Hv ABC Cable, Aerial Bundled Cable, Al/XLPE/HDPE+AAAC, 3/C+1/C, 12.7/22 Kv (AS/NZS 3599.2)
Product Description
Non Metallic Screened HV ABC
Conductors
Phase conductors are stranded circular compacted aluminium alloy 1350 to H68 condition. The standard catenary is bare stranded circular compacted aluminium alloy 1120 conductor. For special applications, such as high wind locations, aluminium-clad steel-reinforced catenaries are available.
Conductor Screen, Insulation and Insulation Screen
Semiconductive conductor screen, XLPE insulation and semiconductive insulation screen are triple extruded. The insulation screen is hand strippable without preheating and complies with strippability and adhesion tests given in AS/NZS 3599.2. Figures and words "1 ONE," "2 TWO" and "3 THREE" are marked on the insulation screen to identify the three phase cores.
We has developed a special Non Metallic Screened HV ABC with far greater resistance to damage from abrasion during installation or due to brushing with trees. This special cable has a semiconductive HDPE layer over the hand-strippable insulation screen, providing less risk of damage during installation and service.
The cable bundle
The three single core cables are bundled around the aluminium alloy 1120 catenary in a right hand lay. Operating temperatures
(a) Normal operation 90°C
(b) Emergency operation 105°C
(c) Short circuit operation 250°C (5s max)
AS/NZS-3599.2 | ||||||||
HV XLPE Insulated Non-metallic Screend ABC 6.35/11 KV & 12.7/22 KV (Cross-linked Screen with Semi-conductive HDPE) | ||||||||
Units | 12.7/22 KV | |||||||
Nominal Conductor Area | mm2 | 35 | 50 | 70 | 95 | 120 | 150 | 185 |
Average Insulation Thickness | mm | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 |
Average Insulation Screen Thickness | mm | 1.8 | 1.8 | 1.8 | 1.8 | 1.8 | 1.8 | 1.8 |
AAAC/1120 Support Conductor Size | no/mm | 7/4.75 | 7/4.75 | 7/4.75 | 7/4.75 | 19/3.50 | 19/3.50 | 19/3.50 |
Nominal Overall Diameter | mm | 60.6 | 62.9 | 66.1 | 69.5 | 75.5 | 78.3 | 81.3 |
Approx. Mass | kg/km | 1730 | 1910 | 2200 | 2530 | 3000 | 3320 | 3690 |
DC Resistance at 20°C | Ω/km | 0.868 | 0.641 | 0.443 | 0.320 | 0.253 | 0.206 | 0.164 |
AAAC/1120 Support Conductors | ||||||||
Units | ||||||||
Stranding & Nom. Wire Dia. | no/mm | 7/4.75 | 19/3.50 | |||||
Nominal Overall Diameter | mm | 14.3 | 17.5 | |||||
DC Resistance at 20°C | Ω/km | 0.239 | 0.163 | |||||
Minimum Breaking Load | kN | 27.1 | 41.7 |
- Next: Lihh, Data Cable, 300/500 V, Flexible Cu/Hffr/Hffr (DIN VDE 0812)
- Previous: Type Shd-Cgc, Mining Cable, Cu/Epr/CPE, 3/C, 2kv (ICEA S-75-381/NEMA WC-58)
Contact us
Similar Or Related
-
XLPE Insulated Aerial Service Drop Cable Conductor #3AWG Duplex ICEA S-66-524 NEMA WC7
-
WIRE QUADRUPLEX 2/0AWG Thoroughbred 6201 ALLOY NEUTRAL MESSENGER
-
WIRE QUADRUPLEX 6AWG French COACH 6201 ALLOY NEUTRAL MESSENGER
-
HDPE Insulated ACSR Conductor 4/0AWG 15kV Tree Wire for Distribution Lines
-
XLPE Insulated Aerial Service Drop Cable Conductor #3AWG Duplex ICEA S-66-524 NEMA WC7
-
Hv ABC Cable, Aerial Bundled Cable, Al/XLPE/HDPE+AAAC, 3/C+1/C, 12.7/22 Kv (AS/NZS 3599.2)