Acyy / Acyy-F 0.6/1kv Aluminium Conductor PVC Insulated and Sheathed Cable

Acyy / Acyy-F 0.6/1kv Aluminium Conductor PVC Insulated and Sheathed Cable
cablu acyy
Hongda Cable
Acyy / Acyy-F
ISO, CCC
Aluminum Conductor
Round Wire
PVC
PVC
DC Cable
Low and Medium Voltage Cable
Construction, Underground, Industrial, Power Station
PVC Insulated
PVC (Polyvinyl Chloride), Fire Resistant
Hongda
500m Per Drum
1.5 – 300 sq. mm
China
8544492100

Product Description

ACYY / ACYY-F – Low voltage power cable 0.6/1 kV

1. Cable construction
Conductor: aluminum (class 1 or 2), monowire (re), multiwire (rm).
Insulation: PVC
Filling.
Outer sheath: PVC, black or grey.

Application
Power supply to power stations. The cables can be installed in open or confined areas, underground (in pipes), in sewers, in concrete, in places where no mechanical damage is expected.

ACYY / ACYY-F  low voltage power cable 0.6./1 kV – Technical data and tests

Conductor type : monowire (re), multiwire (rm)
Rated voltage Uo/U :  0.6/1 kV
Test voltage : 4 kV AC or 12 kV DC, 5 min
Min. temperature of cable : installation :   -5º C
Max. allowed operating temperature : 70º C
Max. short-circuit temperature : 160º C
Min. bending radius : 15 x cable diameter – single-core cable
12 x cable diameter – multicore cable
Max. tensile strain during installation : max 50 N/mm²
Color coding : 1 conductor-blue or yellow-green;
2 conductors – blue,brown;
   – yellow-green,black for sect > 10 mm²;
3 conductors – brown,black,grey;      
   – yellow-green, blue,brown;
4 conductors – blue, brown, black,grey;      
   – yellow-green, brown,black,grey;
 5 conductors – blue, brown, black, grey, black;    
    – yellow-green, blue, brown, black,grey;
More than 5 conductors: – numbered black conductors;
   – yellow-green and numbered conductors.
Standards:
Cable                : IEC 60502-1.
Conductors        : IEC 60228.
Insulation          : IEC 60502-1.
Flame retardancy:
ACYY    : EN 50265-2-1 (IEC 60332-1) – flames on a single vertical cable. 
ACYY-F : EN 50266-2-4 (IEC 60332-3-25 Cat. C) – flames on a bundle of cables.

ACYY / ACYY-F  low voltage power cable 0.6./1 kV – Applications
ACYY / ACYY-F is a cable for power supply to power stations. This cable can be installed in open or confined areas, underground (in pipes), in sewers, in concrete, in places where no mechanical damage is expected.
 
ACYY / ACYY-F  low voltage power cable 0.6./1 kV – Other standards
British             : AL/PVC/PVC.
German           : NAYY.
Austrian           : E-AYY.
Russian            : АВВГ.
Central Europe : PP 00-A.
Turkish            : YAVV-R.

2. Construction data of power cables / CYABY-F

Cable Size Type of Conductor Radial Thickness of Insulation Radial Thickness of Sheath Outer Diameter Approx. Cable Weight
    mm mm mm kg/km
1×4 re 1 1.4 7.9 66
1×6 re 1 1.4 8.4 78
1×10 re 1 1.4 9.2 98
1×16 re 1 1.4 10.9 126
1×25 re 1.2 1.4 12.6 188
1×35 re 1.2 1.4 13.8 230
1×50 rm 1.4 1.4 15.6 297
1×70 rm 1.4 1.5 17.3 388
1×95 rm 1.6 1.6 19.7 58
1×120 rm 1.6 1.6 21 605
1×150 rm 1.8 1.7. 23.1 743
1×185 rm 2 1.7. 25.5 922
1×240 rm 2.2 1.9 30.2 1176
1×300 rm 2.4 2 31.3 1431
2×4 re 1 1.8 12.3 207
2×6 re 1 1.8 13.5 255
2×10 re 1 1.8 15.1 326
2×16 re 1 1.8 18.8 430
2×25 re 1.2 1.8 22.2 678
2×35 re 1.2 1.8 24.6 841
3×4 re 1 1.8 13 233
3×6 re 1 1.8 14.3 287
3×10 re 1 1.8 16 371
3×16 re 1 1.8 20 471
3×25 re 1.2 1.8 23.6 773
3×25+16 re/re 1.2/1.0 1.8 25 840
3×35 re 1.2 1.8 26.2 961
3×35+16 re/re 1.2/1.0 1.8 27.1 978
3×50 sm 1.4 1.8 25 814
3×50+25 sm/rm 1.4/1.2 1.9 29 1025
3×70 sm 1.4 1.9 28 1170
3×70+35 sm/rm 1.4/1.2 2 35 1354
3×95 sm 1.6 2.1 30 1530
3×95+50 sm/sm 1.6/1.4 2.2 41 1844
3×120 sm 1.6 2 33 1879
3×120+70 sm/sm 1.6/1.4 2.3 45 2187
3×150 sm 1.8 2.2 36.9 2327
3×150+70 sm/sm 1.8/1.4 2.4 49 2648
3×185 sm 2 2.3 40.9 2892
3×185+95 sm/sm 2.0/1.6 2.6 53 3343
3×240 sm 2.2 2.5 47.5 4380
3×240+120 sm/sm 2.2/1.6 2.8 60 4258
4×4 re 1 1.8 14.1 276
4×6 re 1 1.8 15.5 342
4×10 re 1 1.8 17.5 445
4×16 re 1 1.8 21.9 595
4×25 rm 1.2 1.8 26 939
4×35 rm 1.2 1.8 29.3 1205
4×50 sm 1.4 1.9 29 1137
4×70 sm 1.4 2 33.2 1478
4×95 sm 1.6 2.1 36 2037
4×120 sm 1.6 2.3 40 2422
4×150 sm 1.8 2.4 43 2979
4×185 sm 2 2.5 48.2 3500
4×240 sm 2.2 2.7 54.2 4590
5×4 re 1 1.8 15.3 339
5×6 re 1 1.8 16.9 406
5×10 re 1 1.8 19 523
5×16 re 1 1.8 23.9 713
5×25 re 1.2 1.9 28.7 1148
5×35 re 1.2 2 32.5 1488

3. Contact information:
Any needs or question ,please contact us ,we will be more pleasure to service you.
We are looking forward to your inquiry and nice cooperaton.
 

Tags: , ,

Similar Or Related





Please enter your first and last name separated by a space (e.g. Jane Miller)




Success! Thanks for Your Request.
Error! Please Try Again.