Bare Aluminium Conductor Steel Reinforced ACSR Conductor, Overhead Installation Stranded Aluminium Wire.
Product Description
Application of the products:
1. Aluminum-twisted is suitable for the common overhead power lines with the smaller distance and less force.
2. Aluminum-twisted with steel rush pith has characters such as simple structure, convenient to set up and maintain, lower cost, large transmitting volume, which is suitable for those special geographic conditions like astride the river or velley. Thus it is widely used in sorts of overhead power lines of different voltages.
3. Antiseptic aluminum-twisted with steel rush pith bears the better antiseptic features, suitable for those high, extra high voltage and common power lines set up over those coastal saltwater lakes, salt sand areas and industrial districts.
On the production of the aluminum-twisted with steel rush pith, we can fairly well distribute the antiseptic materials into the gaps between any two appointed levels on the customers’ request on different antiseptic grades.
Standard:
Can comply with IEC61089, ASTM B232, BS215, GB, DIN etc.
Construction:
According to IEC61089, cross section area of ACSR is from 16mm2 to 1250mm2, No of stranded aluminum wire and steel wire can be from Al6/1.84(mm)/Sr1/1.84 to Al84/4.35/Sr19/2.61.
Main feature:
Type: Bare
Conductor Type: Stranded
Application: Overhead Transmission Line
Conductor Material: Aluminum
Sheath Material: Bare
Insulation Material: Bare
Basic Information
Model No: ACSR Conductor
Material Shape: Round Wire
Range of Application: Overhead Installation
Certificate: ISO9001,ISO14001, CCC, CE
Brand Name: GDYG
HS Code: 7614100000
ACSR Code: Turkey, Swan, etc
ACSR Feature: Simple Construction, Easy Installation, Excellent Electric and Mechanical and Conductive etc
Specification: 10mm2 – 1500mm2
ACSR Conductor Advantage: Antiseptic Model.
Supply Record: African countries, Arabian countries, Asian countries etc.
Origin: Guangdong, China
IEC 61089
Code number | Steel Ratio | Areas | Number of wires | Wire diameter | Diameter | Linear mass | Rated strength | DC resitance | |||||
Aluminium | Steel | Total | Aluminium | Steel | Aluminium | Steel | Core | Conductor | |||||
% | mm2 | mm2 | mm2 | mm | mm | mm | mm | kg/km | kN | W/km | |||
16 | 17 | 16 | 2.67 | 18.7 | 6 | 1 | 1.84 | 1.84 | 1.84 | 5.53 | 64.6 | 6.08 | 1.7934 |
25 | 17 | 25 | 4.17 | 29.2 | 6 | 1 | 2.30 | 2.30 | 2.30 | 6.91 | 100.9 | 9.13 | 1.1478 |
40 | 17 | 40 | 6.67 | 46.7 | 6 | 1 | 2.91 | 2.91 | 2.91 | 8.74 | 161.5 | 14.40 | 0.7174 |
63 | 17 | 63 | 10.5 | 73.5 | 6 | 1 | 3.66 | 3.66 | 3.66 | 11.0 | 254.4 | 21.68 | 0.4555 |
100 | 17 | 100 | 16.7 | 117 | 6 | 1 | 4.61 | 4.61 | 4.61 | 13.8 | 403.8 | 34.33 | 0.2869 |
125 | 6 | 125 | 6.94 | 132 | 18 | 1 | 2.97 | 2.97 | 2.97 | 14.9 | 397.9 | 29.17 | 0.2304 |
125 | 16 | 125 | 20.4 | 145 | 26 | 7 | 2.47 | 1.92 | 5.77 | 15.7 | 503.9 | 45.69 | 0.2310 |
160 | 6 | 160 | 8.89 | 169 | 18 | 1 | 3.36 | 3.36 | 3.36 | 16.8 | 509.3 | 36.18 | 0.1800 |
160 | 16 | 160 | 26.1 | 186 | 26 | 7 | 2.80 | 2.18 | 6.53 | 17.7 | 644.9 | 57.69 | 0.1805 |
200 | 6 | 200 | 11.1 | 211 | 18 | 1 | 3.76 | 3.76 | 3.76 | 18.8 | 636.7 | 44.22 | 0.1440 |
200 | 16 | 200 | 32.6 | 233 | 26 | 7 | 3.13 | 2.43 | 7.30 | 19.8 | 806.2 | 70.13 | 0.1444 |
250 | 10 | 250 | 24.6 | 275 | 22 | 7 | 3.80 | 2.11 | 6.34 | 21.6 | 880.6 | 68.72 | 0.1154 |
250 | 16 | 250 | 40.7 | 291 | 26 | 7 | 3.50 | 2.72 | 6.16 | 22.2 | 1007.7 | 87.67 | 0.1155 |
315 | 7 | 315 | 21.8 | 337 | 45 | 7 | 2.99 | 1.99 | 5.97 | 23.9 | 1039.6 | 79.03 | 0.0917 |
315 | 16 | 315 | 51.3 | 366 | 26 | 7 | 3.93 | 3.05 | 9.16 | 24.9 | 1269.7 | 106.83 | 0.0917 |
400 | 7 | 400 | 27.7 | 428 | 45 | 7 | 3.36 | 2.24 | 6.73 | 26.9 | 1320.1 | 98.36 | 0.0722 |
400 | 13 | 400 | 51.9 | 452 | 54 | 7 | 3.07 | 3.07 | 9.21 | 27.6 | 1510.3 | 123.04 | 0.0723 |
450 | 7 | 450 | 31.1 | 481 | 45 | 7 | 3.57 | 2.38 | 7.14 | 28.5 | 1485.2 | 107.47 | 0.0642 |
450 | 13 | 450 | 58.3 | 508 | 54 | 7 | 3.26 | 3.26 | 9.77 | 29.3 | 1699.1 | 138.42 | 0.0643 |
500 | 7 | 500 | 34.6 | 535 | 45 | 7 | 3.76 | 2.51 | 7.52 | 30.1 | 1650.2 | 119.41 | 0.0578 |
500 | 13 | 500 | 64.8 | 565 | 54 | 7 | 3.43 | 3.43 | 10.30 | 30.9 | 1887.9 | 153.80 | 0.0578 |
560 | 7 | 560 | 38.7 | 599 | 45 | 7 | 3.98 | 2.65 | 7.96 | 31.6 | 1848.2 | 133.74 | 0.0516 |
560 | 13 | 560 | 70.9 | 631 | 54 | 19 | 3.63 | 2.18 | 10.90 | 32.7 | 2103.4 | 172.59 | 0.0516 |
630 | 7 | 630 | 43.6 | 674 | 45 | 7 | 4.22 | 2.81 | 8.44 | 33.8 | 2079.2 | 150.45 | 0.0459 |
630 | 13 | 630 | 79.8 | 710 | 54 | 19 | 3.85 | 2.31 | 11.60 | 34.7 | 2366.3 | 191.77 | 0.0459 |
710 | 7 | 710 | 40.1 | 759 | 45 | 7 | 4.48 | 2.99 | 8.96 | 35.9 | 2343.2 | 169.56 | 0.0407 |
710 | 13 | 710 | 89.9 | 800 | 54 | 19 | 4.09 | 2.45 | 12.30 | 36.8 | 2666.8 | 216.12 | 0.0407 |
800 | 4 | 800 | 34.6 | 835 | 72 | 7 | 3.76 | 2.51 | 7.52 | 37.6 | 2480.2 | 167.41 | 0.0361 |
800 | 8 | 800 | 66.7 | 867 | 84 | 7 | 3.48 | 3.48 | 10.40 | 38.3 | 2732.7 | 205.33 | 0.0362 |
800 | 13 | 800 | 101.0 | 901 | 54 | 19 | 4.34 | 2.61 | 13.00 | 39.1 | 3004.9 | 243.52 | 0.0362 |
900 | 4 | 900 | 38.9 | 939 | 72 | 7 | 3.99 | 2.66 | 7.98 | 39.9 | 2790.2 | 188.33 | 0.0321 |
900 | 8 | 900 | 75.0 | 975 | 84 | 7 | 3.69 | 3.69 | 11.10 | 40.6 | 3074.2 | 226.50 | 0.0322 |
1000 | 4 | 1000 | 43.2 | 1043 | 72 | 7 | 4.21 | 2.80 | 8.41 | 42.1 | 3100.3 | 209.26 | 0.0289 |
1120 | 4 | 1120 | 47.3 | 1167 | 72 | 19 | 4.45 | 1.78 | 8.90 | 44.5 | 3464.9 | 234.53 | 0.0258 |
1120 | 8 | 1120 | 91.2 | 1211 | 84 | 19 | 4.12 | 2.47 | 12.40 | 45.3 | 3811.5 | 283.17 | 0.0258 |
1250 | 8 | 1250 | 102.0 | 1352 | 84 | 19 | 4.35 | 2.61 | 13.10 | 47.9 | 4253.9 | 316.04 | 0.0232 |
1250 | 4 | 1250 | 52.8 | 1303 | 72 | 19 | 4.70 | 1.88 | 9.40 | 47.0 | 3867.1 | 261.75 | 0.0231 |