable is laid without horizontal drop limit. The Min. Bending radius of three-core cable should be no smaller than 12 times of cable outer diameter.
7. Working Frequency Voltage Test:.
For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture.
For cable with Uo of 3.6Kv~18kV: 3.5Uo/5min without puncture.
For cable with Uo of 21kV and 26 kV: 2.5Uo/30min without puncture.
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.
Type |
Description |
Number of cores |
Nominal cross section of conductor |
YJV32 |
CU/XLPE/SWA/PVC Power Cable |
1, 2, 3, 4, 3+1, 5, 4+1, 3+2 |
1.5~1000mm2 |
YJLV32 |
AL/XLPE/SWA/PVC Power Cable |
||
YJV72 |
CU/XLPE/Non-magnetic SWA or AWA/PVC Power Cable |
1 |
1.5~1000mm2 |
YJLV72 |
AL/XLPE/Non-magnetic SWA or AWA/PVC Power Cable |
||
YJV33 |
CU/XLPE/SWA/PE Power Cable |
1, 2, 3, 4, 3+1, 5, 4+1, 3+2 |
1.5~1000mm2 |
YJLV33 |
AL/XLPE/SWA/PE Power Cable |
||
Z-YJV32 |
CU/XLPE/SWA Flame-retardant Power Cable |
1, 2, 3, 4, 3+1, 5, 4+1, 3+2 |
1.5~1000mm2 |
Z-YJLV32 |
AL/XLPE/SWA Flame-retardant Power Cable |
||
WDZ-YJY33 |
CU/XLPE/SWA Low Smoke Halogen Free or Zero Halogen (LSHF or LSZH) Flame-retardant Power Cable |
1, 2, 3, 4, 3+1, 5, 4+1, 3+2 |
1.5~1000mm2 |
WDZ-YJLY33 |
AL/XLPE/SWA Low Smoke Halogen Free or Zero Halogen (LSHF or LSZH) Flame-retardant Power Cable |
||
N-YJV32 |
CU/XLPE/SWA Fire-resistant Power Cable |
1, 2, 3, 4, 3+1, 5, 4+1, 3+2 |
1.5~1000mm2 |
Type |
Name |
Application |
|
Cu conducto |
Al Conductor |
||
YJV |
YJLV |
XLPE insulated, PVC or PE sheathed power cable |
For laying indoor, tunnel, channel and underground. Unable to bear external mechanical force during laid. |
YJY |
YJLV |
||
YJV22 |
YJLV22 |
XLPE insulated, steel tape armoured, PVC or PE sheathed power cable |
For laying indoor, tunnel, channel and underground. Able to bear external mechanical force, but unable to bear large pulling force. |
YJV23 |
YJLY23 |
||
YJV32 |
YJLV32 |
XLPE insulated, fine steel wire armoured, PVC or PE sheathed power cable |
For laying in shaft with large difference of level. Able to bear external mechanical force ,and moderate pulling force. |
YJV42 |
YJLV42 |
XLPE insulated, thick steel armoured, PVC or PE sheathed power cable |
For laying in shaft with large difference of level. Able to bear external mechanical force ,and moderate pulling force. |
======================================================
*Company Description*
======================================================
Zhengzhou Jinshui Industry & Commerce Co.Ltd is located in the national class Zhengzhou high and new technology industries zone in Zhengzhou ,Henan province. We have owned a number of exclusive essential manufacture technologies and has pass ISO 9001 Quality Management Systerm ,ISO 14001 Environmental Management Systerm ,OHSAS18001 occupational Heath Management Systerm ,ISO 10012 Measurement Management Systerm and others from China and abroad.
We have been engaged in producing electric cable and wire for nearly 20 years, and we are also 12 year gold supplier. And we are confident that we can offer the best service and quality for you .
Our product range is as following:
*Bare conductors(AAC, AAAC, ACSR, Galvanized steel wire)
*Aerial Bounded Cable (Duplex, Triplex,Quadruplex)
* PVC insulated wire (Rated voltage to 450/750V)
*THHN/THWN wire
*PVC insulated Power Cable
*XLPE insulated Power Cable
*Rubber sheathed Cable
*Control Cable
*Welding Cable
*Cable Accessories
We take part in many fairs and exhibitions in China and abroad . Our aim is to be our customer’s factory in Zhengzhou ,China .
We are here to help you placing orders of cost-effective electric cable and keep tracking your products and shipment.
===========================================================
* Our Factory *
==========================================================
1,Professional production lines, experienced worker, ensure the production of every thing is fine and accurate.
2,We choose excellent raw materials carefully to ensure the quality and meet the need of customers.
3,Mechanical testing of Cables is done to determine the quality and mechanical characteristics before delivery.
- Next: Lvtc (low voltage twisted cable) ABC Cable 3X70 50 ABC Lines