18/46 Kv 16mm Yjv Xple Electrical Power Cable Price with Lu ISO CCC

18/46 Kv 16mm Yjv Xple Electrical Power Cable Price with Lu ISO CCC

18/46 Kv 16mm Yjv Xple Electrical Power Cable Price with Lu ISO CCC

YJV VV VV32 YJV32

Yifang

ISO9001, CE, UL, CCC, RoHS

Construction

Round Wire

XLPE

PVC

Copper or Aluminum

Underground, Power Trandmission and Distribution Line

Stranded

Insulated

1 or 3

Black ,Blue or According to Customers' Request

Semi-Conducting Compound

PVC / PE / LSZH

Yifang

Drum, Reel or According to Customers' Request

IEC, BS, DIN, ASTM, JIS, GOST, ETC

Zhengzhou, Henan, China

8544492100

Product Description

MV XLPE Insulated Aromoured Power Cable 1core or 3 core

1. Brief Introduction of XLPE Insulated Power Cable

Cross-linked polyethylene insulated power cable not only has excellent electric, mechanical properties,But also has powerful resistance against chemical corrosion, heat aging and environmental stress. Its structure Is simple. The long term operating temperature is 90. It is convenient to use and can be laid with no Restriction of different level.

Our enterprise can produce both flame retardant and non-flame retardant series of XLPE power cable.

Our XLPE Power cable covers all kinds of low-smoke low-halogen, low-smoke halogen free and three
Classes of A, B, C.

We can design and manufacture special XLPE cable according to the other standards required by the Customers, such as Heavy section cut apart conductors, water-resistance, defend termites, defend mouse, And so on.

2. Scope of our Cables

The rate voltage cables in the 1st class available To the earth fault time within 1 minute. The cables In the 2nd class are available to earth fault time not Exceeding 2 hours generally, maximum time doesn’t Exceed 8 hours.

3. Service Conditions and Parameters of Cable

Conductor:IEC 60228 class 1 class 2 bare copper / aluminum etc
Shield:copper wire / copper tape / AL- plastic tape
Max. Conductor Operating Temperature: 90
Short Circuit Temperature: 250 Not more than 5 seconds
Environmental temperature of operating: In air: 40
Depth of laying in direct: 80cm
Thermal Resistance of soil: 100. Cm/W
Armoured (optional):Galvanized steel wire / aluminum wire / two layers of aluminum tape gap-wrapped / two layers of steel tape gap-wrapped / gavanized steel interlocked armour / aluminum alloy interlocked armour

4.Production Scope

A:National standard

Rated Voltage(KV) 3.6/6 6/6 6/10 8.7/10 8.7/15 12/20 18/20 18/30 21/35 26/35
Core Number 1 core or 3 cores
Cross section mm2 1C 25-800 35-800
3C 25-400 35-400

B:IEC/BS/GB standard

Rated Voltage(KV) 3.6/6 3.8/6.6 6/10 6.6/11 8.7/15 12/20 12.7/22 15/20 15/25 18/30 19/33 20.8/36
Core Number 1 core or 3 cores    
Cross section mm2 1C 25-800 35-800    
3C 25-400 35-400    

C:ICEA standard

Rated Voltage(V) 5001/800 8001/15000 15001/25000 25001/28000 28001/35000 35000/46000
Core Number 1 core or 3 cores
Cross section AWG orkcmil 1C 6 AWG~1600 kcmil 2 AWG~1600 kcmil 1 AWG~1600 kcmil 2 AWG~1600 kcmil 1/0 AWG~1600 kcmil
3C 6 AWG~800 kcmil 2 AWG~800 kcmil 1 AWG~800 kcmil 2 AWG~800 kcmil 4/0 AWG~800 kcmil

Tags: , ,