AAC Conductor, All Aluminium Conductor (BS 215)
Product Description
AAC BS215 part1
AAC conductor is widely used in power transmission lines with various voltage levels.
Since they have such good characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical teatures exist.
1. Specification:
All aluminium conductor (AAC)
2. Elative manufacturing standards:
BS 215-1: Aluminium strander conductors
3. Construction:
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corrosion or infusion of the complete cable with grease.
Notes:
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.
Nominal cross sectional area | No of wires & wire diameter | Actual area | Overall diameter | Weight | Calculated breaking Load | Max d.c. resistance @20°C |
mm2 | mm | mm2 | mm | kg/km | kN | Ohm/km |
22 | 7/2.06 | 23.33 | 6.18 | 64 | 3.99 | 1.227 |
50 | 7/3.10 | 52.83 | 9.3 | 145 | 8.28 | 0.5419 |
60 | 7/3.40 | 63.55 | 10.2 | 174 | 9.9 | 0.4505 |
100 | 7/4.39 | 106 | 13.71 | 290 | 16.00 | 0.2702 |
150 | 19/3.25 | 157.6 | 16.25 | 434 | 25.70 | 0.1825 |
200 | 19/3.78 | 213.2 | 18.9 | 587 | 32.40 | 0.1349 |
250 | 19/4.22 | 265.7 | 21.1 | 731 | 40.40 | 0.1083 |
300 | 19/4.65 | 322.7 | 23.25 | 888 | 48.75 | 0.08916 |
400 | 37/3.78 | 415.2 | 26.46 | 1145 | 63.10 | 0.06944 |
- Next: E-Yy, Low Voltage Power Cable, 0.6/1 Kv, Cu/PVC/PVC (HD 603)
- Previous: Nay2y, Low Voltage Power Cable, 0.6/1 Kv, Al/XLPE/HDPE (DIN VDE 0276-603/HD 603)
Contact us
Similar Or Related
-
Aster Cable 366mm2 37 Strands AAAC Bare Conductor for 90kV HV Substation
-
AAAC Bare Conductor 100mm2 7/4.26mm for Uganda 33kV Distribution Line
-
AAAC Bare Conductor 50mm2 7/3.02mm for Uganda 11kV Distribution Line
-
Aerial Bundled Conductor 70mm2 Hard drawn Aluminum ABC Cable for 400V Distribution Line
-
50mm2;AAAC PVC Covered Hazel Conductor BS 3242 for 11kV Distribution Line