0.6/1kv Low Voltage PVC Insulated Steel Tape Armoured Cable

0.6/1kv Low Voltage PVC Insulated Steel Tape Armoured Cable

0.6/1kv Low Voltage PVC Insulated Steel Tape Armoured Cable

VV22, VLV22

Construction, Underground, Industrial, Power Station

Low and Medium Voltage Cable

DC Cable

PVC

PVC

Round Wire

Copper or Aluminum

ISO

VV22,Vlv22

Jytop

4 Core, 3+1 Core

ASTM, AS/NZS, BS, CSA, DIN, IEC…

Ce, ISO 9001

0.6/1kv

Black,Red,Yellow,Blue,Brown,Green

JYTOP

Reel or Drum

any Third party Pre-shipment inspection

Zhengzhou, China

8544492100

Product Description

0.6/1KV Low Voltage PVC Insulated Steel Tape Armoured Cable

1. Operating Characteristics
Rated voltage: 0.6/1(1.2)kV
Max. Permissible continuous operating temperature of conductor: 70° C
Max. Temperature of conductor during short-circuit (5s max. Duration) shall not exceed:
Nominal cross section of conductor ≤ 300mm2: 160 ° C
Nominal cross section of conductor >300mm2: 140 ° C
The ambient temperature under installation should not be lower than: 0 ° C
The bending radius of cable is recommended as following:
For single core cable: Not less than 15 times of the diameter of cable
For multi-core cable: Not less than 12 times of the diameter of cable
When the armored single core cable used for Alternative Current(AC) system, the armoring material should be non-magnetic.


2. Application
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, in tunnel, in cable trench or direct in ground, able to bear external mechanical force, but unable to bear large pulling force.

3. Manufacturing Standards
IEC 60502-1 & Chinese national standard GB/T 12706-2008 We can produce above cables according to popular international standards such as ASTM, BS, DIN, NF &AS/NZ also.

KINDLY NOTE: If you want to know more details about this kind of products, please visit our website:jytopcable for further information. Thanks.

Note: RE= round conductor RM = stranded conductor SM=sectional conductor

Cable size Conductor type Nominal thickness of PVC insulation(mm) Nominal
thickness
of steel tape(mm)
Nominal
thickness
of PVC
sheath
(mm)
Approx. cable
overall diameter (mm)
Max. D.C resistance @ 20 0 C (Ω/km)
Phase
core
Earth
core
Phase
core
Earth
core
Phase
core
Earth
core
3×2.5+2×1.5mm 2 RE RE 0.8 0.8 0.2 1.8 16.2 7.41 12.1
3×4+2×2.5mm 2 RE RE 1.0 0.8 0.2 1.8 17.3 4.61 7.41
3×6+2x4mm 2 RE RE 1.0 1.0 0.2 1.8 18.6 3.08 4.61
3×10+2x6mm 2 RM RE 1.0 1.0 0.2 1.8 20.4 1.83 3.08
3×16+2x10mm 2 RM RM 1.0 1.0 0.2 1.8 22.7 1.15 1.83
3×25+2x16mm 2 SM RM 1.2 1.0 0.2 1.8 28.4 0.727 1.15
3×35+2x16mm 2 SM RM 1.2 1.0 0.2 1.8 30.3 0.524 1.15
3×50+2x25mm 2 SM SM 1.4 1.2 0.5 2.0 34.6 0.387 0.727
3×70+2x35mm 2 SM SM 1.4 1.2 0.5 2.1 38.5 0.268 0.524
3×95+2x50mm 2 SM SM 1.6 1.4 0.5 2.3 43.7 0.193 0.387
3×120+2x70mm 2 SM SM 1.6 1.4 0.5 2.4 48.1 0.153 0.268
3×150+2x70mm 2 SM SM 1.8 1.4 0.5 2.5 50.9 0.124 0.268
3×185+2x95mm 2 SM SM 2.0 1.6 0.5 2.7 56.3 0.0991 0.193
3×240+2x120mm 2 SM SM 2.2 1.6 0.5 2.9 62.1 0.0754 0.153
3×300+2x150mm 2 SM SM 2.4 1.8 0.5 3.1 67.9 0.0601 0.124