Aluminum Conductor/Aerial/Service Drop/ABC Cable with Round Wire
Product Description
ABC Cable; Service Drop Cable
The basic construction is as follows:
3 power cores consisting of standard aluminium conductors, insulated with
XLPE insulation
+ One sheath lighting aluminium conductor with XLPE insulation (optional)
+ One messenger Al-alloy conductor (bare or covered)
The messenger conductor can be of galvanised steel wire also.
The purpose of messenger wire is
A) It acts as load bearing wire.
B) It acts as earth or neutral conductor.
To be used at cotages of 600V phase-to-phase or less and at conductor temperatures not to exceed 75oC for polyethylene insulated conductors or 90oC for crossliked polyethylene(XLPE) insulated conductors.
It meets or exceeds the following specifications:
1. Aluminum Wire, 1350-H19 for Electrical Purposes.
2. Aluminum Conductors, Concentric-Lay-Stranded.
3. Aluminum Conductor, Concentric-Lay-Stranded, Coated Steel Reinforced(ACSR)
4. Concentric-Lay-Stranded 6201-T81 Conductors
5. Compressed Round Stranded Aluminum Conductors Using Single Input Wire.
Technical Data
Maximum operating temperature 90 degree
Maximum short-circuit temperature 250 degree. Service drop( ABC cables) are especially used at areas where the cost of underground networks is expensive and also for electrification of rural areas like villages.
SPEC mm2 | conductor structure | Approx. | ||||||
Phase | Neutral(Bare ACSR) | insulation | insulation | Overall | Approx. | packing | ||
(Compacted AL) | Aluminium | Steel | material | Thickness | Diameter | Weight | Meters Per | |
(No./mm) | (No./mm) | (No./mm) | (mm) | (mm) | (kg/km) | Drum | ||
1×16+1×16 | 7/1.72 | 6/1.72 | 1/1.72 | XLPE | 1.2 | 12.5 | 121.9 | 250-4000m |
1×25+1×25 | 7/2.15 | 6/2.15 | 1/2.15 | 1.2 | 14.9 | 182.2 | 250-4000m | |
1×35+1×35 | 7/2.54 | 6/2.54 | 1/2.54 | 1.4 | 17.5 | 254.7 | 250-3500m | |
1×50+1×50 | 7/2.92 | 6/2.92 | 1/2.92 | 1.4 | 20.1 | 333.9 | 250-3000m | |
1×70+1×70 | 19/2.15 | 12/2.15 | 17/2.15 | 1.4 | 23.6 | 382.2 | 250-3000m | |
1×95+1×95 | 19/2.54 | 12/5.24 | 17/5.24 | 1.6 | 27.6 | 528.2 | 250-3000m | |
2×16+1×16 | 7/1.72 | 6/1.72 | 1/1.72 | (HDPE) | 1.2 | 14.2 | 187.6 | 250-4000m |
2×25+1×25 | 7/2.15 | 6/2.15 | 1/2.15 | 1.2 | 16.7 | 273.8 | 250-3500m | |
2×35+1×35 | 7/2.54 | 6/2.54 | 1/2.54 | 1.4 | 19.7 | 386.9 | 250-3500m | |
2×50+1×50 | 7/2.92 | 6/2.92 | 1/2.92 | 1.4 | 22.5 | 506 | 250-3000m | |
2×70+1×70 | 19/2.15 | 12/2.15 | 7/2.15 | 1.4 | 26.1 | 617.2 | 250-3000m | |
2×95+1×95 | 19/2.54 | 12/5.24 | 7/5.24 | 1.6 | 30.5 | 850.9 | 250-3000m | |
3×16+1×16 | 7/1.72 | 6/1.72 | 1/1.72 | 1.2 | 16.3 | 253.3 | 250-3500m | |
3×25+1×25 | 7/2.15 | 6/2.15 | 1/2.15 | 1.2 | 19.1 | 371.9 | 250-3500m | |
3×35+1×35 | 7/2.54 | 6/2.54 | 1/2.54 | 1.4 | 22.5 | 519.1 | 250-3000m | |
3×50+1×50 | 7/2.92 | 6/2.92 | 1/2.92 | 1.4 | 25.7 | 678.1 | 250-3000m | |
3×70+1×70 | 19/2.15 | 12/2.15 | 7/2.15 | 1.4 | 29.7 | 1024.3 | 250-3000m | |
2×95+1×95 | 19/2.54 | 12/2.54 | 7/2.54 | 1.6 | 34.6 | 1413.7 | 250-3000m |
It meets or exceeds all applicable requirements of ANSI/ICEA S-76-474
Company
Contact us
Similar Or Related
-
200 Sqmm. Stranded Aluminum Conductor Steel Reinforced (ACSR) Panther 200 MMSQ
-
ACSR 240/40 Aluminum Conductor Steel Reinforced Bare Conductor for Busbar Connection
-
ACSR 490/65 Aluminum Conductor Steel Reinforced Bare Conductor for Busbar Connection
-
100 mm2 Stranded Aluminum DOG Conductor Steel Reinforced (ACSR)
-
ACSR 305/40 Aluminum Conductor Steel Reinforced Bare Conductor for Busbar Connection
-
Aluminum Conductor/Aerial/Service Drop/ABC Cable with Round Wire