0.6/1kv Armored Cable 3X120mm Aluminum Cable with Steel Tape Armored

0.6/1kv Armored Cable 3X120mm Aluminum Cable with Steel Tape Armored
armored cable 3x120mm
Construction, Underground, Industrial, Power Station
Low and Medium Voltage Cable
DC Cable
XLPE
PVC
Round Wire
Aluminum
ISO, CCC, CE
YJLV22
Jytop
Black,Red,Yellow,Blue,Brown,Green
70mm 95mm 120mm 150mm
0.6/1kv
Armored Cable 3X120mm
Aluminum Cable 3X120mm
Armored Cable 3X120mm
CE,ISO 9001
Power Cable Manufacturer
Henan
IEC 60502
JYTOP
Packed in Reels
as per popular standards or clients's requirement
Zhengzhou, China
8544492100

Product Description

Low Voltage 0.6/1kv Aluminum Conductor XLPE Insulated Steel Tape Armored Power Cable

1. Operating Characteristics
Rated voltage: 0.6/1(1.2)kV
Max. Permissible continuous operating temperature of conductor: 90 ° C
Max. Temperature of conductor during short-circuit (5s max. Duration) shall not exceed: 250 ° C
The ambient temperature under installation should not be lower than: 0 ° C
The bending radius of cable is recommended as following:
For single core cable: Not less than 15 times of the diameter of cable
For multi-core cable: Not less than 12 times of the diameter of cable
When the armored single core cable used for Alternative Current(AC) system, the armoring material should be non-magnetic.

2. Application
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, in tunnel, in cable trench or direct in ground, able to bear external mechanical force, but unable to bear large pulling force.

3. Manufacturing Standards
IEC 60502-1 & Chinese national standard GB/T 12706-2008 We can produce above cables according to popular international standards such as ASTM, BS, DIN, NF &AS/NZ also.

NOTE:
If you want to know more details about this kind of products, please visit our website(homepage) because we have no ways to show so much information on this platform. Thank you.

Cable size Conductor type Nominal thickness of XLPE insulation (mm) Nominal
thickness
of steel
tape(mm)
Nominal thickness of PVC or PE sheath(mm) Approx. cable overall diameter (mm) Max. D.C resistance @ 20 0 C (Ω/km)
3×1.5mm 2 RE or RM 0.7 0.2 1.8 13.0 18.1
3×2.5mm 2 RE or RM 0.7 0.2 1.8 13.8 12.1
3x4mm 2 RE or RM 0.7 0.2 1.8 14.8 7.41
3x6mm 2 RE or RM 0.7 0.2 1.8 15.9 4.61
3x10mm 2 RM 0.7 0.2 1.8 18.7 3.08
3x16mm 2 RM 0.7 0.2 1.8 21.0 1.91
3x25mm 2 SM 0.9 0.2 1.8 20.7 1.20
3x35mm 2 SM 0.9 0.2 1.8 22.6 0.868
3x50mm 2 SM 1.0 0.2 1.9 25.2 0.641
3x70mm 2 SM 1.1 0.5 2.0 30.5 0.443
3x95mm 2 SM 1.1 0.5 2.1 34.2 0.320
3x120mm 2 SM 1.2 0.5 2.2 37.2 0.253
3x150mm 2 SM 1.4 0.5 2.4 40.9 0.206
3x185mm 2 SM 1.6 0.5 2.5 45.0 0.164
3x240mm 2 SM 1.7 0.5 2.7 50.2 0.125
3x300mm 2 SM 1.8 0.5 2.9 55.1 0.100